Operating Manual
PUMP MODEL
PORT SIZE
DISPLACEMENT
MAXIMUM DISCHARGE
MAXIMUM
PRESSURE
SPEED
in
mm gal/100rev l/100rev
lbf/in²
bar
rpm
N1-000S-H07
¼
6
0.45
2.05
100
7
1000
N1-000L-H07
½
12
0.85
3.86
100
7
1000
1
25
10.2 Lubrication
Pumps are to be filled with 0.3 litres of oil prior to operation with the recommended oil grades as
follows:
BP Energol GR-XP150
Castrol Alpha SP150
Mobil Gear 629
Shell Omala 150
Texaco Meropa 150
Esso Spartan EP150
Oil Filling
Fill with oil through the filler plug on top of the gearbox to the level plug on the side of the
gearbox.
Oil Changing
The oil must be changed with the pump static.
First change should be after 150 hours of operation, thereafter every 3000 hours of operation or a
period of 2 years, whichever is the soonest.
10.0 Technical Data
10.1
Pump Information Chart
The following table details technical data
regarding the pump range, for further details
contact your supplier.