Troubleshooting

Have a multimeter to check voltage and continuity. Use caution when checking high voltage terminals.

Maintenance

Every six months check the following items for proper operation of the unit.

* Lubricate shafts and sprockets.

* Keep operator clean at all times.

* Check and tighten anchors bolts.

* Check for loose or corroded wire

* Ensure the operator is well earthed, and correctly terminated.

* Always check the Stop/Reverse in case of obstruction function when performing any maintenance. If

this  function can’

t be made operable, remove this operator from service until the cause of the

malfunction is identified and corrected.

Symptom

Possible Solution(s)

The  remote  control 

does  not  emit  any 

single

Check the batteries are exhausted, replace them if necessary.

The  operator  doesn’

run.

1. Make sure that the power cord is properly plugged into the mains outlet.

2.  Check  the  fuse  is  blown  in  the  control  board;  if  necessary,  identify  the 

reason for the failure and then replace a new one. 

3.  Make  sure  the  photocell  beam  is  not  blocked  if  the  photocell  is  used.

Check the terminal 11 should be shorted with terminal 12 by a jumper wire. 

Please reset this jumper wire if it is loss. 

The gate starts but it is 

immediately  stop  or 

reverse

1. The selected force is too small to move the gate. Turn the Potentiometer

clock-wise to increase the force.

2. Disconnect the gate from the gate operator and check that the gate slides 

freely without any binding.

Содержание AC 1500

Страница 1: ...REV 13E www WholesaleGateOpener com...

Страница 2: ...lation of the Opener 6 Manual Operation 7 Installation of chain and chain brackets 7 Installation of Magnets for Limit Switches 9 Connecting Of Power Supply 10 Connecting of the Control Board 10 Setti...

Страница 3: ...before carrying out any work on the installation Also disconnect any buffer batteries if fitted Fit an omnipolar or magnetothermal switch on the mains power supply having a contact opening distance eq...

Страница 4: ...es not bind or drag on the ground The gate manual operation can be carried out smoothly along its entire run and there is no excessive side slipping The opening and closing gate stops are positioned W...

Страница 5: ...4 Parts List...

Страница 6: ...eed 15 cm second Max gate weight 600KGS 1500LBS 1000KGS 2400LBS Max torque 12Nm 24Nm Environmental conditions From 15 C to 40 C Protection class IP44 Dimensions 25 2 22 25 CM Features Midway mode Quic...

Страница 7: ...e movement of the gate and there is no danger of derailment Ensure that the safety side panels are present Necessary Tools The following tools may be necessary to install the Gate opener You will need...

Страница 8: ...The opener should be put in the manual emergency release position before fitting the rack installing the opener and limit switch The process is as follows 1 Take off the rubber stopple 2 Insert the R...

Страница 9: ...x the base plate by tightening the washers and nuts 7 Insert the opener shaft into the drive sprocket of chain box Mount the opener by tightening the bolts and washers 8 Fix the chain box by tightenin...

Страница 10: ...fully open by hand Locate and install the magnet bracket so that the opener will stop at the desired open position when the open limit switch approaches it The magnet component with N pole outside mu...

Страница 11: ...ect the live wire and neutral wire to the L 2 and N 1 terminal respectively and connect the earth wire to PE Connecting Of the Control Board 1 Motor The BLACK wire of the motor should be connected int...

Страница 12: ...inal the NC terminal to the 12 terminal 5 Wired Keypad 24VDC The RED wire of the wired keypad should be connected into the 13 terminal The BLACK wire of the wired keypad should be connected into the 1...

Страница 13: ...en 2 Potentiometers Potentiometer A and B are used to adjust the stall force and auto close time of the gate operator separately Turn potentiometer A clockwise to increase the stall force and turn it...

Страница 14: ...obstruction or resistance such as strong wind or heavy snow sometimes Note 2 Always check the gate reversing function every each time of control board set or restart after power off How to learn or e...

Страница 15: ...corrected Symptom Possible Solution s The remote control does not emit any single Check the batteries are exhausted replace them if necessary The operator doesn t run 1 Make sure that the power cord i...

Страница 16: ...www WholesaleGateOpener com 7106 S 220th St Kent WA 98032 USA sales WholesaleGateOpener com 2012 2014 ALEKO All Rights Reserved...

Отзывы: