background image

Standards Compliance

Regulatory Compliance and Safety Information

page A-4

OmniSwitch 6350 Hardware Users Guide

April 2017

Standards Compliance

Safety Standards

UL 60950-1, 2nd Edition

CAN/CSA-C22.2 No. 60950-1-07, 2nd Edition

EN 60950-1 with Amendment II

IEC 60950-1 2nd Edition

AS/NZS TS-001 and 60950, Australia

UL-AR, Argentina

TUV,UL-GS Mark, Germany

NOM-019 SCFI, Mexico

EN 60825-1 Laser

EN 60825-2 Laser

CDRH Laser

CB Certification per IEC 60950-1, Second Edition

EMC Standards

FCC Part 15 (CFR 47) Class A

ICES-003 Class A

EN 55022 Class A

CISPR 22 Class A

AS/NZS 3548 Class A

VCCI Class A; A1 and A2

EN 55024 (Immunity)

EN 61000-3-2

EN 61000-3-3

EN 61000-4-2

EN 61000-4-3

EN 61000-4-4

EN 61000-4-5

EN 61000-4-6

EN 61000-4-8

EN 61000-4-11

Environmental Standards

ETS 300 019 Storage Class 1.1

ETS 300 019 Transportation Class 2.3

ETS 300 019 Stationary Use Class 3.1

Содержание OmniSwitch 6350

Страница 1: ...Part No 060406 10 Rev E April 2017 OmniSwitch 6350 Hardware Users Guide enterprise alcatel lucent com...

Страница 2: ...e alcatel lucent com trademarks All other trademarks are the property of their respective owners The information presented is subject to change without notice Neither ALE Holding nor any of its affili...

Страница 3: ...niSwitch 6350 Switches 1 1 Chassis Configurations 1 1 10 Port Models 1 1 24 Port Models 1 1 48 Port Models 1 1 OmniSwitch 6350 Feature Overview 1 2 Security Features 1 2 Availability Features 1 2 Soft...

Страница 4: ...assis Features 2 2 Front Panel 2 2 OmniSwitch 6350 10 Rear Panel 2 3 OmniSwitch 6350 P10 2 5 Chassis Features 2 5 Front Panel 2 5 OmniSwitch 6350 P10 Rear Panel 2 6 OmniSwitch 6350 24 2 8 Chassis Feat...

Страница 5: ...the Rack 3 7 Connecting the Chassis to a Power Source 3 8 AC Power Supply Connections 3 8 Powering On a Chassis 3 8 Chapter 5 Booting OmniSwitch 6350 Switches 4 1 Booting an OmniSwitch 4 1 Component...

Страница 6: ...Primary and Secondary Management Modules 6 3 Primary Management Module Selection 6 6 Secondary Management Module Selection 6 9 Idle Module Role 6 11 Pass Through Mode 6 12 Recovering from Pass Through...

Страница 7: ...2 Class A Warning A 5 Korea Emissions Statement A 6 A 6 VCCI A 6 Class A Warning for Taiwan and Other Chinese Markets A 6 Network Cable Installation Warning A 7 Translated Safety Warnings A 7 Chassis...

Страница 8: ...ts viii OmniSwitch 6350 Hardware Users Guide April 2017 Leer informaci n importante de seguridad A 13 Advertencia de acceso restringido A 13 Advertencia de pulsera antiest tica A 13 Clase de seguridad...

Страница 9: ...de This OmniSwitch 6350 Hardware Users Guide describes your switch hardware components and basic switch hardware procedures Supported Platforms The information in this guide applies to the following p...

Страница 10: ...witch configurations Descriptions of availability features Descriptions of chassis types Instructions for mounting the chassis Descriptions of hardware components status LEDs chassis cables etc Managi...

Страница 11: ...amental aspects of the switch such as hardware LEDs the software directory structure CLI conventions and web based management At this time you should also familiarize yourself with the Release Notes t...

Страница 12: ...g Tree The Network Configuration Guide contains overview information procedures and examples on how standard network ing technologies are configured in the OmniSwitch Anytime TheCLI Reference Guide co...

