Facility Alarms
7950 SR OS System Management Guide
Page 449
Table 46: Alarm Name/Raising Event, Cause, Effect and Recovery
Alarm *1
Alarm Name/Raising
Event
Cause
Effect
Recovery
7-2001-1
tmnxEqCardFailure
Generated when one of the
cards in a chassis has failed.
The card type may be IOM
(XCM), MDA (XMA), SFM,
CCM, CPM, Compact Flash,
etc. The reason is indicated in
the details of the log event or
alarm, and also available in the
tmnxChassisNotifyCardFailure
Reason attribute included in the
SNMP notification.
The effect is dependant
on the card that has
failed. IOM (XCM) or
MDA (XMA) failure
will cause a loss of
service for all services
running on that card. A
fabric failure can impact
traffic to/from all cards.
Before taking any
recovery steps
collect a tech-
support file, then
try resetting
(clear) the card. If
that doesn't work
then try removing
and then re-
inserting the card.
If that doesn't
work then replace
the card.
7-2003-1
tmnxEqCardRemoved
Generated when a card is
removed from the chassis. The
card type may be IOM (XCM),
MDA (XMA), SFM, CCM,
CPM, Compact Flash, etc.
The effect is dependant
on the card that has been
removed. IOM (XCM)
or MDA (XMA)
removal will cause a
loss of service for all
services running on that
card. A fabric removal
can impact traffic to/
from all cards.
Before taking any
recovery steps
collect a tech-
support file, then
try re-inserting
the card. If that
doesn't work then
replace the card.
7-2004-1
tmnxEqWrongCard
Generated when the wrong type
of card is inserted into a slot of
the chassis. Even though a card
may be physically supported by
the slot, it may have been
administratively configured to
allow only certain card types in
a particular slot location. The
card type may be IOM (XCM),
MDA (XMA), SFM, CCM,
CPM, Compact Flash, etc.
The effect is dependant
on the card that has been
incorrectly inserted.
Incorrect IOM (XCM)
or MDA (XMA)
insertion will cause a
loss of service for all
services running on that
card.
Insert the correct
card into the
correct slot, and
ensure the slot is
configured for the
correct type of
card.
7-2005-1
tmnxEnvTempTooHigh
Generated when the
temperature sensor reading on
an equipment object is greater
than its configured threshold.
This could be causing
intermittent errors and
could also cause
permanent damage to
components.
Remove or power
down the affected
cards, or improve
the cooling to the
node. More
powerful fan
trays may also be
required.
Содержание 7950 SR
Страница 10: ...Page 10 7950 SR OS System Management Guide List of Figures...
Страница 14: ...About This Guide Page 14 7950 SR OS System Management Guide...
Страница 16: ...Alcatel Lucent 7950 SR Router Configuration Process Page 16 7950 SR OS System Management Guide...
Страница 56: ...Configuration Notes Page 56 7950 SR OS System Management Guide...
Страница 88: ...Configuring Login Controls Page 88 7950 SR OS System Management Guide...
Страница 106: ...Security Command Reference Page 106 7950 SR OS System Management Guide...
Страница 206: ...Distributed CPU Protection Commands Page 206 7950 SR OS System Management Guide...
Страница 244: ...Debug Commands Page 244 7950 SR OS System Management Guide...
Страница 254: ...Configuration Notes Page 254 7950 SR OS System Management Guide...
Страница 276: ...SNMP Security Commands Page 276 7950 SR OS System Management Guide...
Страница 296: ...Show Commands Page 296 7950 SR OS System Management Guide...
Страница 322: ...Configuration Notes Page 322 7950 SR OS System Management Guide...
Страница 358: ...Log Management Tasks Page 358 7950 SR OS System Management Guide...
Страница 454: ...Facility Alarm List Page 454 7950 SR OS System Management Guide...
Страница 460: ...Standards and Protocols Page 460 Standards and Protocols...