OmniSwitch 6900 Chassis
Chassis and Power Supplies
page 3-10
OmniSwitch 6900 Hardware Users Guide
June 2020
OS6900-T20 and OS6900-T40 Chassis Specifications
Note.
For OS6900-X20 and OS6900-X40 chassis specifications, please refer to page
. For
OS6900-Q32 chassis specification, please refer to page
.
1
Fully populated weights include fan tray, all installable power supplies and expansion modules. These
figures do not include transceivers
.
2
Fully populated front panel (no expansion modules).
See individual expansion modules for power
consumption information.
Chassis Width (without brackets)
43.3 cm (17.06 inches)
Chassis Height
4.4 cm (1.73 inches or 1RU)
Overall Chassis Depth
55.9 cm (22 inches)
OS6900-T20 Chassis Weight
7.61 kg (16.8 lb)
OS6900-T20 Chassis Weight (fully populated)
1
10.21 kg (22.5 lb)
OS6900-T40 Chassis Weight
7.78 kg (17.15 lbs)
OS6900-T40 Chassis Weight (fully populated)
1
10.86 kg (23.95 lbs)
Power Supply Bays
2
OS6900-T20 Power Consumption
2
206 Watts
OS6900-T40 Power Consumption
2
329 Watts
Operating Temperature (Tmra)
OS6900-T20-F (front-to-rear airflow)
OS6900-T20-R (rear-to-front airflow)
OS6900-T40-F (front-to-rear airflow)
OS6900-T40-R (rear-to-front airflow)
0°C to 45°C (32°F to 113°F)
0°C to 45°C (32°F to 113°F)
0°C to 40°C (32°F to 104°F)
0°C to 45°C (32°F to 113°F)
Storage Temperature
-10°C to +70°C (14°F to 158°F)
OS6900-T20 Temp Warning Threshold (front-to-rear airflow)
67°C (152°F) chassis temp*
OS6900-T20 Temp Warning Threshold (rear-to-front airflow)
61°C (141°F) chassis temp*
OS6900-T40 Temp Warning Threshold (front-to-rear airflow)
77°C (170°F) chassis temp*
OS6900-T40 Temp Warning Threshold (rear-to-front airflow)
62°C (143°F) chassis temp*
OS6900-T20 Temp Danger Threshold (front-to-rear airflow)
77°C (170°F) chassis temp*
OS6900-T20 Temp Danger Threshold (rear-to-front airflow)
71°C (159°F) chassis temp*
OS6900-T40 Temp Danger Threshold (front-to-rear airflow)
89°C (192°F) chassis temp*
OS6900-T40 Temp Danger Threshold (rear-to-front airflow)
76°C (168°F) chassis temp*
Operating Humidity
5% to 95% non-condensing
Storage Humidity
5% to 95% non-condensing
Cable Supported
Cat 5e; Cat 6; Cat 6a; Cat 7
Cable Distances
55 meters Cat 5e and Cat 6
100 meters Cat 6a and Cat 7