Installation
Pre-installation cabling
....................................................................................................................................................................................................................................
Important!
When securing cables ensure the following to avoid cable damage:
Secure cables with tie wraps. Use additional tie wraps wherever necessary for
neatness
All cables should be run parallel with no twisting or tangled cables
Avoid excessive tension on the cable.
E
...
N
...
D
.....
O
...
F
.....
S
...
T
...
E
..
P
...
S
.....................................................................................................................................................................
Cable the optional external surge arrestor
Follow these steps to connect the Ethernet cables to the external surge arrestor.
...................................................................................................................................................................................................
1
On the surge arrestor, unscrew the lower weatherized strain relief connector and locking
nut from the surge arrestor.
...................................................................................................................................................................................................
2
Carefully feed the end of Ethernet cable coming from the Customer Network Interface
Device through the unscrewed lower strain relief connector.
...................................................................................................................................................................................................
3
Plug the Ethernet cable RJ45 connector into the lower connector on the arrestor. Screw
the weatherized strain relief connector back onto the arrestor and tighten.
...................................................................................................................................................................................................
4
At the top of the arrestor, unscrew the upper weatherized strain relief connector from the
surge arrestor.
...................................................................................................................................................................................................
5
Carefully feed the end of Ethernet cable coming from the 9764 CMCO through the upper
strain relief connector.
...................................................................................................................................................................................................
6
Plug the Ethernet cable RJ45 connector into the upper connector on the arrestor. Screw
the weatherized strain relief connector back onto the arrestor and tighten.
...................................................................................................................................................................................................
7
Finally, secure the Ethernet cable to the wall/pole.