Страница 13: ...ns authenticated switch access managing switch files system configuration using SNMP and using web management software WebView OmniSwitch AOS Release 6 Network Configuration Guide Includes network con...

Страница 14: ...ement through our global network of highly qualified service delivery partners Additionally with 24 hour a day access to Alcatel Lucent s Service and Support web page you ll be able to view and update...

Страница 15: ...es eight 8 10 100 1000 BaseT PoE ports two 2 RJ 45 SFP combo ports The chassis features fanless design and internal AC power 24 Port Models OmniSwitch 6350 24 Provides 24 10 100 1000 BaseT ports and f...

Страница 16: ...Hardware Monitoring Software Rollback Software rollback also referred to as image rollback essentially allows the switch to return to a prior last known good version of software in the event of a sys...

Страница 17: ...niSwitch 6350 Chassis and Hardware Components User Driven Monitoring User driven hardware monitoring refers to CLI commands that are entered by the user in order to access the current status of hardwa...

Страница 18: ...OmniSwitch 6350 Feature Overview OmniSwitch 6350 Switches page 1 4 OmniSwitch 6350 Hardware Users Guide April 2017...

Страница 19: ...13 Fahrenheit and not exceed 95 percent maximum humidity non condensing at any time Be sure to allow adequate room for proper air ventilation at the front back and sides of the switch Refer to Airflow...

Страница 20: ...ollowing recommendations and guidelines 1 Earth grounding of all devices is fundamental to ensure long term reliability All electrical equipment must be installed by a qualified licensed electrician E...

Страница 21: ...hes Caution Category 5e Category 6 and Category 6a cables can store large amounts of static electricity due to the dielectric properties of their construction materials in addition this build up of el...

Страница 22: ...eginning Unpack your OmniSwitch 6350 chassis as close as possible to the location where it will be installed Items Included Your OmniSwitch 6350 includes the following items OmniSwitch chassis Transce...

Страница 23: ...arance at the front back and sides of the switch Never obstruct chassis air vents Chassis Top View Note Clearance is not required at the top and bottom of the chassis Mounting the Switch For informati...

Страница 24: ...or SFP ports Note For additional information on cabling connections refer to the OmniSwitch AOS Release 6 Switch Management Guide Serial Connection to the Console Port The console port provides a seri...

Страница 25: ...e is automatically resolved Component LEDs During the boot process component LEDs will flash and change color indicating different stages of the boot Following a successful boot chassis LEDs should di...

Страница 26: ...password Use the switch s default settings Login admin Password switch The default welcome banner which includes information such as the current software version and system date is displayed followed...

Страница 27: ...or more information on switch security refer to the Switch Management Guide Unlocking All Session Types To unlock all session types enter the following command syntax at the CLI prompt aaa authenticat...

Страница 28: ...he password information Also note that new password information is retained following a reboot All subsequent login sessions including those through the console port will require the new password to a...

Страница 29: ...a system name use the system name command Specifying the Switch s Location It is recommended that you use a physical labeling system for locating and identifying your switch es Examples include placi...

Страница 30: ...Your First Login Session Getting Started page 2 12 OmniSwitch 6350 Hardware Users Guide April 2017...

Страница 31: ...d pinout specifications OS6350 10 Eight 8 10 100 1000 BaseT ports two 2 RJ 45 SFP combo ports fanless design internal AC power OS6350 P10 Eight 8 10 100 1000 BaseT PoE ports two 2 RJ 45 SFP combo port...

Страница 32: ...to OmniSwitch 6350 LED Status on page 3 21 for LED status information System status LEDs Internal AC Power Supply 8 10 100 1000Base T Ports Console port RJ 45 2 RJ 45 SFP 10 100 1000 combo ports USB p...

Страница 33: ...ernal AC power supply B Grounding Block Type LCD8 10A L grounding lug OmniSwitch 6350 10 Specifications Fans None Power Supplies One 1 internal power supply Rack Unit Dimensions 1 RU Dimensions WxHxD...

Страница 34: ...witch 6350 Chassis and Hardware Components page 3 4 OmniSwitch 6350 Hardware Users Guide April 2017 Input Voltage 100 VAC to 240 VAC 0 9 A 50 60 Hz Output Voltage 12 VDC 2 5 A Max Power 30 W OmniSwitc...

