- 25 -
ALFA IN a.s. ©
www.alfain.eu
8.3 SECONDARY PARAMETERS
If necessary it is possible to change the secondary parameters:
Initial wire speed (soft start)
ISP
Pre gas time
PrG
Post gas time
PoG
Burn back time
brn
Time of spots (tack or interval welding)
SPo
Time of intervals (interval welding)
Int
Press buttons X3 and X5 at the same time for at least.
On left display will appear ISP. On the right display will appear value of the
chosen parameter.
By means of the Encoder you can change the parameter.
Use the button X3 to select the next parameter. When you press the button
X3, the value of the previous parameter had been stored.
8.4 SYNERGY MODE (ONLY FOR THE SYNERGY MODELS)
Synergy machines can advise the welder the optimum settings. Please keep
in mind that those machines are not equipped with incremental sensors and
therefore the advised settings are always approximate (+/- 1÷3 steps on the
fine voltage step).
It depends also on welding position, kind of welding wire, gas and mains
voltage.
The optimal setting has been determined for welding position PA.
The welder select the parameter that he knows by means the button X5
and the encoder X20 (Current in A, wire speed in m/min or material
thickness). Then the welder can the recommended settings see on the right
display (see Fig. 17).