Alberici TimeboxB ACS Скачать руководство пользователя страница 10

 

Access to  

Service Menu…

 

ACCOUNTS

 

 

7.

 

Operation 

7.1

 

Getting started 

Switch the machine on: the display will lit on and will show the following message: 

The machine is ready to operate by the following default preset values: 

 

The Timebox B is able to simultaneously control two independent pay-for-time service lines, having different price and time 
length. When introducing one coin or the RFID key, the corresponding credit will be displayed. If such amount is enough to 

activate at least one of the two service lines, this one (or both of them) shall be proposed, and the relevant pushbutton light 
will change from blue to green colour. 
When pressing the button for service line A (or service line B), the display will show briefly paid amount and total time, then 

the relevant relay will switch on, and remain on, for the set time. The display will show the progress of the count- down, and 
the pushbutton will be blinking until end of service time. 
If it has been introduced a larger amount than the price for the service, the proportionally larger activation time shall be 
displayed and activated. 

 

When the device gets switched on for the first time, the RFID key ACS reader flashes red, to signal that it must be 
initialized. (see section 7.3.2.3.1b). The Timebox can be used also if the ACS has not been initialized. 

 

7.2

 

Access through Master/Service Key 

Insert the service key (Master or Service) in the RFID reader to view the audits and to initialize User keys (or else access 
the menu using the on-board pushbuttons). 

     The Accounts menu appears and the           pushbutton lits up green:  

 

Hold down for 4” the    

        pushbutton to  

get access to the Accounts sub-menu. 

 

        Briefly hold down the          pushbutton to show: 

 

Hold down the 

   

for at least 4” to get

     

       

access to the sub-menu (see sect. 7.3.2.3.1b). 

 

         Press again the         pushbutton to return to: 

Remove the Master/Service Key to exit the Service menu. The standby message appears: 
 

Accounts

press the pushbutton for at least “2 to enter to the audit details

                         Press briefly and repeatedly the  

pushbutton to show: 

              

 

     

 

   

 

If no Master/Service key is at hand, the records can be cancelled also by entering the menu by the on-board buttons. 

 

Totals IN

 

xxx,xx €

 

            Totals OUT

 

                           

xxx,xx €

 

Reset  

Partial records

 

price of service = 0,50 €

 

pulse length = 30 sec 

Line 2: 

price of service = 0,50 €

 

pulse length = 30 sec 

Line 1

System  

in service

 

Totals IN

 

                  

xxx,xx €

 

System in

 

service

 

INITIALIZE  

CASHLESS

 

ACCOUNTS

 

Содержание TimeboxB ACS

Страница 1: ...ACTIVE ONE ALBERICI Manual Rev 1 00 Page1 TimeboxBACS Pay for time box with RFID reader 2 Service Lines Operator s manual Rev 1 05 User Manual...

Страница 2: ...heless it is not possible to assure at any time the exact correspondence of the descriptions to the product features Alberici SpA shall not be held liable by the User for any damage losses or third pa...

Страница 3: ...peration 11 7 Product disposal 12 8 Terms of Guarantee 12 9 Customer Service 12 STORICO REVISIONI Revisione n Data Modifica Note Creazione 1 00 05 10 12 Creazione Rev 1 02 04 04 14 ActiveOne scheda MK...

Страница 4: ...ys ACR programmer interface This product has been packed with the utmost care If you receive it damaged or incomplete please notify immediately your findings to the Carrier and collect it only under c...

Страница 5: ...uring transport or whether any anomalies appear In this case report it immediately to the forwarder driver and have the complaint transcribed on the receipt document before signing If it is necessary...

Страница 6: ...2 Mounting It is recommended to install it away from direct weather agents such as rain hail and sunlight Praticare 6 fori sulla parete o su un sostegno in metallo o legno in corrispondenza dei fori p...

Страница 7: ...li ccTalk line for RFID ACS reader and coin acceptor The output signals from pins 2 and 6 of the P5 connector are in TTL format they drive the input circuit of the Servo p c b to activate the relay re...

Страница 8: ...straight to the relevant actuator i e electrical motor solenoid a s o Connect the other end to pin 1 COM 1 of J2 connector If operation mode is normally open take the switching wire to the 1 actuator...

Страница 9: ...Pushbutton B from pin 4 COM 1 of the J2 connector take a wire to the actuator of service line 2 If operation mode is normally open take the switching wire to the 2 actuator from pin 5 N O 2 If operati...

Страница 10: ...ctivated When the device gets switched on for the first time the RFID key ACS reader flashes red to signal that it must be initialized see section 7 3 2 3 1b The Timebox can be used also if the ACS ha...

Страница 11: ...ind the display SW UP scroll functions forward and increase values SW DOWN scroll functions backward and decrease values SW OK confirm options and values 7 3 2 MENU STRUCTURE 7 3 2 1 SHOW ACCOUNT RECO...

Страница 12: ...acceptor set up Peripheral units set up See 7 3 2 3 3 See 7 3 2 3 2 Write your 16 digits message to appear on the display when in stand by condition See Section 7 3 2 3 1 Only if ACS reader is present...

Страница 13: ...touch changes the time value by 0 01 seconds 10 msec steps Notice holding down the key for 4 seconds the increase decrease variation runs faster Once the desired value has been reached it can be conf...

Страница 14: ...en complete the confirmation message gets displayed If a second Master key or the Service key must be created repeat the process described Or else choose the Service Key option in the menu to initiali...

Страница 15: ...wing revolving messages will be displayed should the Key be spoiled or invalid the following message will be displayed KEY NOT ENABLED Insert Key to be initialized Insert Key to be initialized DO NOT...

Страница 16: ...place so preserving secrecy NOTICE when DEFAULT CONFIGURATION is restored the PIN code gets reset to 0000 If the entered PIN is not correct the User is given another 4 tries before the board gets blo...

Страница 17: ...nal amount of time will be added up to the remaining fraction of the time already bought 8 2 Keys with sufficient credit Introducing an RFID key charged with sufficient credit or as many coins as to r...

Страница 18: ...th the prescribed safety requirements intentional or unwilled tampering wrong or careless use or maintenance non compliance with precautions prescribed see Chapter 4 Caution natural disasters vandalis...

Страница 19: ...TIMEBOX ACS ALBERICI Rev 1 05 Manual Page 19...

Страница 20: ......

Страница 21: ...1 05 Manual Page 21 NOTICE Alberici S p A reserves the right to change the features and the specifications to the equipment described at any time and without notice in the pursuit of the incessant imp...

Страница 22: ...Fax 39 051 944 594 Via Ca Bianca 421 40024 Castel San Pietro Terme BO ITALY Progettazione e produzione di sistemi di pagamento accessori per videogames e macchine vending Design and manufacture of pa...

Отзывы: