4200–063

 

R4.3

 

1

 

 

1.

 

Product Description 

The

 

BDS

40

 

is

 

a

 

stand

alone

 

monitor

 

for

 

UPS

 

applications

 

and

 

is

 

designed

 

for

 

use

 

with

 

UPS

 

battery

 

cabinets.

 

Albér

 

monitors

 

provide

 

early

 

warning

 

detection

 

of

 

battery

 

problems.

 

The

 

monitor

 

checks

 

the

 

state

 

of

 

health

 

of

 

each

 

cell

 

by

 

performing

 

a

 

proactive

 

resistance

 

test,

 

a

 

reliable

 

predictor

 

of

 

battery

 

performance.

 

In

 

addition,

 

to

 

indicate

 

immediate

 

battery

 

health

 

and

 

monitor

 

status

 

of

 

a

 

given

 

location,

 

the

 

system

 

reports

 

to

 

a

 

Central

 

computer

 

a

 

generic

 

PC

 

displaying

 

status

 

screens.

 

 

Using

 

polling

 

and

 

data

 

transfer

 

algorithms,

 

the

 

Battery

 

Monitor

 

Data

 

Manager

 

BMDM

 

software

 

program

 

with

 

a

 

PC

 

help

 

to

 

manage

 

over

 

1000

 

monitor

 

systems.

 

Data

 

is

 

stored

 

in

 

the

 

computer

 

database

 

for

 

later

 

analysis

 

and

 

reporting.

 

At

 

any

 

time,

 

service

 

personnel

 

may

 

call

 

a

 

battery

 

location

 

from

 

the

 

Central

 

computer

 

or

 

a

 

remote

 

location,

 

or

 

directly

 

connect

 

to

 

the

 

monitor

 

without

 

losing

 

contact

 

with

 

the

 

computer.

 

 

The

 

Data

 

Manager

 

string

 

and

 

monitor

 

status

 

indicators

 

make

 

central

 

battery

 

monitoring

 

easy.

 

Terms

 

such

 

as

 

Discharging,

 

Alarm

 

or

 

Warning

 

for

 

string

 

status

 

or

 

Active

 

for

 

monitor

 

status

 

quickly

 

summarize

 

events.

 

Conditions

 

reported

 

to

 

the

 

Central

 

computer

 

are

 

displayed

 

as

 

a

 

list,

 

to

 

easily

 

identify

 

trouble

 

spots.

 

The

 

system

 

also

 

features

 

several

 

methods

 

of

 

automated

 

reporting

 

of

 

alarm

 

occurrences,

 

such

 

as

 

contacting

 

key

 

personnel

 

via

 

a

 

pager,

 

email

 

or

 

fax.

 

 

Flexibility

 

was

 

a

 

major

 

design

 

consideration.

 

Because

 

the

 

monitors

 

are

 

stand

alone

 

units

 

with

 

no

 

external

 

computer

 

needed,

 

a

 

primary

 

protocol

 

using

 

Modbus

 

ASCII

 

was

 

selected

 

for

 

easy

 

incorporation

 

of

 

the

 

monitor

 

into

 

large

scale

 

facility

 

monitors.

 

This

 

allows

 

third

party

 

interfaces

 

to

 

access

 

all

 

the

 

stand

alone

 

features

 

of

 

the

 

monitor,

 

yet

 

leaves

 

the

 

advanced

 

features

 

of

 

the

 

BMDM

 

remote

 

communication

 

software

 

available

 

for

 

service

 

personnel.

 

1.1

 

Normal Operating Mode 

In

 

normal

 

mode,

 

the

 

system

 

scans

 

all

 

parameters

 

in

 

one

 

to

 

five

 

seconds,

 

depending

 

on

 

the

 

configuration.

 

As

 

readings

 

are

 

taken,

 

they

 

are

 

compared

 

to

 

user

programmed

 

alarm

 

levels.

 

The

 

monitor

 

can

 

then

 

call

 

a

 

Central

 

computer

 

and

 

energize

 

an

 

alarm

 

contact

 

if

 

a

 

parameter

 

exceeds

 

a

 

level.

 

Front

 

panel

 

LEDs

 

indicate

 

scan

 

and

 

alarm

 

status,

 

and

 

alarm

 

events

 

are

 

stored

 

in

 

memory

 

for

 

future

 

analysis.

 

The

 

BDS

 

can

 

be

 

programmed

 

for

 

critical

 

and

 

maintenance

 

alarms.

 

1.2

 

Discharge Mode 

If

 

a

 

discharge

 

is

 

detected,

 

the

 

system

 

goes

 

into

 

a

 

data

 

logging

 

mode

 

and

 

stores

 

battery

 

voltages

 

and

 

discharge

 

current

 

into

 

a

 

discharge

 

record.

 

1.3

 

Resistance Test Mode 

A

 

battery

 

resistance

 

test

 

may

 

be

 

performed

 

at

 

user

set

 

intervals.

 

The

 

test

 

is

 

similar

 

to

 

that

 

performed

 

by

 

the

 

Albér

 

Cellcorder.

 

On

 

a

 

BDS

40,

 

up

 

to

 

ten

 

intertiers

 

can

 

be

 

configured

 

for

 

this

 

measurement.

 

 

 

 

Содержание BDS-40

Страница 1: ...BDS 40 Monitor Product Description Guide Trust Your Batteries 3103 North Andrews Avenue Extension Pompano Beach FL 33064 Tel 954 623 6660 Fax 954 623 6671 www alber com 4200 063 R4 3...

Страница 2: ...sion Pompano Beach FL 33064 This guide may not be copied in whole or in part without express written permission from Alb rcorp Information in this document is subject to change without notice Microsof...

Страница 3: ...Switch 5 Base Unit Controller Connectors Rear Panel 6 Input Output TELCO Critical Alarm Maintenance Alarm Remote Reset Fiber Optics LAN and Local 6 Base Unit DCM Connectors Rear Panel 7 Input Temperat...

Страница 4: ...Outputs 19 Parameters Features 19 Measurement Range Tolerance 19 Communications 20 Data Storage 20 Control Switches 20 Dimensions 20 Agencies 20 Drawings Important Note The drawings in this manual may...

Страница 5: ...5 Figure 5 Base Unit Rear Panels 6 Figure 6 BDS 40 Base Unit Controller Rear Panel Connectors 6 Figure 7 Base Unit DCM Rear Panel Connectors 7 Figure 8 BDS 40 Base Unit DCM Controls 7 Figure 9 BDS 40...

Страница 6: ......

Страница 7: ...tem also features several methods of automated reporting of alarm occurrences such as contacting key personnel via a pager email or fax Flexibility was a major design consideration Because the monitor...

Страница 8: ...m condition Communicates with an external computer via USB RS 232 modem and LAN Network compatible 1 6 Battery Monitor Data Manager BMDM Program Features Windows 2000 XP 7 and 8 compatible Central com...

Страница 9: ...tions may appear elsewhere in this manual or in related manuals Note Drawings in this manual may be for reference only or superseded by later drawings For the latest information refer to the drawings...

Страница 10: ...ause internal temperature exceeded specifications DCM TX and RX COM Port Critical Alarm Maintenance Alarm and Resistance Test Lower DCM TX Green G Flashes during fiber optic transmit DCM RX Green G Fl...

Страница 11: ...Port on Front Panel USB LOCAL PORT USB port Connects to a laptop computer Alarm Reset Switch Figure 4 Alarm Reset Switch During normal operation clears latched alarms If held during power up clears e...

Страница 12: ...on off 2 Output Power 1 to 6 Up to six connectors providing DCM power 24VAC at 1A Configuration dependent 3 TELCO RJ 11 jack Option dependent Communicates with a remote computer via telephone 4 Criti...

Страница 13: ...ensors 3 Transducers Float Current and Discharge Current For Float Current and Discharge Current Transducers 4 Fiber Optics TX and RX Fiber optic transmit receive ports for String communication 5 J1 t...

Страница 14: ...Figure 10 BDS 40 Plus Front Panel Status Indicators Status Green G Upper Flashes during normal DCM operating conditions TX Green G Flashes during fiber optic transmit TX Green G Flashes during fiber o...

Страница 15: ...Unit Controller Rear Panel Connectors 1 Input 24VAC 50 60Hz AC Power For 24VAC power 2 Temperature 1 and 2 For Temperature Sensors 3 Transducers Float Current and Current For Float Current and Discha...

Страница 16: ...is an overview of the BDS 40 monitor configurations The BDS 40 model numbers are structured as follows Thus a typical model number might be 1003 750A CRAA21 1003 nnn XXxxxxxx required for 16V jars 100...

Страница 17: ...2 4S of 9J D_xxxxxx 1X36X12 3S of 12J E_xxxxxx 1X30X12 5S of 6J F_xxxxxx 1X30X12 10S of 3J G_xxxxxx 1X40X12 4S 12 12 8 of 8J H_xxxxxx 1X40X12 8S of 5J I_xxxxxx 1X40X12 5S of 8J J_xxxxxx 1X30X12 3J 6S...

Страница 18: ...12 of 10J U_xxxxxx 1X30X12 6S of 5J V_xxxxxx 1X20X12 4S of 2 6 6 of 6J W_xxxxxx 1X24X12 8S of 3J X_xxxxxx 1X40X12 2S of 20J Y_xxxxxx 1X40X12 2S of 15 and 1S of 10J Z_xxxxxx 1X30X12 6S of 4J and 2S of...

Страница 19: ...xxxx 1X20X12 3S of 7 6 of 7J 12xxxxxx 1X36X12 9S of 4J 13xxxxxx 1X33X12V 1S of 4J 4S of 6J 1S of 5J 14xxxxxx 1X40X12V 4S of 4J 4S of 6J 15xxxxxx 1X36X12V 4S of 8J 1S of 4J 16xxxxxx 1X36X12V 1S of 5J 2...

Страница 20: ...x 1X40X12V 3S of 12J 1S of 4J 34xxxxxx 1X38X12V 9S of 4J 1S of 4J 35xxxxxx 1X40X12V 5S of 7J 1S OF 5J 36xxxxxx 1X40X12V 1S of 24J 1S OF 16J 37xxxxxx 1X32X12V 1 of 2 Dual Battery Cabinet 38xxxxxx 1X32X...

Страница 21: ...pen Rack Configurations 70xxxxxx 1X17X12 71xxxxxx 1X18X12 72xxxxxx 1X19X12 73xxxxxx 1X20X12 74xxxxxx 1X21X12 75xxxxxx 1X22X12 76xxxxxx 1X23X12 77xxxxxx 1X24X12 78xxxxxx 1X25X12 79xxxxxx 1X26X12 80xxxx...

Страница 22: ...X16 Note If your configuration is not in this list consult your Alber Representative for the most up to date configuration list Position xxXxxxxx Discharge Current C Current Transducer N None Position...

Страница 23: ...ier resistance channels for cabinet configurations Eight interiors maximum for Open Rack Configurations 0 20 jars 4 intertiers 21 30 jars 6 intertiers 31 40 jars 8 intertiers Two temperature channels...

Страница 24: ...ar panel LAN port RJ 45 Optional rear panel RJ 11 TELCO line internal 14 4Kbs modem rear panel optional Fiber optic ports two for system communications Data Storage SRAM 8 MB nonvolatile memory for al...

Страница 25: ...l temperature and current transducers are required Outputs 15VDC 15VDC power output optional for discharge current transducer LEDs one each GREEN G DCM status GREEN G TX transmit GREEN G RX receive Re...

Страница 26: ...setting string identification Operating Environment Temperature range 5 C to 40 C 41 F to 104 F Humidity range 0 to 80 RH non condensing at 5 C to 31 C 0 to 50 RH non condensing at 32 C to 40 C Indoor...