ALCO EC3-33x Скачать руководство пользователя страница 16

EC3-33x Coldroom Controller with EX5

User Manual

EC3-33x

A.6.5.063E - Rev 4

16

Emerson Electric GmbH & Co  -  ALCO CONTROLS  -  Heerstr. 111  -  D-71332 Waiblingen  -  Germany - Tel.: ..49 (0) 7151 509 0 - Fax: 49 (0) 7151 509 200

Configuration Parameters

De fro st

U NV T_ DE FR O ST

Code

De s

cr i pti on

Vari able t ype

Nam e

U nit

M in

M ax

D efau lt

Res.

IR

Kb

Lon

0

d0

Defr ost  m ode

unsi gned shor t Mode

0

2

1

y

y

y

* 1

1

d1

Term inat ion t im e 

/  t emp

unsi gned shor t Term inat ion

0

3

0

y

y

y

* 2

2

d2

Defr ost  t erm inat ion sensor

unsi gned 

shor t Sensor

0

1

1

y

y

y

* 3

3

d3

Pulsed def rost

unsi gned shor t Pul sedDefr

0

1

0

y

y

y

* 4

.

.

.

.

.

4

d4

Defr ost  at  pow er up

unsi gned 

shor t Power UpD efr

0

1

0

y

y

y

* 5

5

d5

Tim e del ay f or power  

up defr ost unsi gned shor t Fir st Defr Del ay

mi n

0

180

0

y

y

y

D elay ti me for  defr ost at power  

up

6

d6

Pum p dow n del ay

unsi gned shor t Pum pDwnD elay

sec

0

180

0

y

y

y

P ump down durat ion befor e defr ost  rel ay ar e acti v

at ed

7

d7

Dr ain down delay

unsi gned 

shor t Dr ainDel ay

mi n

0

15

2

y

y

y

D urat ion of dr aining 

8

d8

Inj ecti on del ay

unsi gned shor t Inj Delay

sec

0

180

0

y

y

y

Ti me  bef ore rest art ing r efr iger ati on

9

d9

Dem and def rost  m ode

unsi gned shor t Dem andDefr

0

2

2

y

y

y

* 6

10

dd

Defr ost  pul sed di ff erence

unsi gned shor t Pul sedDif f

K

1

20

2

 y

y

y

D efr ost heat er cut  in  dif fer ence

11

dH

Defr ost  pul sed st op t em perat ure si gned shor t

Pul sedCutout

° C

- 40

dt

5

 y

y

y

D efr ost heat er  ter mi nati on  tem perat ure

12

dt

Defr ost  st op t em perat ure

si gned shor t

Term Tem p

° C

- 40

90

8

y

y

y

D efr ost  t erm inat ion tem per atur e

13

dP

Max defr ost  t im e

unsi gned shor t Term Tim e

mi n

1

180

30

y

y

y

M axi mum  def rost  dur at ion

14

dI

Defr ost  t im e i nter val

unsi gned shor t Int erval Tim e

h

0

192

8

y

y

y

Ti me  i nter v

al  bet ween tw o def rost  cycles

15

dU

St art  up delay

unsi gned 

shor t St art UpDl y

mi n

1

180

30

y

y

y

D elay  ti me  t o t erm inat e a  synchr onised  defr ost if  

ext er nal  sig

16

 Sensor  

sel ecti on

unsi gned shor t EI Sensor

0

31

0

n

n

y

* 7

Tot al  17 bytes

* 1

0 =  nat ural , Heat er out put not acti vated,  pul sed def rost  not possibl e

1 =  f orced defr ost,  Synchroni sati on by 

bi ndings,  Heat er  out put act ivated,  pul sed defr ost possibl e

2 =  f orced defr ost,  Synchroni sati on wit h 

ext er nal star t up signal,  Heater  output  act ivat ed, pulsed defr ost  possi ble

* 2

0 =  t emper at ure,  t im e w il l generat e an er ror
1 =  t im e,  tem per atur e w il l generat e an er ror

2 =  f ir st,  w hat ever comes fi rst , no err or gener ati on
3 =  l ast,  w hat ever comes last , no err or gener ati on

* 3

0 =  nviTem per atur e1 or  f in sensor

1 =  nviTem per atur e2 or  ai r  out  sensor

* 4

0 =  of f,  no pulsed defr ost,  heater s sw it ched of f at defr ost  t erm inat ion tem per atur e dt  or  ti me what ever is select ed

1 =  on,  pul sed def rost ,  dd and 

dH  i n use,  heat er s ar e sw it ched of f at dH and 

sw it ched on again at  

dH -  

dd 

* 5

0 =  no
1 =  yes

* 6

0 =  of f

1 =  dem and
2 =  dem and +  t im e dI

* 7

Val ue = Tem perat ure 1 

+  Tem perat ur e 2 + 

A ir  i n t emp.  + 

C oil  i n t emp

Temper at ure 1,    0 = local , 1 

=  LO N networ k

Temper at ure 2, 0 = 

l ocal,  2 = LON net work

Ai r in tem p.,             0 

= local , 8 = 

LO N netw ork

Coi l in tem p.,          0 = local , 16 

= LO N 

net wor k

Alarm Messages

Alarm messages will be send by the “nvoAlarm” of  the node object.

Condition

SNVT #

Alarm Value

Message

Priority

Defrost termination alarm occurs

83

IntAlarm

AL_ALM_CONDITION

PR_LEVEL_0

Defrost termination alarm disappears

83

IntAlarm

AL_NO_CONDITION

PR_LEVEL_0

SNVT_state        IntAlarm;      // Internal alarm status
                                               // Bit0  1 = Termination by time
                                               // Bit1  1 = Termination by temperature
                                               // Bit2  1 = Synchronized defrost terminated by time

Содержание EC3-33x

Страница 1: ...EC3 33x User Manual Rev 4 14 01 2003...

Страница 2: ...ill return to the by 1 selected data NEURON ID SERVICE BUTTON Display Press the button for app 1 second to send the Neuron ID An LED in the left upper corner will indicate the transmission of the Neur...

Страница 3: ...1 flag 1 d3 Pulsed defrost 0 1 flag 0 d4 Defrost at power up 0 1 flag 0 d5 Delay for power up defrost 0 180 min 0 d6 Pump down delay 0 180 sec 0 d7 Drain delay 0 180 min 2 d8 Injection delay 0 180 se...

Страница 4: ...in and air out sensor monitoring off temp alarms will be generated A0 Mean factor alarm temperature r8 Mean factor day operation r9 Mean factor night operation Temperature calculation by the followin...

Страница 5: ...eaning 0 off 1 on u0 Refrigerant 0 R22 1 R134a 2 R507 3 R404A 4 R407C u1 Correction Glide positive Values Pressure drop negative Values u2 MOP Control 0 off 1 on u4 Control Mode 0 off 1 fixed superhea...

Страница 6: ...n failure by time or temperature Ft Fan start up failure by time or temperature Ab external battery alarm external battery indicates an alarm MESSAGES No data The display will show an at node start up...

Страница 7: ...ressor failure Door contact Switch 1 Switch 2 oil in oil out Air in temp Air out temp Defrost termination temp Temp 6 Switch 24V AC DC or 230V AC Sensor NTC 10K at 25 C Pressure Sensor PT3 07 4 20 mA...

Страница 8: ...BL BK WH Battery Fail 24V AC Fan DI 1 8 24V AC DC or 230V AC DI 9 12 24V AC DC only DO 250V max 8A 2A Comp Heater Alarm Relay Door Comp safety Di3 Di4 Do1 1 C 2 Do2 1 C 2 Do3 1 C 2 Do4 1 C 2 LON A B...

Страница 9: ...sensors is between 9 and 3 o clock as shown on the picture The air sensors must be mounted on spacers in the middle of the air duct so that the air flow around The recommended positions in detail 1 S1...

Страница 10: ...nding on cable type Transfer rate 39 kbits s FTT10 Structure free topology Termination RC Network Medium Twisted pair 2 wires Connection 11 12 Data 13 free Nodes Segment 64 Units Cable length max 2700...

Страница 11: ...0 7151 509 0 Fax 49 0 7151 509 200 NODE OBJECTS The EC3 33x coldroom controller has 11 LonMark Objects EC3 33x Node Object Compressor Object 20004 Display Object 20006 Analog Sensor Object 20008 Evapo...

Страница 12: ...all objects in the node to normal operation RQ_DISABLED This requested object is disabled output network variable of the object will not longer be updated The object will not reacted on input network...

Страница 13: ...ostat object SNVT_temp_p nvoAlarmAirTemp O Alarm temperature used by thermostat object SNVT_temp_p nvoAirOutTemp O Air out sensor temperature SNVT_temp_p nvoAirInTemp O Air in sensor temperature SNVT_...

Страница 14: ...on unsigned short MeanNight 0 100 50 y y y 5 17 rd Difference day operation unsigned short DiffDay K 0 1 20 2 0 1 y y y Diff between cut in cut out 18 St Setpoint day operation signed long SpDay C r1...

Страница 15: ...oDefrTemp O Currently used defrost termination temperature SNVT_lev_disc nvoHeater O Status of the defrost heater SNVT_lev_disc nviStartUp I Input to terminate a synchronized defrost ST_ON will start...

Страница 16: ...14 dI Def r ost t i m ei nt er val unsi gnedshor t I nt er val Ti m e h 0 192 8 y y y Ti m e i nt er v al bet ween t w odef r ost cycl es 15 dU St ar t up del ay unsi gnedshor t St ar t UpDl y m i n...

Страница 17: ...l control 8 1 Termination error Configuration Parameters Fan UNVT_FAN Code Description Variable type Name Unit Min Max Default Res IR Kb Lon 0 F1 Fan startup sequence after defrost unsigned short Star...

Страница 18: ...ct SNVT_lev_disc nviCompSafety Failure input for compressor safety ST_ON compressor off and locked UNVT_COMP nciCompCnfg C Configuration parameters of the fan object The network variable nvoCompStatus...

Страница 19: ...pad unsigned short IrKb 0 3 3 y y y 1 1 H3 IR access code unsigned short IRCode 0 199 0 y y y 2 H5 Password unsigned short PassWord 0 199 12 y y y 3 1 Value to be shown unsigned short Data 0 11 0 y y...

Страница 20: ...ircuit E2 6 Air out sensor open E3 7 Air out sensor short circuit E3 8 Defrost termination sensor open E4 9 Defrost termination sensor short circuit E4 10 Temperature 6 sensor open E5 11 Temperature 6...

Страница 21: ...perheat object SNVT_temp_p nvoEvapOutTemp O Currently used coil out temperature of the superheat object SNVT_switch nviForcedValve I Manual control of the valve output SNVT_temp_p nvoSuperheatRef O Cu...

Страница 22: ...n n y 5 9 uu Start up opening unsigned short Opening 50 100 100 y y y 10 ut Valve type unsigned short ValveType 0 3 0 y y y 7 11 Data source unsigned short Sensor 0 31 0 n n y 6 Total 13 bytes 1 0 R2...

Страница 23: ...trols the relays and the TRIAC If the object is disabled the object will not react on any network variable update and the digital outputs will stay unchanged Network Variables Variable Type Name Type...