6 Setup diagram
6.1
ThinkTop
®
setup utilising IR keypad
General
Flashing LED means no value set. Steady LED means value set as shown.
Default:
Step 2, factory-set tolerance band +/- 5 mm
Step 3-8, disabled
D LED:
Active during set-up:
Flashing in step 1
Steady in all other steps
Or during operations, error condition:
Steady showing hardware fault, indication pin out of range
Flashing showing software fault
Timeout:
A 60 sec. timeout is started as soon as any button(s) are released
On timeout the setup is exited with no changes saved
IR Keypad:
Remote distance 0-300 mm to ThinkTop
®
Symbols
X
Push key on IR keypad with the same number
Simple representation of LED indication:
Yellow
B
IR-Reciver
Red
D
Steady LED
Yellow
C
Green
E
Orange
F
Yellow
A
Flashing LED
G
General commands in each step (except step 1):
0
Next step / skip step
(In step 3-6 the program automatically moves to the next step
when a position is stored)
5
Clear / disable step
(In step 2 this resets the unit and sets the step 2-8 to default)
(The command is accepted when all unit LED’s flash briefly)
IIt is recommended to reset the unit before
performing a setup.
Always check for correct signals after the setup.
20