4-32
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
Installation
Installation
Mount surge arrestor (optional)
WARNING
Fall hazard
Falls can occur when working at heights resulting in serious personal injury or death.
To prevent a fall when working at heights (ladder, scaffold, manlift, roof etc.) follow safe
work practices and wear appropriate fall protection equipment.
Although optional, Alcatel-Lucent strongly recommends for outdoor deployments, that
when the backhaul connection is configured for electrical Ethernet (GBE
10/100/1000BaseT) a surge arrestor is installed, as the electrical SFP does not provide
surge protection.
Follow these steps to attached the surge arrestor bracket to a wall and mount the optional
external surge arrestor onto the surge arrestor bracket.
...................................................................................................................................................................................................
1
At the selected mounting location for the surge arrestor, mark the points on the wall for
the mounting bracket anchor holes. See drill hole pattern below to use as a guide:
Tip:
The surge arrestor mounting bracket can be used as a template to mark the points
on the wall for the fixing holes.
...................................................................................................................................................................................................
2
Drill the upper hole and lower hole at the marked points to the appropriate depth. Insert
screw anchor plugs into the drilled holes and, using a hammer, tap home until the plugs
are flush with the wall.
...................................................................................................................................................................................................
3
Align the surge arrestor mounting bracket bolt holes with the drilled wall anchor holes.
Screw the upper and lower bolts into the wall fixings to the appropriate depth so that the
mounting bracket is securely attached to the wall.
30 mm
(1.2 inches)