Страница 35: ...itch 6350 LED Status on page 3 21 for LED status information System status LEDs Internal AC Power Supply 8 10 100 1000Base T PoE ports Console port RJ 45 2 RJ 45 SFP 10 100 1000 combo ports USB port U...

Страница 36: ...rnal AC power supply B Grounding Block Type LCD8 10A L grounding lug OmniSwitch 6350 P10 Specifications Fans None Power Supplies One 1 internal power supply Rack Unit Dimensions 1 RU Dimensions WxHxD...

Страница 37: ...nts OmniSwitch 6350 P10 OmniSwitch 6350 Hardware Users Guide April 2017 page 3 7 Input Voltage 100 VAC to 240 VAC 2 2 A 50 60 Hz Output Voltage 54 5 VDC 2 5 A Max Power 150 W 30 W System Power 120 W P...

Страница 38: ...el Refer to OmniSwitch 6350 LED Status on page 3 21 for LED status information System status LEDs Internal AC Power Supply 24 10 100 1000Base T Ports Console port RJ 45 4 Non combo SFP Ports USB port...

Страница 39: ...duct safety and compliance information labels All production versions of the chassis have these labels OmniSwitch 6350 24 Rear Panel OmniSwitch 6350 24 Internal AC Power Supply Item Description A Grou...

Страница 40: ...ations 10 100 1000BaseT ports 24 SFP ports 4 Chassis Width 44 0 cm 17 32 in Chassis Height 4 4 cm 1 73 in 1 RU Chassis Depth 25 2 cm 9 92 in Weight 4 08 kg 9 0 lb Operating Humidity 5 to 95 Storage Hu...

Страница 41: ...efer to OmniSwitch 6350 LED Status on page 3 21 for LED status information System status LEDs Internal AC Power Supply 24 10 100 1000Base T PoE ports Console port RJ 45 4 Non combo SFP Ports USB port...

Страница 42: ...compliance information labels All production versions of the chassis have these labels OmniSwitch 6350 P24 Rear Panel OmniSwitch 6350 P24 Internal AC Power Supply Item Description A Grounding Block Ty...

Страница 43: ...over Ethernet PoE Ports 24 SFP ports 4 Chassis Width 44 0 cm 17 32 in Total Power Budget 525 W System Power Budget 145 W PoE Power Budget 380 W Chassis Height 4 4 cm 1 73 in 1 RU Chassis Depth 25 2 c...

Страница 44: ...status LEDs Internal AC Power Supply 48 10 100 1000Base T Ports Console port RJ 45 4 Non combo SFP Ports USB port USB 2 0 Item Description A 48 10 100 1000 BaseT Ports B Ethernet Port Status LEDs C C...

Страница 45: ...duct safety and compliance information labels All production versions of the chassis have these labels OmniSwitch 6350 48 Rear Panel OmniSwitch 6350 48 Internal AC Power Supply Item Description A Grou...

Страница 46: ...ifications 10 100 1000BaseT ports 48 SFP ports 4 Chassis Width 44 0 cm 17 32 in Chassis Height 4 4 cm 1 73 in 1 RU Chassis Depth 25 2 cm 9 92 in Weight 5 44 kg 12 0 lb Operating Humidity 5 to 95 Stora...

Страница 47: ...LEDs Internal AC Power Supply 48 10 100 1000Base T PoE Ports Console port RJ 45 4 Non combo SFP Ports USB port USB 2 0 Item Description A 48 10 100 1000 BaseT Power over Ethernet PoE Ports B Ethernet...

Страница 48: ...P48 Rear Panel Note The figure shows a pre production version of the chassis without product safety and compliance information labels All production versions of the chassis have these labels OmniSwit...

Страница 49: ...OmniSwitch 6350 Hardware Users Guide April 2017 page 3 19 OmniSwitch 6350 P48 Internal AC Power Supply P S Component Description Model OmniSwitch 6350 P48 Nominal Input Voltage 90 220 VAC Maximum Out...

Страница 50: ...over Ethernet PoE Ports 48 SFP ports 4 Chassis Width 44 0 cm 17 32 in Total Power Budget 900 W System Power Budget 120 W PoE Power Budget 780 W Chassis Height 4 4 cm 1 73 in 1 RU Chassis Depth 38 6 cm...

Страница 51: ...ogress System fan failure or temperature threshold exceeded PRI Solid Green Solid Amber Off Switch is idle PWR Solid Green Solid Amber Off P S Normal Operation P S Present and Bad P S Not Present 10 1...

Страница 52: ...r wires and is rated between 85 265 VAC region dependent 10 amps with a nominal length of 2 meters The female end terminates in an IEC 60320 C13 attachment plug and the male end termination varies dep...

Страница 53: ...front panel provides a console connection to the switch and is required when logging into the switch for the first time By default this RJ 45 connector provides a DTE console connection Serial Connec...

Страница 54: ...nector Pinout 10 100 Ethernet Port RJ 45 Pinout non PoE Gigabit Ethernet Port RJ 45 Pinout Pin Number Signals as DTE Console Port 1 NC 2 NC 3 RXD 4 Ground 5 Ground 6 TXD 7 NC 8 NC Pin Number Descripti...

Страница 55: ...Guide for information on configuring switch thresholds If the temperature continues to rise and reaches the Danger Threshold the following will occur OK1 LED will display solid Amber The switch will a...

Страница 56: ...Overtemp Condition OmniSwitch 6350 Chassis and Hardware Components page 3 26 OmniSwitch 6350 Hardware Users Guide April 2017...

Страница 57: ...ers different mounting and installation options OmniSwitch 6350 switches may be either table or rack mounted Anti Static Warning Before handling any components free yourself of static by wearing a gro...

Страница 58: ...ended clearance at the front back and sides of the switch as shown below Restricted airflow can cause your switch to overheat which can lead to switch failure Note Clearance is not required at the top...

Страница 59: ...flow required for safe operation of the equipment is not compromised Elevated Operating Ambient Temperatures If installed in a closed or multi unit rack assembly the operating ambient temperature of...

Страница 60: ...f rack mount equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit e g use of power strips General Table Mountin...

Страница 61: ...standard 19 inch rack mount installations Alcatel Lucent does not provide rack mount screws Use the screws supplied by the rack vendor To prevent a rack from becoming top heavy it is recommended that...

Страница 62: ...2017 3 Press the flange and spring clip until the flange clicks into place and the clip is in the in engaged position 4 Secure the flange to the chassis using the attachment screw provided 5 Repeat st...

Страница 63: ...ould lift and position the chassis until the rack mount flanges are flush with the rack post 3 Align the holes in the flanges with the rack holes marked in step 1 4 Once the holes are aligned the seco...

Страница 64: ...s the switch s only disconnect device it should be plugged into an easily accessible outlet In the event that your power cord is lost or damaged refer to the specifications below Powering On a Chassis...

Страница 65: ...up process random characters may briefly display on the console of an OS6350 This is due to an initial baud rate mismatch As soon as the bootrom is initialized the issue is automatically resolved Com...

Страница 66: ...ole port before attempting to change serial connection settings Otherwise an error message will display 1 Enter the modify boot parameters command at the CLI prompt The boot prompt displays Boot 2 To...

Страница 67: ...ompt Boot commit file When the commit file command is used changes will not be enabled until after the next switch reboot 8 You can also save your changes in real time to the switch s running memory b...

Страница 68: ...show chassis command For example show chassis Chassis 1 Model Name 6350 24 PORT COPPER GE Description Virtual Chassis Part Number 903005 90 Hardware Revision 03 Serial Number M338153P Manufacture Dat...

Страница 69: ...6350 LED Status on page 3 21 CLI Commands Used for Monitoring a Chassis show cmm Displays the basic hardware and status information for primary and secondary management modules if applicable show ni D...

Страница 70: ...Monitoring the Chassis Booting OmniSwitch 6350 Switches page 5 6 OmniSwitch 6350 Hardware Users Guide April 2017...

