VersAlarm™ I/O - USER GUIDE

Septic Tank Monitoring

The diagram below shows the typical setup for septic tank monitoring. The VersAlarm™ I/O is shown in two locations to demon-

strate the most typical options for septic tank monitoring. The alarm float switch is connected to the sensor input for high water 

indication. If water level is not high enough to activate the alarm float switch, then the top cover of the enclosure will be green. 

If the alarm float switch is activated, then the top cover of the enclosure will flash red and the buzzer will annunciate. The alarm 

condition will stay on until the alarm float switch is deactivated. If the silence pushbutton is pressed during an alarm condition, 

then the top cover of the enclosure will turn solid red and the buzzer will silence. The silence condition will reset when the alarm 

float switch deactivates. If the alarm is in silence mode for longer than 24 hours, the alarm will reactivate.

1)  Indoor Application - The first option shows the VersAlarm™ I/O mounted in the utility room. The alarm float switch will   

  need splicing for the additional wire length. A second common indoor installation method is mounting the alarm in the   

  garage (not shown).

2)  Outdoor Application - The second option is to mount the VersAlarm™ I/O to a post in the ground next to the septic tank.  

  This option would require a shorter alarm float switch cable length and running the power mains out to the alarm.

13:27

Cycle: WASH

HEAT

TIME

START

Septic

to 

Drain Field

VersAlarm™ I/O

VersAlarm™ I/O

Alarm

Float

Pump

Switch

2

1

Содержание VersAlarm I/O

Страница 1: ...USER GUIDE MODEL NUMBER VLIO 00004 VersAlarm I O Indoor Outdoor Alarm Panel...

Страница 2: ...all Mounting Enclosure 6 7 Wiring 7 8 Testing the Alarm 9 General Operation 10 Sump Pit Monitoring 10 Septic Tank Monitoring 11 Flood Monitoring 12 Alarm Auxiliary with Auto Dialer 13 Troubleshooting...

Страница 3: ...practices This product must be installed by qualified personnel familiar with all applicable local electrical and mechanical codes Refer to the National Electrical Code NFPA 70 Failure to properly ins...

Страница 4: ...1 2 3 Alarm Float Switch The alarm float switch is the default sensor option for liquid level monitoring 4 VertiMAC The VertiMAC switch is a sensor for liquid level monitoring that is similar to that...

Страница 5: ...an alarm condition it will silence the buzzer and the red LEDs will stop flashing and remain solid 5 Auxiliary Contacts One set of auxiliary contact terminals are included allowing the alarm to interf...

Страница 6: ...until sound chamber is cleared 1A and pull directly away from the enclosure 1B STEP 2 INSTALLING CONDUIT FITTINGS Using the premarked center hole locations 2A mark and drill out on the bottom of the...

Страница 7: ...minals on the terminal block that consists of three pairs of connections 1 Starting from the right the first pair of terminals 5 and 6 are for the power mains The first line connection L1 is installed...

Страница 8: ...ning up with the grooves 3A Then slide the bottom piece upward 3B until it meets the top piece and screw hole is lined up with the boss Replace the screw at the bottom of the enclosure STEP 2 INSTALLI...

Страница 9: ...iate STEP 2 TEST SENSOR The sensor should be connected to terminals 3 and 4 Activate the sensor the red LEDs should illuminate flashing and the buzzer should annunciate STEP 3 TEST ALARM SILENCE Press...

Страница 10: ...iary with Auto Dialer The diagram below is a typical setup for sump pit monitoring The VersAlarm I O is mounted on the wall The pump and alarm are powered by 230VAC The WaterSpotter probe sensor is co...

Страница 11: ...ilence pushbutton is pressed during an alarm condition then the top cover of the enclosure will turn solid red and the buzzer will silence The silence condition will reset when the alarm float switch...

Страница 12: ...are attached to household utilities Examples washing machine water heater water softener sink or any other area that has potential for flooding If no water is detected in the monitoring area then the...

Страница 13: ...hen the top cover of the enclosure will be green If the probes are partially or fully submerged then the top cover of the enclosure will flash red the buzzer will annunciate and auxiliary contacts clo...

Страница 14: ...ung up on something Make sure the float switch is free and the line is tethered at desired location in a secure fashion If the float switch is old the contacts could be stuck shut Replace the float sw...

Страница 15: ...uency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in...

Страница 16: ...rt Please contact the sales representative in your area to determine the designated Alderon location for return and to obtain the return goods authorization If you do not have a sales representative i...

Страница 17: ...Alderon Industries Leading Edge Control Products 17 VersAlarm I O USER GUIDE This page intentionally left blank...

Страница 18: ...18 Alderon Industries Leading Edge Control Products VersAlarm I O USER GUIDE This page intentionally left blank...

Страница 19: ...Alderon Industries Leading Edge Control Products 19 VersAlarm I O USER GUIDE This page intentionally left blank...

Страница 20: ...awley MN 56549 Main Office Phone 218 483 3034 Website alderonind com General Inquiry Email info alderonind com Submit New Orders orders alderonind com UG00004_Rev03_VLIO 00004_VersAlarm IO August 26 2...

Отзывы: