5 Technical Specifications
SPOT Model
SPOT 600/1000
SPOT 1500
Input
MPPTs/Inputs per SPOT (Standard)
4
Maximum String Voltage
1000 V
1500 V
String Operating Voltage
200 – 1000 V
300 – 1425 V
MPPT Voltage Range
250 – 880 V
350 - 1350 V
Maximum Current Per Input @ 25 C
25 A
18.5 A
Reverse Polarity Protection
Yes
Max. Input Power per Input @ 25 C
22 KW
20 kW
Max. Input Power per Input @ 50 C
16.94 KW
15 kW
Grounding Configuration
Positive, Negative or Floating
Output
Output Operating Voltage
Fully Configurable from 200 to 1500 V
Max Number of Outputs
4
Reverse Polarity Protection
Yes
Grounding Configuration
Floating
Efficiency
Peak Efficiency
98.5%
CEC Weighted Efficiency
98%
Standards & Compliance
Certifications
UL1741, IEC 62109-1, CSA C22.2
Environmental
Storage Temperature
-40°C to 85°C
Cooling
Natural Convection or Forced Air
Environmental Rating
NEMA 3R & IP 66