Site requirements for wall mount installations
Overview
This topic describes site requirements for installing RRHs on a wall.
Prepare site for wall mount installation
The following are required to prepare a site for wall mount installation of the cabinet.
•
Install DC power runs
•
Install grounding system
•
Install RF runs
•
DC Distribution/Fiber Management Box provided by Alcatel-Lucent
•
fiber cable
Wall mounting shall comply with the applicable architectural codes listed on listed earlier
in this chapter.
Holes shall be pre-drilled with (customer supplied) anchor hardware, if mounting to a
concrete wall.
Unistruts shall be in place, if required for mounting cabinet.
Cabinet wall mounting hardware
The following is an example of customer-supplied mounting hardware that is required to
mount struts to a solid concrete wall:
•
1.5 inch x 1.5 inch Unistrut® or equivalent struts (2)
•
M10 (3/8 inch) x 100 mm (4inch) long Power-Stud™ (formerly called Rawl-Stud®)
or equivalent anchor bolts for solid concrete walls (4)
•
M10 (3/8 inch) nuts (4)
•
M10 (3/8 inch) flat washers (8)
•
M10 (3/8 inch) spring nuts from the same manufacturer as the struts (4)
•
M10 (3/8 inch) x 80 mm (1 inch) long hex-head bolts (4)
•
M10 (3/8 inch) lock washers (4).
Basic site preparation requirements and footprints for
RRHs
Site requirements for RRHs
Site requirements for wall mount installations
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................