System Commands
Page 462
7950 SR OS Basic System Configuration Guide
mc-ring peer ip-address ring sync-tag ring-node
[
ring-node-name
[
detail
|
statistics
] ]
mc-ring global-statistics
Context
show>redundancy>multi-chassis
Description
This command displays multi-chassis ring information.
Parameters
ip-address —
Specifies the address of the multi-chassis peer to display.
ring sync-tag —
Specifies a synchronization tag to be displayed that was used while synchronizing this port
with the multi-chassis peer.
node ring-node-name —
Specifies a ring-node name.
global-statistics —
Displays global statistics for the multi-chassis ring.
detail —
Displays detailed peer information for the multi-chassis ring.
Output
Show mc-ring peer ip-address ring Output —
The following table describes mc-ring peer ip-address
ring output fields.
Label
Description
Sync Tag
Displays the synchronization tag that was used while synchronizing this port
with the multi-chassis peer.
Oper State
noPeer —
The peer has no corresponding ring configured.
connected —
The inband control connection with the peer is operational.
broken —
The inband control connection with the peer has timed out.
conflict —
The inband control connection with the peer has timed out
but the physical connection is still OK; the failure of the inband signaling con-
nection is caused by a misconfiguration. For example, a conflict between the
configuration of this system and its peer, or a misconfiguration on one of the
ring access node systems.
testingRing —
The inband control connection with the peer is being set
up. Waiting for result.
waitingForPeer —
Verifying if this ring is configured on the peer.
configErr —
The ring is administratively up, but a configuration error
prevents it from operating properly.
halfBroken —
The inband control connection indicates that the ring is
broken in one direction (towards the peer).
localBroken —
The inband control connection with the peer is known to
be broken due to local failure or local administrive action.
shutdown —
The ring is shutdown.
Failure Reason
Displays the reason of the failure of the operational state of a MC ring.
Содержание 7950 XRS Series
Страница 8: ...Page 8 7950 SR OS Basic System Configuration Guide List of Tables...
Страница 10: ...Page 10 7950 SR OS Basic System Configuration Guide List of Figures...
Страница 14: ...Preface Page 14 7950 SR OS Basic System Configuration Guide...
Страница 46: ...VI Editor Page 46 7950 SR OS Basic System Configuration Guide...
Страница 76: ...File Management Tasks Page 76 7950 SR OS Basic System Configuration Guide...
Страница 78: ...File Command Reference Page 78 7950 SR OS Basic System Configuration Guide...
Страница 92: ...Basic Command Reference Page 92 7950 SR OS Basic System Configuration Guide show system candidate...
Страница 172: ...Basic CLI Commands Page 172 7950 SR OS Basic System Configuration Guide...
Страница 184: ...Configuration Notes Page 184 7950 SR OS Basic System Configuration Guide...
Страница 214: ...DNS Configuration Commands Page 214 7950 SR OS Basic System Configuration Guide...
Страница 220: ...Show Commands Page 220 7950 SR OS Basic System Configuration Guide...
Страница 494: ...System Commands Page 494 7950 SR OS Basic System Configuration Guide...
Страница 500: ...Standards and Protocols Page 500 Standards and Protocols...
Страница 502: ...Index Page 502 7950 SR OS Basic System Configuration Guide system parameters 252 system time elements 256 timing 294...