6
Seal fitting
NOTE
Ensure all screws and nuts are torqued to the
values stated in Section 6.
1.
Apply a small amount of suitable
lubrication to the new lip seal (111) and
press fit to the rear seal bore of the
rotorcase (2) until flush with end of bore.
2.
Refit the rotorcase ensuring the rotor case
screws (11) are torques to tightening the
rotorscrews to the required torque setting
as shown in Section 6.
3.
Follow instructions 1. to 9. as for the
single seal assembly.
4.
Refit the flush pipework and refill,
checking for any leaks and correct
operation before restarting the pump.
3206-0078
200002348-1-EN-GB