Страница 71: ...are synonymous terms used to describe the powering of attached devices through Ethernet ports This documentation refers to the feature as Power over Ethernet PoE and related CLI commands use the synta...

Страница 72: ...6 CLI Reference Guide Topics and configuration procedures described in this chapter include Power over Ethernet Specifications on page 6 3 Viewing Power Status on page 6 4 Configuring Power over Ether...

Страница 73: ...er 3 OmniSwitch 6350 Chassis and Hardware Components IEEE Standards supported IEEE 802 3at Default PoE administrative status Enabled Default PoE operational status Enabled Models supporting PoE OS6350...

Страница 74: ...n on PoE related CLI commands For detailed information on PoE related commands refer to the OmniSwitch AOS Release 6 CLI Reference Guide Note PoE units support different wattage power supplies If an u...

Страница 75: ...ivate power to PoE capable in a switch enter the corresponding slot number only For example lanpower start 1 If power to a particular port has been disconnected via the lanpower stop command you can r...

Страница 76: ...imum slot wide power allowance By default each switch is authorized by the system software to use up to the maximum watts available from the PoE power supply As with the maximum port power allowance t...

Страница 77: ...have important but not mission critical devices attached If other in the chassis have been configured as critical inline power to high priority is given second priority Critical This value is used for...

Страница 78: ...ty disconnect uses port priority and port number criteria for determining the power status of incoming PDs refer to the examples on pages 6 9 through 6 10 Reminder Priority disconnect applies only whe...

Страница 79: ...t the incoming PD will automatically be granted power over the other devices regardless of its physical port number In order to avoid a power budget deficit another port in the slot is disconnected In...

Страница 80: ...lable to the port in milliwatts Actual power used by the port Current port status Power priority status Power on off status Aggregate slot and chassis management information is also displayed This inf...

Страница 81: ...rate as a single virtual chassis Topics described in the chapter include OmniSwitch 6350 stack overview on page 7 2 Roles within the stack on page 7 3 Stack cabling on page 7 16 Slot numbering on page...

Страница 82: ...ser manually synchronize the switches see Synchronizing Switches in a Stack on page 7 36 for more information operating software and configuration parameters are backed up on all switches in the stack...

Страница 83: ...k one switch in the stack always assumes the primary management role This primary element is responsible for functions such as software and configuration management web based management i e WebView SN...

Страница 84: ...6350 switches is operating normally The stack consists of a pri mary module secondary module and two ele ments operating in idle status The software on all elements in the stack is synchronized The p...

Страница 85: ...consists of a pri mary module and a secondary module The software on both elements in the stack is syn chronized The primary management module fails or is taken offline e g powered off or rebooted by...

Страница 86: ...ation has been cleared For more information on using the lowest MAC address to determine the primary switch in a stack refer to the diagram below Primary Management Module Selection Using the Lowest C...

Страница 87: ...ach element in a stack is assigned a unique slot number Do not assign duplicate slot numbers to elements in a stack Otherwise one or more switches will be forced into pass through mode For more inform...

Страница 88: ...acking cables All switches are currently powered off The user powers on a single switch in the stack In this case the bottom most switch is powered on The user now powers on the remaining switches in...

Страница 89: ...he secondary management module refer to the diagram below Secondary Management Module Selection Using the Stacking Connection to the Primary Switch Note For information on dynamic slot numbering for i...

Страница 90: ...o page 7 12 Primary Slot 1 Slot 3 Slot 4 Secondary Slot 2 Assumes Slot 1 Assumes Slot 3 Assumes Slot 4 Assumes Slot 2 Saved Slot 1 Four OmniSwitch 6350 switches are stacked all switches are connected...

Страница 91: ...s also send and receive traffic on their Ethernet The primary management module is like an NI module with the added task of overall stack management the secondary management module is like an NI with...

Страница 92: ...ot be disrupted Any elements in the stack not operating in pass through mode continue to operate normally The most common reason for one or more switches to enter pass through is duplicate slot number...

Страница 93: ...ed Link A Remote Remote Link B Remote Remote Slot State NI Port State NI Port 1 PRIMARY RUNNING 1 UP 1001 StackA UP 2 StackA 2 SECONDARY RUNNING 2 UP 1 StackB UP 1001 StackB 1001 PASS THRU DUP SLOT 2...

