Equipment Mounting
4200-106
9-1
Revision 3
9.
Equipment Mounting
The equipment can accommodate two types of mounting:
19” rack mount or
flush mount. Standard
mounting is 19” rack mounting.
For 23” rack mounting, 1U rack reducing brackets are commercially
available and would be required.
9.1
Flush Mounting Kit (Optional)
If the flush mount option is required, optional angle brackets will need to be installed on each side of
the unit. To connect the flush mount brackets to the unit, remove the two screws on each side that
secure the rack mount brackets to the unit. Install the supplied front spacer brackets using the top
mounting hole and the flat head screws from the rack mount bracket. Remove the lower flat head screw
from the rear spacer bracket. Secure the flush mount bracket through both the bracket and bracket
spacer using the rack mounting kit-supplied pan head screws at both the front and rear locations for
each side. Flush mounted equipment footprint is shown below.
Figure 6 - Optional Flush Mount Kit Mounting