10 | Alderon Industries™ - Leading Edge Control Products
VertiMAC™ Pump Switch - USER GUIDE
Connecting Power
PIGGYBACK PLUG MODELS
1) Plug the male end of the piggyback plug on the VertiMAC™
pump switch power cable into a standard wall outlet or power
receptacle that matches the voltage of the pump switch (A).
2) Plug the male end of the pump power cable into the female
end of the piggyback plug on the VertiMAC™ pump switch
power cable (B).
B
A
VertiMAC™ Pump Switch
Piggyback Plug
Power Cable
Pump
Power Cable
Testing
Activation Level
Deactivation Level
Pumping
Range
Make sure the installation process is completed and there is
power to the product.
STEP 1: TEST PUMP OFF
When the actuator rod is in the down position (deactivated), the
pump should be off.
STEP 2: TEST PUMP ON
When the actuator rod is in the up position (activated), the pump
should be on.
STEP 3: PUMPING RANGE
After testing is complete, the pumping range can be adjusted
by moving the rubber grommet up or down the actuator rod to
achieve the desired pump differential.
WARNING:
If making any adjustments to the VertiMAC™ pump switch after
testing has been completed, make sure to disconnect all power sources before
servicing the product.
BARE LEAD MODELS
1) Connect bare lead wires from the VertiMAC™ pump switch
power cable to terminal inputs in a junction box as shown in
the diagram.
WARNING:
In 240VAC installations, one side of the line going to the load is
always HOT. This condition exists if the switch is on or off. Install double pole
disconnect on all 240VAC circuits.
Make sure the installation process is completed and there are
no cables or wires to interfere with the operation of the float.
POWER SOURCE
G L2/N L1
WIRE USING
JUNCTION BOX
120/240 VAC
G
BLACK
WHITE
LOAD
G L2/N L1