39
Effective 11/1/07, Revised 1/1/09, Revised 8/1/09
Unique
PMO
Plus
®
Series Sanitary Mixproof Valve Instruction Manual
Valve Seat Position Indication
The following instructions can be completed while the valve is at room (ambient)
temperature.
1. Enter new 'UPPER SEAT LIFT' position data to the
Think
Top memory in step 5 of the
programming sequence using the 'I' and 'II' keys.
Note: Data entry is done with the valve deactivated (Closed).
2. Adjust lateral sensor per instructions for 'UPPER VALVE SEAT EXTERNAL SENSOR' in
this section.
Refer to "Electrical Connections/Instructions" in this manual for
Think
Top programming.
Adjustments
Upper Valve Seat
Think
Top
(Set Position New on
Think
Top)
Adjustments
Lower Valve Seat
Think
Top
The following instructions can be completed while the valve is at room (ambient)
temperature.
1. Delete the current 'CLOSED VALVE" position data from the
Think
Top memory using the
'I' and 'II' keys.
2. Enter new 'CLOSED VALVE' position data to the ThinkTop memory using the 'I' and 'II'
keys.
3. Repeat 'Test - 2, Lower Valve Seat Position Detection' procedures to conirm
adjustment.
Refer to "Electrical Connections/Instructions" in this manual for
Think
Top programming.