Recommended Olis:
Food Grade Oil (NSF H-1)
-20
o
C to +150
o
C (-4
o
F to 302
o
F)
Mobil SHC Cibus 150
Bel-Ray No-Tox HD 150 #62686
Castrol Optileb GT 150
Klüber Klüberoil 4 UH1-150 N
Fusch Cassida GL / GLE 150
Mobil Glygole 150 (US/CAN)
All oils are poly-alpha-olefin based please check compatibility before mixing with other base oils.
Baseplate Foundations
Pumps when supplied with a drive unit are normally mounted on a baseplate. Alfa Laval standard
positive displacement pump baseplates have pre-drilled fixing holes to accept base retaining bolts. To
provide a permanent rigid support for securing the pump unit, a foundation is required which will also
absorb vibration, strain or shock on the pumping unit. Methods of anchoring the baseplate to the
foundation are varied, they can be studs embedded in the concrete either at the pouring stage as
shown below, or by use of epoxy type grouts. Alternatively, mechanical fixings can be used.
Ensure the floor is able to support the weight of the pump unit.
D
min
3D
D
a
b
3206-0010
0
.5
D
mi
n
c
4D
3206-0011
1
0
D
a
a Sleeve
b Lug welded to bolt head
c Waste put around bolt before pouring concrete
a Foundation surface left through to anchor ground
The drawing above shows two typical methods for foundation bolt retaining. The sleeve allows for
“slight” lateral movement of the bolts after the foundation is poured. Rag or wastepaper can be used
to prevent the concrete from entering the sleeve while the foundation is poured. A minimum of 14
days is normally required to allow the curing of the concrete prior to pump unit installation.
200002348-1-EN-GB