VersAlarm™ I/O - USER GUIDE

Introduction

The VersAlarm™ I/O is a versatile option for indoor and outdoor utility monitoring. This alarm can be used for a wide variety 

of applications, including but not limited to: septic tanks, sump pits, holding tanks, pump chambers, and water tanks. The  

VersAlarm™ I/O has several setup options that include: indoor wall mount and outdoor mounting to a wall or post. Visit our 

website alderonind.com to view different options and accessories. In addition, there are a variety of sensors to use with the 

VersAlarm™ I/O for liquid level monitoring.

Safety Guidelines

Before proceeding with the installation or operation of this product, read all instructions thoroughly, as well as complying with 

all federal, state and local codes, regulations, and practices. This product must be installed by qualified personnel familiar with 

all applicable local electrical and mechanical codes. Refer to the National Electrical Code (NFPA 70). Failure to properly install 

and test this product can result in personal injury or equipment malfunction.

WARNING

1.  DISCONNECT POWER when installing or servicing the product. Failure to disconnect all power sources could result in  

 

serious injury or death.

2.  NEVER enter a flooded space without proper Personal Protective Equipment (PPE). Always wear dielectric rubber boots  

 

and other applicable protective equipment when water is on the floor and you must service an energized pump, alarm  

 

system, or product.

3.  DO NOT enter the water if the water level is higher than that of the protection your PPE offers or if your PPE is not 

 watertight.

4.  DO NOT use this product with or near flammable liquids.

5.  DO NOT install this product in locations classified as hazardous or in explosive atmospheres as defined by any applicable  

 

electrical safety code.

Содержание VersAlarm I/O

Страница 1: ...USER GUIDE MODEL NUMBER VLIO 00004 VersAlarm I O Indoor Outdoor Alarm Panel...

Страница 2: ...all Mounting Enclosure 6 7 Wiring 7 8 Testing the Alarm 9 General Operation 10 Sump Pit Monitoring 10 Septic Tank Monitoring 11 Flood Monitoring 12 Alarm Auxiliary with Auto Dialer 13 Troubleshooting...

Страница 3: ...practices This product must be installed by qualified personnel familiar with all applicable local electrical and mechanical codes Refer to the National Electrical Code NFPA 70 Failure to properly ins...

Страница 4: ...1 2 3 Alarm Float Switch The alarm float switch is the default sensor option for liquid level monitoring 4 VertiMAC The VertiMAC switch is a sensor for liquid level monitoring that is similar to that...

Страница 5: ...an alarm condition it will silence the buzzer and the red LEDs will stop flashing and remain solid 5 Auxiliary Contacts One set of auxiliary contact terminals are included allowing the alarm to interf...

Страница 6: ...until sound chamber is cleared 1A and pull directly away from the enclosure 1B STEP 2 INSTALLING CONDUIT FITTINGS Using the premarked center hole locations 2A mark and drill out on the bottom of the...

Страница 7: ...minals on the terminal block that consists of three pairs of connections 1 Starting from the right the first pair of terminals 5 and 6 are for the power mains The first line connection L1 is installed...

Страница 8: ...ning up with the grooves 3A Then slide the bottom piece upward 3B until it meets the top piece and screw hole is lined up with the boss Replace the screw at the bottom of the enclosure STEP 2 INSTALLI...

Страница 9: ...iate STEP 2 TEST SENSOR The sensor should be connected to terminals 3 and 4 Activate the sensor the red LEDs should illuminate flashing and the buzzer should annunciate STEP 3 TEST ALARM SILENCE Press...

Страница 10: ...iary with Auto Dialer The diagram below is a typical setup for sump pit monitoring The VersAlarm I O is mounted on the wall The pump and alarm are powered by 230VAC The WaterSpotter probe sensor is co...

Страница 11: ...ilence pushbutton is pressed during an alarm condition then the top cover of the enclosure will turn solid red and the buzzer will silence The silence condition will reset when the alarm float switch...

Страница 12: ...are attached to household utilities Examples washing machine water heater water softener sink or any other area that has potential for flooding If no water is detected in the monitoring area then the...

Страница 13: ...hen the top cover of the enclosure will be green If the probes are partially or fully submerged then the top cover of the enclosure will flash red the buzzer will annunciate and auxiliary contacts clo...

Страница 14: ...ung up on something Make sure the float switch is free and the line is tethered at desired location in a secure fashion If the float switch is old the contacts could be stuck shut Replace the float sw...

Страница 15: ...uency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in...

Страница 16: ...rt Please contact the sales representative in your area to determine the designated Alderon location for return and to obtain the return goods authorization If you do not have a sales representative i...

Страница 17: ...Alderon Industries Leading Edge Control Products 17 VersAlarm I O USER GUIDE This page intentionally left blank...

Страница 18: ...18 Alderon Industries Leading Edge Control Products VersAlarm I O USER GUIDE This page intentionally left blank...

Страница 19: ...Alderon Industries Leading Edge Control Products 19 VersAlarm I O USER GUIDE This page intentionally left blank...

Страница 20: ...awley MN 56549 Main Office Phone 218 483 3034 Website alderonind com General Inquiry Email info alderonind com Submit New Orders orders alderonind com UG00004_Rev03_VLIO 00004_VersAlarm IO August 26 2...

Отзывы: