4-27
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
Installation
Installation
....................................................................................................................................................................................................................................
Guidelines for installing two 9764 CMCOs, one on top of the other
If the 9764 CMCOs are mounted one on top of the other, a certain distance between them
must be considered in order to prevent the bottom CMCO from overheating the top one.
There are two cases to be taken into account:
an air baffle is used when installing the two modules - the minimum separation
distance between the CMCOs is 50 cm, measured from the top of the lower CMCO to
the bottom of the upper CMCO, or
the two modules are mounted without using an air baffle - the minimum separation
distance is 2 m, measured from the top of the lower CMCO to the bottom of the upper
CMCO.
Note:
It is in the responsibility of the customer to provide an air baffle for separation
distances of 50 cm to 2m.
How to continue
After mounting the 9764 CMCO onto a pole the cables need to be connected. Continue
with the
Chapter 5, “Cabling”
chapter.