Alberici TimeboxB ACS Скачать руководство пользователя страница 13

TIMEBOX ACS ALBERICI 
Rev. 1.05 

Manual 

Page 
13 

 

OK 

Saving  

Settings 

 

DOWN 

UP 

OK 

DOWN 

OK 

DOWN 

UP 

OK 

Price of serv. 1:

 

0,50 

 

 
7.3.2.3.1      Set up peripheral units 

 

 

 

 
 
 

 
 

 

(*) Make use of 
the UP / DOWN 
keys to modify  

 

 

         

 

 

7.3.2.3.1a      Set up the Service Parameters (price / duration) 

 

 

 

Press the               key: 

if value must be modified, press again the             key. 

 

It is now possible to increase the price by pressing repeatedly the 

  key, or decrease it by the                 key. Each touch 

changes the price value by 

0,05 €

 step: 

 

Notice: 

holding down the key for 4 seconds, the increase/decrease variation runs faster.  

 

Press then 

to confirm the chosen value and carry on to modify the pulse time lengt:                                     . 

 

The pulse duration (i.e. the service dispensing time) can be increased by holding down the  

 key, or it can be decreased 

by the 

key. Each touch changes the time value by 0,01 seconds (10 msec) steps: 

Notice: 

holding down the key for 4 seconds, the increase/decrease variation runs faster  

Once the desired value has been reached, it can be confirmed by the  

key. 

 

The display will now show: 

 

If the Service Line 2 must be also used, repeat the setting operations described above for the Service line 1,   

or else  press repeatedly the 

key until obtaining the exit option: 

 

To save the settings, press 

: the                                     message will briefly appear. 

        

 
 
 

OK 

Peripheral units 

set up

 

(*) 

0,50

 

OK

 

OK 

OK

 

< 2,00 >      1,00

 

See  7.3.2.3.1a 

Set up Service 

Parameters

 

5    < 10 >  20     50      100

 

 NO    OK    OK    OK     OK

 

< 2,00 >    1,00 

0,50

 

NO 

OK 

OK

 

Coin Acceptor 

set up

 

Exit

 

 2,00 

< 1,00 >        0,50

 

OK 

OK 

OK

 

2,00 

 1,00        < 0,50 > 

OK 

 NO 

OK

 

Price of serv. 1:

 

0,45 

 

DOWN 

Price of serv. 1:

 

0,50 

 

UP 

Price of serv. 1:

 

0,55 

 

Pulse length 1:            
0,29 s

 

DOWN 

Pulse length

 

1:     

0,30 s

 

UP 

Pulse length 1:    
0,31 s

 

Exit

 

Set up 

Service Parameters

 

Initialize 

Cashless

 

 

See  7.3.2.3.1b 

Pulse length

 

1:     

0,30 s

 

Price of serv. 2:

 

0,50 

 

Содержание TimeboxB ACS

Страница 1: ...ACTIVE ONE ALBERICI Manual Rev 1 00 Page1 TimeboxBACS Pay for time box with RFID reader 2 Service Lines Operator s manual Rev 1 05 User Manual...

Страница 2: ...heless it is not possible to assure at any time the exact correspondence of the descriptions to the product features Alberici SpA shall not be held liable by the User for any damage losses or third pa...

Страница 3: ...peration 11 7 Product disposal 12 8 Terms of Guarantee 12 9 Customer Service 12 STORICO REVISIONI Revisione n Data Modifica Note Creazione 1 00 05 10 12 Creazione Rev 1 02 04 04 14 ActiveOne scheda MK...

Страница 4: ...ys ACR programmer interface This product has been packed with the utmost care If you receive it damaged or incomplete please notify immediately your findings to the Carrier and collect it only under c...

Страница 5: ...uring transport or whether any anomalies appear In this case report it immediately to the forwarder driver and have the complaint transcribed on the receipt document before signing If it is necessary...

Страница 6: ...2 Mounting It is recommended to install it away from direct weather agents such as rain hail and sunlight Praticare 6 fori sulla parete o su un sostegno in metallo o legno in corrispondenza dei fori p...

Страница 7: ...li ccTalk line for RFID ACS reader and coin acceptor The output signals from pins 2 and 6 of the P5 connector are in TTL format they drive the input circuit of the Servo p c b to activate the relay re...

Страница 8: ...straight to the relevant actuator i e electrical motor solenoid a s o Connect the other end to pin 1 COM 1 of J2 connector If operation mode is normally open take the switching wire to the 1 actuator...

Страница 9: ...Pushbutton B from pin 4 COM 1 of the J2 connector take a wire to the actuator of service line 2 If operation mode is normally open take the switching wire to the 2 actuator from pin 5 N O 2 If operati...

Страница 10: ...ctivated When the device gets switched on for the first time the RFID key ACS reader flashes red to signal that it must be initialized see section 7 3 2 3 1b The Timebox can be used also if the ACS ha...

Страница 11: ...ind the display SW UP scroll functions forward and increase values SW DOWN scroll functions backward and decrease values SW OK confirm options and values 7 3 2 MENU STRUCTURE 7 3 2 1 SHOW ACCOUNT RECO...

Страница 12: ...acceptor set up Peripheral units set up See 7 3 2 3 3 See 7 3 2 3 2 Write your 16 digits message to appear on the display when in stand by condition See Section 7 3 2 3 1 Only if ACS reader is present...

Страница 13: ...touch changes the time value by 0 01 seconds 10 msec steps Notice holding down the key for 4 seconds the increase decrease variation runs faster Once the desired value has been reached it can be conf...

Страница 14: ...en complete the confirmation message gets displayed If a second Master key or the Service key must be created repeat the process described Or else choose the Service Key option in the menu to initiali...

Страница 15: ...wing revolving messages will be displayed should the Key be spoiled or invalid the following message will be displayed KEY NOT ENABLED Insert Key to be initialized Insert Key to be initialized DO NOT...

Страница 16: ...place so preserving secrecy NOTICE when DEFAULT CONFIGURATION is restored the PIN code gets reset to 0000 If the entered PIN is not correct the User is given another 4 tries before the board gets blo...

Страница 17: ...nal amount of time will be added up to the remaining fraction of the time already bought 8 2 Keys with sufficient credit Introducing an RFID key charged with sufficient credit or as many coins as to r...

Страница 18: ...th the prescribed safety requirements intentional or unwilled tampering wrong or careless use or maintenance non compliance with precautions prescribed see Chapter 4 Caution natural disasters vandalis...

Страница 19: ...TIMEBOX ACS ALBERICI Rev 1 05 Manual Page 19...

Страница 20: ......

Страница 21: ...1 05 Manual Page 21 NOTICE Alberici S p A reserves the right to change the features and the specifications to the equipment described at any time and without notice in the pursuit of the incessant imp...

Страница 22: ...Fax 39 051 944 594 Via Ca Bianca 421 40024 Castel San Pietro Terme BO ITALY Progettazione e produzione di sistemi di pagamento accessori per videogames e macchine vending Design and manufacture of pa...

Отзывы: