16  | Alderon Industries™ - Leading Edge Control Products

VertiMAC™ Pump Switch - USER GUIDE 

Discharge

VertiMAC™

Pump Switch

6.0” Pipe

Limited Space Dewatering

The diagram below is a typical setup for a dewatering application where a pump switch cannot operate due to limited space. 

The VertiMAC™ pump switch is mounted to the discharge pipe inside a six inch (6.0”) pipe placed in the ground. With the pump 

and discharge pipe inside the small size of the pipe, a typical pump switch would not have enough space to pivot and activate 

the pump. The VertiMAC™ pump switch and pump power cables are wired to terminal inputs in a junction box. The float is used 

to operate the pump switch, turning the pump on and off based on the pump differential for the desired pumping range.

Содержание VertiMAC VM13 Series

Страница 1: ...USER GUIDE MODEL NUMBER VM13 Series VertiMAC Pump Switch 13 Amp...

Страница 2: ...onnecting Power 10 Testing 10 Additional Assembly and Product Information 11 12 General Operation 13 Sump Pump 13 Sump Pump with VertiMAC Sump Advisor System 14 Sump Pump with Battery Backup 15 Limite...

Страница 3: ...ble local electrical and mechanical codes Refer to the National Electrical Code NFPA 70 Failure to properly install and test this product can result in personal injury or equipment malfunction 1 DISCO...

Страница 4: ...or piggyback plug 13 Amp models 5 Sump Advisor Sensor The Sump Advisor sensor attaches on top of the VertiMAC pump switch and connects to the Sump Advisor alarm panel The sump sensor integrates the h...

Страница 5: ...or lowers on the rod 4 Float Slides up and down the actuator rod to turn the pump on and off 5 Rubber Grommet Placed on the actuator rod at the determined location for desired pump differential 6 Pip...

Страница 6: ...tial Maximum Differential Move the rubber grommet to the bottom of the actuator rod to create the largest pump differential which is six inches 6 0 Minimum Differential Move the float and rubber gromm...

Страница 7: ...be released 1B using either a slotted screwdriver or 5 16 nut driver on the fastener nut 1A 1B STEP 2 INSTALL PIPE CLAMP Slide the pipe clamp through the loop on the pre installed pipe clamp bracket...

Страница 8: ...bles and wires away from the float while mounting Note Do not completely secure pipe clamp and VertiMAC pump switch to the pipe until the off level has been determined See step 4 final mounting locati...

Страница 9: ...ake sure level is above the intake to the pump to prevent dry cycling Refer to the instructions that came with the pump for complete operation information Once the pump switch is in the final mounting...

Страница 10: ...the actuator rod is in the up position activated the pump should be on STEP 3 PUMPING RANGE After testing is complete the pumping range can be adjusted by moving the rubber grommet up or down the actu...

Страница 11: ...switch housing and line up the holes Use a 2 phillips head screwdriver to securely fasten the bracket to the housing with provided screws INSERTING ACTUATOR ROD Slide the actuator rod arm upward into...

Страница 12: ...cure the float on the rod The pump differential can be adjusted by sliding the rubber grommet up and down the actuator rod See step 1 determining pump differential on page 6 PUMP SWITCH PUMP OFF and P...

Страница 13: ...l slide the rubber grommet up or down the actuator rod for the desired pumping range The applications are not limited to what is listed in this user guide Follow all individual instructions for sensor...

Страница 14: ...tion When the water level rises the float pushes the actuator rod upward which activates the mechanism inside the pump switch housing and turns the pump on The Sump Advisor sensor will send a signal t...

Страница 15: ...ump switch as a backup The cables for the backup pump switch and sensor are connected to the control panel for the battery backup system When the water level rises and activates the primary VertiMAC p...

Страница 16: ...ertiMAC pump switch is mounted to the discharge pipe inside a six inch 6 0 pipe placed in the ground With the pump and discharge pipe inside the small size of the pipe a typical pump switch would not...

Страница 17: ...ition while the pump continues to run Internal switch has failed The VertiMAC pump switch is at the end of its life cycle replace immediately Float in the up position but the pump does not turn on Pow...

Страница 18: ...ting Temperature Certifications 120VAC or 240VAC 60 Hz voltage depends on part number 13 Amps 120VAC 0 5HP or 240VAC 1 5HP SJT 16 gauge Bare Lead no plug 120 240VAC Piggyback Plug 120VAC or 240VAC vol...

Страница 19: ...r part Please contact the sales representative in your area to determine the designated Alderon location for return and to obtain the return goods authorization If you do not have a sales representati...

Страница 20: ...Hawley MN 56549 Main Office Phone 218 483 3034 Website alderonind com General Inquiry Email info alderonind com Submit New Orders orders alderonind com UG00012_Rev01_VertiMAC Pump Switch 13A July 5 20...

Отзывы: