Synchronizing Switches in a Stack
Managing OmniSwitch 6350 Stacks
page 7-36
OmniSwitch 6350 Hardware Users Guide
April 2017
Synchronizing Switches in a Stack
Management module synchronization refers to the process of copying all files in the
/flash/working
and
/flash/certified
directories of the primary management module to the
/flash/working
and
/flash/certified
directories of all the other switches in the stack. The system and configuration software on the non-
primary switches—i.e., the secondary management module and any modules operating in idle—is
overwritten.
The synchronization process ensures that the contents of these directories match exactly for all switches
across the stack. This can be especially useful after new software has been loaded to the primary
management module. Further, synchronization prevents any switch from assuming a management role
within the stack with incorrect or outdated software or configuration files. Because the primary switch’s
“last known good” software is propagated to all switches, the synchronization process helps ensure
effective redundancy across the stack.
In order to maintain effective management module redundancy, switches in the stack must be
synchronized at all times. To determine whether a stack is in need of synchronization, use the
command. For example:
-> show running-configuration
CONFIGURATION STATUS
Running CMM : PRIMARY,
CMM Mode : MONO CMM,
Current CMM Slot : 1,
Running configuration : CERTIFIED,
Certify/Restore Status : CERTIFY NEEDED
SYNCHRONIZATION STATUS
Running Configuration : NOT SYNCHRONIZED,
This example shows a switch on which the /flash directories between the management modules are not
synchronized. To manually synchronize all switches in the stack, enter the following command:
-> copy working certified flash-syncro
When the synchronization process is initiated, modules within the stack continue to operate without
interruption and data flow across the stack is unaffected.
Automatic Synchronization During a Full Reload
If the checksum value on the stack’s non-primary switches differs in any way from the checksum value on
the primary switch, the primary switch automatically distributes its system and configuration software to
all other switches in the stack whenever a full reload is executed.
For more information on initiating a full reload, see
“Reloading All Switches in a Stack” on page 7-31
Note.
For more information on management module synchronization and managing the
/flash/working
and
/flash/certified
directories, refer to the “Managing CMM Directory Content” chapter in the
OmniSwitch AOS Release 6
Switch Management Guide
.