Installation
Pre-installation cabling
....................................................................................................................................................................................................................................
Contact springs
Cable gland
Contact springs
Ethernet cable
...................................................................................................................................................................................................
5
Feed the Ethernet cable through the gland opening on the backhaul module and insert the
Ethernet cable connector into the SFP transceiver in the port labelled “BH
1”.
BH2 port
BH1 port
...................................................................................................................................................................................................
6
Loosely insert the gland assembly into the gland housing.
Note:
The gland assembly with cable may need to be turned slightly in order to fully
slide into the gland housing before the compression nut can be screwed on.
...................................................................................................................................................................................................
7
Screw the rounded compression nut back onto the main body of the gland. Use an
adjustable or open-end wrench to tighten the compression nut.
Important!
It is recommended that the compression nut is torqued to 2.5 N.m (22.1
lb.in) in order to create a watertight seal and avoid a potential loose connection.