Страница 94: ...the optional reload syntax in the command line reboot the module stack set slot 1001 saved slot 3 reload When the module comes up it assumes the new unique slot position in this case slot 3 and becaus...

Страница 95: ...ASS THRU DUP SLOT 2 UP 1002 StackB UP 2 StackA 1002 PASS THRU DUP SLOT 2 UP 1 StackB UP 1003 StackA 1 PRIMARY RUNNING 1 UP 3 StackB UP 1002 StackA 3 IDLE RUNNING 3 UP 4 StackB UP 1 StackA This disorde...

Страница 96: ...witch at all times This provides effective failover in the event of a stacking link or module failure within the stack The diagram below shows the required stacking cable pattern For detailed informat...

Страница 97: ...es that data will continue to flow throughout the stack even in the event of a connection failure at one of the stacking cables Stacking Cable Redundancy Recovery Following a Stacking Link Failure Dat...

Страница 98: ...nt stacking cable connection exists between the top most and bottom most switches in the stack use the show stack status command For example Redundant cable status present Tokens used 1 Tokens availab...

Страница 99: ...ot number To view the current slot assignments for a stack use the show ni or show module commands The slot number is also displayed on the front panel of each switch by the LED located on the left si...

Страница 100: ...elow for more information on dynamic slot numbering Note As the slot numbers are dynamically assigned boot slot cfg files are auto generated in the flash directory of each switch When modules are subs...

Страница 101: ...namic Slot Numbering Example 2 Slot 4 Idle Slot 3 Idle In this example the bottom switch is elected the primary management module for the stack It can be assumed that this switch has the lowest MAC ad...

Страница 102: ...secondary module positioning it may be preferable for management purposes to have the primary and secondary switches at either the top or the bottom of the stack For this example the primary and secon...

Страница 103: ...amic Slot Numbering Model To clear the boot slot cfg files from the stack s flash directories use the stack clear slot command on all modules and then reboot the stack For example stack clear slot 1 s...

Страница 104: ...or secondary management module Also removing a switch from a stacked configuration can disrupt stack cabling at the rear of the stack When removing a module be sure that stacking link integrity inclu...

Страница 105: ...lowing the steps below 1 Make sure all switches are running the same software version 2 Clear the saved slot information from all incoming modules This will ensure that they are each assigned unique s...

Страница 106: ...ry Note A primary management module reload can also be scheduled for a later time or date For information on scheduling a primary module reload as well as additional command details refer to the OmniS...

Страница 107: ...odule The slot 2 switch is the secondary The user reloads the stack s primary management module by issuing the reload primary command Any data flow on the primary switch s Ethernet is interrupted The...

Страница 108: ...y module reload as well as additional command details refer to the OmniSwitch AOS Release 6 CLI Reference Guide Reloading the Secondary Management Module In a Stack of Three or More In this stack of f...

Страница 109: ...odule The slot 2 switch is the secondary The user reloads the stack s secondary management module by issuing the reload secondary command Any data flow on the secondary switch s Ethernet is inter rupt...

Страница 110: ...d it resumes its previous idle role Although it has the lowest possible saved slot number it does not take over the primary management role In order for this switch to take over the primary role all s...

Страница 111: ...wn good software is propagated to all switches the synchronization process helps ensure effective redundancy across the stack Effects of Saved Slot Number Information on the Reload Process Depending o...

Страница 112: ...do not have saved slot information The primary management role will be given to the switch with the lowest saved slot number The secondary management role will be given to the switch with the second l...

Страница 113: ...in the stack and the third from top switch in the stack are reloaded simultaneously a problem will occur The switch between the two non adjacent switches will become isolated and the virtual chassis w...

Страница 114: ...s in the stack are synchronized Otherwise data flow and switch management functions may be interrupted due to incorrect or outdated software when a switch takes over the primary management role For mo...

Страница 115: ...gement module The slot 2 switch is the secondary A takeover is initiated by the user the primary man agement module is automatically reloaded Any data flow on the primary switch s Ethernet is interrup...

Страница 116: ...d at all times To determine whether a stack is in need of synchronization use the show running directory command For example show running configuration CONFIGURATION STATUS Running CMM PRIMARY CMM Mod...

Страница 117: ...mechanism is available to recover the non operational sub stack A method of detecting a stack split in a remote stacking topology where the stack may consist of elements located in different physical...

Страница 118: ...a mismatch between the two then that indicates the presence of an active stack in the network which is disconnected from the current stack In this condition the stack element will monitor 3 5 such co...

Страница 119: ...one element at a time from the protection state until all elements are active Once complete the primary will generate a trap indicating the stack has been recovered Stack Split Example 1 Stack split...

Страница 120: ...guration and status information for the switch chassis show cmm Displays basic hardware and status information for primary and secondary management modules operating in the stack show ni Displays basi...

Страница 121: ...OS Release 6 CLI Reference Guide CMM Commands reload takeover install debug chassis auto reboot show running directory show reload show microcode Chassis Management and Monitoring Commands show system...

Страница 122: ...Monitoring the Stack Managing OmniSwitch 6350 Stacks page 7 42 OmniSwitch 6350 Hardware Users Guide April 2017...

Страница 123: ...essentielles et aux autres provisions de la Directive 2004 108 EC EMC 2006 95 CE LVD 91 263 CEE quipements terminaux de t l communications le cas ch ant 1999 5 EC R TTE le cas ch ant Deutsch Diese Aus...

Страница 124: ...Hazardous Substance Table California Proposition 65 Warning WARNING This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm Produ...

Страница 125: ...onic Equipment WEEE Statement The product at end of life is subject to separate collection and treatment in the EU Member States Norway and Switzerland and therefore marked with the symbol Treatment a...

Страница 126: ...UL GS Mark Germany NOM 019 SCFI Mexico EN 60825 1 Laser EN 60825 2 Laser CDRH Laser CB Certification per IEC 60950 1 Second Edition EMC Standards FCC Part 15 CFR 47 Class A ICES 003 Class A EN 55022 C...

Страница 127: ...elevision reception the user is encouraged to try to correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receive...

Страница 128: ...may arise When such trouble occurs the user may be required to take corrective actions Class A Warning for Taiwan and Other Chinese Markets This is a Class A Information Product When used in a residen...

Страница 129: ...des Gewichts kann das Anheben ohne Unterst tzung zu Personensch den f hren Heben Sie das Chassis aus den Knien und halten Sie den R cken gerade wenn Sie beim Anheben des Chassis assistieren Espa ol S...

Страница 130: ...egarder fixement l int rieur de ces ouvertures Installez les caches connecteurs pr vus cet effet Deutsch Hinweise zur unsichtbaren Laserstrahlung Die Laser strahlen an der Blenden ffnung unsichtbares...

Страница 131: ...Corpo ration P N CT 940CH for crimping Fran ais Pour viter tout risque de choc lectrique Ne jamais rendre inop rant le conducteur de masse ni utiliser l quipement sans un conducteur de masse ad quate...

Страница 132: ...la cual usted debe estar enterado al trabajar con los componentes de dotaci n f sica en este sistema Usted debe leer esta gu a antes de insta lar usar o mantener este equipo Restricted Access Location...

Страница 133: ...let avant toute intervention hard ware Deutsch Hinweise zur ESD Elektrostatischen Aufladung Weil elektrostatische Aufladung ESD Teile der Anlage besch digen k nnten m ssen sie sich selbst erden bevor...

Страница 134: ...rtencia de radiaci n l ser invisible Los lasers emiten radiaci n invisible de la apertura abierta cuando no se conecta ning n cable de fibra ptica Al quitar los cables no mire fijamente en las abertur...

Страница 135: ...instalar de usar o de mantener este equipo Advertencia de acceso restringido Este equipo se debe instalar en una ubicaci n que restrinja el acceso Una ubicaci n con acceso restrin gido es una donde e...

Страница 136: ...Instrucciones de seguridad en espa ol Regulatory Compliance and Safety Information page A 14 OmniSwitch 6350 Hardware Users Guide April 2017...

Отзывы: