OmniSwitch 6350 Chassis and Hardware Components
Overtemp Condition
OmniSwitch 6350 Hardware Users Guide
April 2017
page 3-25
10/100/1000 Mbps Power over Ethernet Port – RJ-45 Pinout
Overtemp Condition
The OmniSwitch is designed to operate within a specified operating temperature as noted under the
specifications section. However, in the event that the normal operating temperature of the switch is
exceeded, the following will occur:
•
Upon crossing the configured Upper Threshold, a trap will be sent. (See the
OmniSwitch AOS Release
6 Network Configuration Guide
for information on configuring switch thresholds.)
If the temperature continues to rise and reaches the Danger Threshold, the following will occur:
•
OK1 LED will display solid Amber.
•
The switch will automatically shutdown
•
Once the temperature drops to an acceptable operating level, the switch will automatically restart.
Check the following if an overtemp condition exists:
•
Verify that the switch is installed properly in an environment that adheres to the installation
instructions in the following chapters.
•
Verify proper airflow to the chassis.
•
Time of the failure
Use the
command and refer to the SNMP Configuration chapter for information on
configuring an SNMP station.
Pin Number
Description
1
RX+ (-VDC)
2
RX- (-VDC)
3
TX+ (+VDC)
4
5
6
TX- (+VDC)
7
8