Alberici TimeboxB ACS Скачать руководство пользователя страница 14

 

7.3.2.3.1a      Cashless setup

 

 

 

When first powering the unit on, the RFID ACS Reader flashes red, to show that it must be initialized.    

 

-   Initialize the ACS Reader 

Edit a 6-digit PIN code, write it down and keep it in a safe place.

 

 

 

 
 

 

 
 

(*) The code must consist of 6 alphanumeric characters: press the OK button, the cursor sets to the  
first digit: with UP or DOWN, choose the letter or digit to be entered, and confirm with the OK button.  
The cursor will move to the next digit.  When confirming digit n. 6, the request to confirm the entered  
code appears. By selecting the "<" symbol and pressing OK, the last character entered gets deleted. 

 

If RFID keys must be used that have already been initialized on another Alberici cashless reader,  
take care to enter the same 6-digit PIN of the device in which they were initialized. 

 

(**) If the same alphanumeric sequence entered before is wrongly re-written, the message appears: 

and after 3 "the request to enter the correct code is presented again. 

 

                  To  protect the safety of the Device owner, it is no longer possible to change 
                the 6-digit code after it has been confirmed.

 

 

-   Initialize the Master and Service Keys after having initialized the RFID ACS Reader 

Following to the initialization of the ACS Cashless reader, the Master key (Owner - generally the black one) and the Service key 
(Operator - generally yellow) can be initialized as well.  
NOTICE: initialization of the keys can be postponed. In this case, see next page flow chart.  
Insert the Master key and press the OK button: the display will prompt to enter the PIN code. After entering the last character, the 
display will require confirmation of the same code. Insert the code again: the initialization  
of the Master key will be started. When complete, the confirmation message gets displayed: 
If a second Master key or the Service key must be created, repeat the process described. 
Or else, choose the Service Key option in the menu to initialize the related key (Operator - generally white). To exit, remove the key 

and wait for the device to return to tits stand-by condition. 

 

-   Initialize the User Keys

 

To initialize the User keys, exit the menu, insert the Master key or the Service key (already initialized on the same Timebox) in the 

ACS key reader. The "Service Menu" will open: navigate by the "+" button in the menu shown, until finding  the option INITIALIZE 
KEYS: then press OK. Remove now the Master / Service Key, insert one User Key, and follow the instructions appearing on display: 
 

 

 

 

Remove the key and insert a new one, and so on until you have initialized all the keys that can be used on this player. To exit, 
remove the last key and wait for the device to return to the stand-by condition. 

 

-   Load credit on User Keys

 

Once User Keys have been initialized, they can be loaded with credit in three ways: 

1) In case of self-service top-up: 
- introduce the coins into the coin mechanism of the Timebox; 

- enter the User Key 
- press the lit up pushbutton: the amount introduced will be loaded on the key, and the display will show the total credit available. 

 

2) Using the ACR user key programmer (K-P4N-000007), from 
connect to a PC and use the ccTalk-mifare credit loading software 

supplied with the ACR programmer. 
The programmer and the relative software allow to cancel the configuration 
of keys that have been programmed incorrectly. 

 

 
3) By means of the KEY_LOADER ONE ACS (TB-L6A2) credit-uploading device: 

 

 
 

 
 

Key 

initialized!

 

Do not remove  

the Key..

 

Key 

initialized! 

 

Insert User Key 

Please wait

 

Remove the Key 

Insert 
 Key..

 

Enter  PIN 
_ _ _ _ _ _

 

 

Antenna has been 

initialized!

 

Wrong  

confirmation!

 

Initialize Cashless 

antenna

 

Enter  

PIN code

 

Confirm  

PIN code

 

Write down 

 PIN code

 

Содержание TimeboxB ACS

Страница 1: ...ACTIVE ONE ALBERICI Manual Rev 1 00 Page1 TimeboxBACS Pay for time box with RFID reader 2 Service Lines Operator s manual Rev 1 05 User Manual...

Страница 2: ...heless it is not possible to assure at any time the exact correspondence of the descriptions to the product features Alberici SpA shall not be held liable by the User for any damage losses or third pa...

Страница 3: ...peration 11 7 Product disposal 12 8 Terms of Guarantee 12 9 Customer Service 12 STORICO REVISIONI Revisione n Data Modifica Note Creazione 1 00 05 10 12 Creazione Rev 1 02 04 04 14 ActiveOne scheda MK...

Страница 4: ...ys ACR programmer interface This product has been packed with the utmost care If you receive it damaged or incomplete please notify immediately your findings to the Carrier and collect it only under c...

Страница 5: ...uring transport or whether any anomalies appear In this case report it immediately to the forwarder driver and have the complaint transcribed on the receipt document before signing If it is necessary...

Страница 6: ...2 Mounting It is recommended to install it away from direct weather agents such as rain hail and sunlight Praticare 6 fori sulla parete o su un sostegno in metallo o legno in corrispondenza dei fori p...

Страница 7: ...li ccTalk line for RFID ACS reader and coin acceptor The output signals from pins 2 and 6 of the P5 connector are in TTL format they drive the input circuit of the Servo p c b to activate the relay re...

Страница 8: ...straight to the relevant actuator i e electrical motor solenoid a s o Connect the other end to pin 1 COM 1 of J2 connector If operation mode is normally open take the switching wire to the 1 actuator...

Страница 9: ...Pushbutton B from pin 4 COM 1 of the J2 connector take a wire to the actuator of service line 2 If operation mode is normally open take the switching wire to the 2 actuator from pin 5 N O 2 If operati...

Страница 10: ...ctivated When the device gets switched on for the first time the RFID key ACS reader flashes red to signal that it must be initialized see section 7 3 2 3 1b The Timebox can be used also if the ACS ha...

Страница 11: ...ind the display SW UP scroll functions forward and increase values SW DOWN scroll functions backward and decrease values SW OK confirm options and values 7 3 2 MENU STRUCTURE 7 3 2 1 SHOW ACCOUNT RECO...

Страница 12: ...acceptor set up Peripheral units set up See 7 3 2 3 3 See 7 3 2 3 2 Write your 16 digits message to appear on the display when in stand by condition See Section 7 3 2 3 1 Only if ACS reader is present...

Страница 13: ...touch changes the time value by 0 01 seconds 10 msec steps Notice holding down the key for 4 seconds the increase decrease variation runs faster Once the desired value has been reached it can be conf...

Страница 14: ...en complete the confirmation message gets displayed If a second Master key or the Service key must be created repeat the process described Or else choose the Service Key option in the menu to initiali...

Страница 15: ...wing revolving messages will be displayed should the Key be spoiled or invalid the following message will be displayed KEY NOT ENABLED Insert Key to be initialized Insert Key to be initialized DO NOT...

Страница 16: ...place so preserving secrecy NOTICE when DEFAULT CONFIGURATION is restored the PIN code gets reset to 0000 If the entered PIN is not correct the User is given another 4 tries before the board gets blo...

Страница 17: ...nal amount of time will be added up to the remaining fraction of the time already bought 8 2 Keys with sufficient credit Introducing an RFID key charged with sufficient credit or as many coins as to r...

Страница 18: ...th the prescribed safety requirements intentional or unwilled tampering wrong or careless use or maintenance non compliance with precautions prescribed see Chapter 4 Caution natural disasters vandalis...

Страница 19: ...TIMEBOX ACS ALBERICI Rev 1 05 Manual Page 19...

Страница 20: ......

Страница 21: ...1 05 Manual Page 21 NOTICE Alberici S p A reserves the right to change the features and the specifications to the equipment described at any time and without notice in the pursuit of the incessant imp...

Страница 22: ...Fax 39 051 944 594 Via Ca Bianca 421 40024 Castel San Pietro Terme BO ITALY Progettazione e produzione di sistemi di pagamento accessori per videogames e macchine vending Design and manufacture of pa...

Отзывы: