3. OPERATING CONDITIONS 

1.  Putting  the  machine  into  operation  can  be  performed  only  by  trained 

personnel and only within the technical provisions. The manufacturer is not 
liable  for  damages  resulting  from  improper  use  or  handling.  For 
maintenance and repair, use only original spare parts from ALFA IN. 

2.  Device  complies  with  IEC  61000-3-12  with  following  conditions: 

Short-circuit  power  S

sc

  of  network  in  place  at  an  interface  between  the 

user's  supply  and  the  public  network  (PCC)  must  be  least  4106  kW. 
User is obliged to consult with the electricity supplier if the impedance of 
the network at this point is that required short-circuit capacity Z

max 

= 36 mΩ 

and  whether  the  device  can  be  connected  with  a  public  low-voltage 
network. 

On the nameplate are the following symbols: 

3.  The  welding  machine  is  tested  according  to  the  degree  of  protection  IP 

23S, which provides protection against the intrusion of solid bodies with a 
diameter  greater  than  12  mm  and  protection  against  ingress  of  water, 
falling on the machine in a vertical direction or max degree of 60°. 

4.  Working ambient temperature between -10 and +40 °C. 
5.  Relative humidity below 90% at +20 °C. 
6.  Up to 3000 m altitude. 
7.  The machine must be positioned so that cooling air can enter and leave 

through cooling vents with no problem. It is necessary to ensure that there 
are  no  mechanical  equipment,  especially  metal  particles  (e.g.  during 
grinding) drawn into the machine.  

8.  Handling handle is intended for movement, it is not designed to lifting the 

machine. 

9.  In  case  of  overheating  of  the  machine  welding  is  automatically  stopped 

and this condition is signalized by pilot light. 

10. 

All interventions in the el. equipment as well as repair (removal of the 

plug, fuse replacement) should be performed by an authorized person.   

11. 

With competent mains voltage and input must match the plug. 

12. 

Do not use the machine for other purposes, such as defrosting pipes, 

starter source, etc. 

13. 

It is necessary for welding machine to undergo a periodic inspection 

every 6/12 months by an authorized officer according to ČSN 331500 and 
ČSN 050630 – see Maintenance and service tests. 

14. 

The welding machine is designed especially for industrial areas. In 

case of using it in other areas there may exist special measures (see EN 
60974-10). 

15. 

It is necessary to protect the machine against: 

a.  Moisture and rain 
b.  Mechanical damage 
c.  Draft and possibly ventilation of neighboring machines 
d.  Excessive overloading – exceeding tech. parameters 

Содержание aXe 250 mobil GAS

Страница 1: ...ALFA IN a s www alfain eu aXe 250 320 PULSE MOBIL AL manual EN 08 WELDING MACHINES aXe 250 PULSE mobil AL GAS aXe 320 PULSE mobil AL GAS aXe 250 mobil GAS aXe 320 mobil GAS INSTRUCTION MANUAL...

Страница 2: ...4 TECHNICAL DATA 6 5 ACCESSORIES 8 6 DESCRIPTION OF THE APPLIANCE 9 7 BASIC SETTINGS 15 8 MIG MAG WELDING SYNERGY 22 9 PULSED MODE 23 10 MIG MAG WELDING MANUAL 24 11 MMA WELDING COATED ELECTRODE ELE...

Страница 3: ...ld different types of connections blunt single sided double sided fillet lap etc using wire diameter from 0 6 0 8 mm or 1 0 1 2 mm of different metals and alloys carbon and alloy steels aluminum alloy...

Страница 4: ...resh air because during welding harmful fumes arise 5 In tanks of gas oil fuel etc even empty ones do not make welding because there is a chance of explosion 6 In areas with chance of explosion specia...

Страница 5: ...lative humidity below 90 at 20 C 6 Up to 3000 m altitude 7 The machine must be positioned so that cooling air can enter and leave through cooling vents with no problem It is necessary to ensure that t...

Страница 6: ...ll as the radiated interference During operation the device may be the source of interference Caution We warn users that they are responsible for possible interference from welding 4 TECHNICAL DATA Mo...

Страница 7: ...15 20 300 Protection IP 23S Standards EN 60974 1 EN 60974 10 cl A Dimensions w x l x h generator mm 240 x 650 x 438 Weight generator compact kg 26 6 Wire speed m min 1 0 16 0 Spool diameter mm 300 Spo...

Страница 8: ...3 Rolls 0 6 0 8 and 1 0 1 2 with different grooves 4 Torch PARKER SGA LW305A Ultralight 3 m 5 m 5 Torch PARKER DIGIMIG 305 aXe IN UD Ultralight 3 m 5 m 6 Torch PARKER SGB 240W d lka 3 m 5 m 7 Torch P...

Страница 9: ...9 30 ALFA IN a s www alfain eu 6 DESCRIPTION OF THE APPLIANCE MAIN PARTS Fig 1 Main parts of the machine...

Страница 10: ...A7 Spool holder A8 Soneloid valve A9 Mains cable A10 Button of inserting the wire A11 LED B1 EURO connector B2 EURO connector male B3 Torch C1 Quick connector male C2 Earthing clamps C3 Quick connect...

Страница 11: ...welding wire Only this way a smooth wire feed can be achieved Irregularities of the wire feed leads to a poor quality of welding and deformation of the wire A B C Fig 3 The influence of the roll groov...

Страница 12: ...AIMg3 or AlMg Wire of alloy Al99 5 or AlSi5 are too soft and easily will cause problems with movement For the aluminum welding it is also necessary to provide the torch tefl liner and special current...

Страница 13: ...essary the brake can be adjusted by a screw D1 so that while stopping the feed spool will be stopped on time it will avoid excessive release of wire However too tight brake needlessly strains the feed...

Страница 14: ...perfectly shielded by gas Too small amount of gas does not perform the protective atmosphere and on the other hand to big amount of the gas brings air into the electric arc Notice Gas bottle must be...

Страница 15: ...TTINGS CONTROL PANEL Fig 7 Control panel Pos Description V1 Button Gas test V2 Button Pulsed mode V3 LED If it illuminates when Pulsed mode was chosen V4 Instant JOB buttons 1 6 V5 Current encoder V6...

Страница 16: ...he encoder V5 choose the method ELE covered electrode MMA MAN MIG MAG manual or SYN MIG MAG synergistic Confirm your choice by pressing the button V5 WELDING METHOD SYNERGY Synergic curves are welded...

Страница 17: ...t to confirm 4 Unscrew the gas nozzle of the welding torch 5 Cut off the welding wire tightly at the welding jet 6 Piece of the welding wire about 50 mm give to the wire feeder In the current jet cann...

Страница 18: ...V20 to switch between the modes 2T 4T and The two stroke stairs mode is signalized by LEDs V17 and V19 First tact press and hold the torch button the machine will start welding with the Start current...

Страница 19: ...ts Fig 8 Curves of modes SECONDARY PARAMETERS MENU From start the welding machine is set to factory settings default For most of the work it is not appropriate to change the secondary parameters Secon...

Страница 20: ...1 s 2 t E Time END Time of end current 0 1 10 0 s 0 1 s 2 CAL Calibration menu Calibration menu x xx version sw PCB engine The last menu item is CAL it is used to enter the calibration menu which is...

Страница 21: ...hoke JOB H4 Torch button LOCK lock unlock the buttons UP DOWN and M The UP DOWN and M buttons get automatically locked when the torch trigger is pressed H5 When the LED is on it indicates UP DOWN and...

Страница 22: ...efault parameters will be restored 2 It will delete saved JOBs 8 MIG MAG WELDING SYNERGY 1 Choose SYN method see SETTING THE METHOD OF WELDING 2 Left display V10 shows machine output current wire feed...

Страница 23: ...at stated synergic programs 2 If is the pulsed mode switched on LED V3 at the button V2 shines 3 Left display V10 shows machine output current wire feed speed material thickness right display V11 sho...

Страница 24: ...tons H6 UP and H7 DOWN set the displayed value with the button MODE swith between functions If is activated the JOB choice by the remote control you can switch between JOBs WELDING VOLTAGE It is set u...

Страница 25: ...1 m wire g Wire consumption per 1 minute of welding g min Wire consumption per 1 hour of welding g hour Steel wire 0 6 2 5 5 2 3 11 5 690 0 8 3 6 6 4 24 1440 1 0 3 12 12 6 72 4320 1 2 4 18 18 9 162 97...

Страница 26: ...d g s 1 6 30 55 300 4 35 0 11 2 5 70 110 350 11 49 0 22 3 2 90 140 350 19 60 0 32 4 0 120 190 450 39 88 0 44 12 ROUTINE MAINTENANCE INSPECTION 1 The only routine maintenance required for the aXe range...

Страница 27: ...display V10 shows Err the right display V11 shows number marking of the error Err 1 Overheating of the machine DO NOT POWER OFF THE MACHINE Err noP Pulsed mode cannot turn on for the selected synergic...

Страница 28: ...ate supply of a protective gas pores in the weld Poorly set the amount of supplied gas Set the correct amount as described in this instruction manual Reducing valve on the bottle is dirty Check and re...

Страница 29: ...er 4 If warranty is being sought please contact your ALFA IN product supplier for the warranty repair procedure 5 ALFA IN warranty will not apply to a Equipment that has been modified by any other par...

Страница 30: ...in accordance with national law electric tools that have reached the end of their service life must be collected separately and returned to an environmentally compatible recycling facility 15 WARRANTY...

Отзывы: