.4.1b Connections to start the equipment by one clean relay switch:
Service Line 1 (Pushbutton A): from pin 1 (COM 1) of the J2 connector, take a wire to the actuator of service line 1. If
operation mode is “normally open”, take the switching wire to the 1 actuator from pin 2 (N.O. 1).
If operation mode must be “normally closed”, take such wire from pin 3 (N.C. 1).
Service Line 2 (Pushbutton B): from pin 4 (COM 1) of the J2 connector, take a wire to the actuator of service line 2. If
operation mode is “normally open”, take the switching wire to the 2 actuator from pin 5 (N.O. 2).
If operation mode must be “normally closed”, take such wire from pin 6 (N.C. 2).
It is possible to disable coin acceptance in any of the following two ways:
Electronically - Pins 7/8 of green connector J2: provide any Vdc (+) or Vac (line value) to pin 7, and respectively
0Vdc (-) or Neutral Vac to pin 8.
Mechanically - move to OFF the dip-switches located on the coin acceptor. Move them back to ON when you want to
resume coin acceptance.