12
DIP Switch #1–#2: Running time of the motor in Midway Mode
DIP Switch #1: ON
–2 Seconds
OFF
–0
DIP Switch #2: ON
–4 Seconds
OFF
–0
NOTE: The midway mode function would be disabled if both DIP switches are turned off. Factory
default setting is disabled.
DIP Switch #3: Auto close function enabled/disabled
DIP Switch #3: ON
–auto close function enabled
OFF
–auto close function disabled
DIP Switch #4: Left/Right open
2. Potentiometers
Potentiometer A and B are used to adjust the stall force and auto close time of the gate operator separately.
Turn
potentiometer A
clockwise to increase the stall force, and turn it counter-clockwise to decrease the
stall force.
Turn
potentiometer B
clockwise to increase the auto close time, and turn it counter-clockwise to decrease
the auto close time, the auto close time could be adjusted steplessly from 1 to 99 seconds.
E.g. Running time of the operator in pedestrian mode is 2 seconds.
E.g. Auto close function of the opener has been enabled. Factory default setting is disabled.