background image

 

 

4200–063

 

R4.3

 

18

 

 

Parameters

 

/

 

Features

 

 

Number

 

of

 

cell

 

channels:

 

Up

 

to

 

six

 

strings

 

of

 

40

 

12

volt

 

jars.

 

Measurement

 

Range

 

/

 

Tolerance

 

 

Cell

 

voltage:

 

0

 

to

 

20V,

 

0.15%

 

of

 

reading

 

±4mV

 

 

Cell

 

resistance:

 

0

 

to

 

32,000µ

,

 

5%

 

of

 

reading

 

±1



 

 

String

 

voltage:

 

0

 

to

 

600.0V,

 

0.2%

 

of

 

reading

 

±0.5V

 

 

Intertier

 

resistance:

 

0

 

to

 

5m

,

 

5%

 

of

 

reading

 

5



.

 

 

Temperature:

 

0

C

 

to

 

80

C

 

(32

F

 

to

 

176

F),

 

1

C.

 

 

Discharge

 

current:

 

0

 

to

 

4000A

 

5%

 

of

 

full

 

scale

 

(using

 

CT)

 

 

Float

 

current:

 

0

 

to

 

5000mA

 

±50mA.

 

*Optional

 

current

 

transducer

 

required.

  

*Transducer

 

accuracy

 

affects

 

overall

 

current

 

reading

 

accuracy.

 

Communication

 

 

Protocol:

 

MODBUS,

 

and

 

SNMP.

 

 

Local

 

port,

 

USB

 

connector–front

 

panel

 

 

Local

 

port,

 

RS–232

 

DB–9

 

connector

 

–rear

 

panel

 

 

LAN

 

port,

 

RJ–45–Optional;

 

rear

 

panel

 

 

RJ–11

 

TELCO

 

line,

 

internal

 

14.4Kbs

 

modem–rear

 

panel

 

(optional)

 

 

Fiber

 

optic

 

ports:

 

two

 

for

 

system

 

communications

 

Data

 

Storage

 

 

SRAM

 

(8

 

MB)

 

nonvolatile

 

memory

 

for

 

all

 

configuration

 

settings

 

and

 

data

 

 

Flash

 

memory

 

for

 

firmware

 

upgrades

 

Control

 

Switches

 

 

Power

 

on/off:

 

Main

 

DCM

 

power

 

switch

 

on

 

rear

 

panel

 

of

 

BDS

 

Controller

 

module.

  

Rocker

 

switch.

 

 

Alarm

 

Reset

 

switch

 

on

 

front

 

panel

 

of

 

BDS

 

Controller

 

module.

  

Momentary

 

push

 

button.

 

 

DCM

 

and

 

String

 

ID:

 

DIP

 

switch

 

on

 

rear

 

panel

 

for

 

setting

 

string

 

identification.

 

Operating

 

Environment

 

 

Temperature

 

range:

 

5

C

 

to

 

40

C

 

(41

F

 

to

 

104

F).

 

 

Humidity

 

range:

   

0%

 

to

 

80%

 

RH

 

(non

 

condensing)

 

at

 

5

C

 

to

 

31

C.

 

 

   

0%

 

to

 

50%

 

RH

 

(non

 

condensing)

 

at

 

32

C

 

to

 

40

C.

 

 

Indoor

 

use

 

only.

 

 

Installation

 

category

 

II.

 

 

Pollution

 

degree

 

2.

 

 

Altitude

 

0

 

to

 

2000

 

meters

 

above

 

sea

 

level.

 

Dimensions

 

 

19"W

 

x

 

16.2"D

 

x

 

7.8"H

 

 

34

 

lbs.

 

Содержание BDS-40

Страница 1: ...BDS 40 Monitor Product Description Guide Trust Your Batteries 3103 North Andrews Avenue Extension Pompano Beach FL 33064 Tel 954 623 6660 Fax 954 623 6671 www alber com 4200 063 R4 3...

Страница 2: ...sion Pompano Beach FL 33064 This guide may not be copied in whole or in part without express written permission from Alb rcorp Information in this document is subject to change without notice Microsof...

Страница 3: ...Switch 5 Base Unit Controller Connectors Rear Panel 6 Input Output TELCO Critical Alarm Maintenance Alarm Remote Reset Fiber Optics LAN and Local 6 Base Unit DCM Connectors Rear Panel 7 Input Temperat...

Страница 4: ...Outputs 19 Parameters Features 19 Measurement Range Tolerance 19 Communications 20 Data Storage 20 Control Switches 20 Dimensions 20 Agencies 20 Drawings Important Note The drawings in this manual may...

Страница 5: ...5 Figure 5 Base Unit Rear Panels 6 Figure 6 BDS 40 Base Unit Controller Rear Panel Connectors 6 Figure 7 Base Unit DCM Rear Panel Connectors 7 Figure 8 BDS 40 Base Unit DCM Controls 7 Figure 9 BDS 40...

Страница 6: ......

Страница 7: ...tem also features several methods of automated reporting of alarm occurrences such as contacting key personnel via a pager email or fax Flexibility was a major design consideration Because the monitor...

Страница 8: ...m condition Communicates with an external computer via USB RS 232 modem and LAN Network compatible 1 6 Battery Monitor Data Manager BMDM Program Features Windows 2000 XP 7 and 8 compatible Central com...

Страница 9: ...tions may appear elsewhere in this manual or in related manuals Note Drawings in this manual may be for reference only or superseded by later drawings For the latest information refer to the drawings...

Страница 10: ...ause internal temperature exceeded specifications DCM TX and RX COM Port Critical Alarm Maintenance Alarm and Resistance Test Lower DCM TX Green G Flashes during fiber optic transmit DCM RX Green G Fl...

Страница 11: ...Port on Front Panel USB LOCAL PORT USB port Connects to a laptop computer Alarm Reset Switch Figure 4 Alarm Reset Switch During normal operation clears latched alarms If held during power up clears e...

Страница 12: ...on off 2 Output Power 1 to 6 Up to six connectors providing DCM power 24VAC at 1A Configuration dependent 3 TELCO RJ 11 jack Option dependent Communicates with a remote computer via telephone 4 Criti...

Страница 13: ...ensors 3 Transducers Float Current and Discharge Current For Float Current and Discharge Current Transducers 4 Fiber Optics TX and RX Fiber optic transmit receive ports for String communication 5 J1 t...

Страница 14: ...Figure 10 BDS 40 Plus Front Panel Status Indicators Status Green G Upper Flashes during normal DCM operating conditions TX Green G Flashes during fiber optic transmit TX Green G Flashes during fiber o...

Страница 15: ...Unit Controller Rear Panel Connectors 1 Input 24VAC 50 60Hz AC Power For 24VAC power 2 Temperature 1 and 2 For Temperature Sensors 3 Transducers Float Current and Current For Float Current and Discha...

Страница 16: ...is an overview of the BDS 40 monitor configurations The BDS 40 model numbers are structured as follows Thus a typical model number might be 1003 750A CRAA21 1003 nnn XXxxxxxx required for 16V jars 100...

Страница 17: ...2 4S of 9J D_xxxxxx 1X36X12 3S of 12J E_xxxxxx 1X30X12 5S of 6J F_xxxxxx 1X30X12 10S of 3J G_xxxxxx 1X40X12 4S 12 12 8 of 8J H_xxxxxx 1X40X12 8S of 5J I_xxxxxx 1X40X12 5S of 8J J_xxxxxx 1X30X12 3J 6S...

Страница 18: ...12 of 10J U_xxxxxx 1X30X12 6S of 5J V_xxxxxx 1X20X12 4S of 2 6 6 of 6J W_xxxxxx 1X24X12 8S of 3J X_xxxxxx 1X40X12 2S of 20J Y_xxxxxx 1X40X12 2S of 15 and 1S of 10J Z_xxxxxx 1X30X12 6S of 4J and 2S of...

Страница 19: ...xxxx 1X20X12 3S of 7 6 of 7J 12xxxxxx 1X36X12 9S of 4J 13xxxxxx 1X33X12V 1S of 4J 4S of 6J 1S of 5J 14xxxxxx 1X40X12V 4S of 4J 4S of 6J 15xxxxxx 1X36X12V 4S of 8J 1S of 4J 16xxxxxx 1X36X12V 1S of 5J 2...

Страница 20: ...x 1X40X12V 3S of 12J 1S of 4J 34xxxxxx 1X38X12V 9S of 4J 1S of 4J 35xxxxxx 1X40X12V 5S of 7J 1S OF 5J 36xxxxxx 1X40X12V 1S of 24J 1S OF 16J 37xxxxxx 1X32X12V 1 of 2 Dual Battery Cabinet 38xxxxxx 1X32X...

Страница 21: ...pen Rack Configurations 70xxxxxx 1X17X12 71xxxxxx 1X18X12 72xxxxxx 1X19X12 73xxxxxx 1X20X12 74xxxxxx 1X21X12 75xxxxxx 1X22X12 76xxxxxx 1X23X12 77xxxxxx 1X24X12 78xxxxxx 1X25X12 79xxxxxx 1X26X12 80xxxx...

Страница 22: ...X16 Note If your configuration is not in this list consult your Alber Representative for the most up to date configuration list Position xxXxxxxx Discharge Current C Current Transducer N None Position...

Страница 23: ...ier resistance channels for cabinet configurations Eight interiors maximum for Open Rack Configurations 0 20 jars 4 intertiers 21 30 jars 6 intertiers 31 40 jars 8 intertiers Two temperature channels...

Страница 24: ...ar panel LAN port RJ 45 Optional rear panel RJ 11 TELCO line internal 14 4Kbs modem rear panel optional Fiber optic ports two for system communications Data Storage SRAM 8 MB nonvolatile memory for al...

Страница 25: ...l temperature and current transducers are required Outputs 15VDC 15VDC power output optional for discharge current transducer LEDs one each GREEN G DCM status GREEN G TX transmit GREEN G RX receive Re...

Страница 26: ...setting string identification Operating Environment Temperature range 5 C to 40 C 41 F to 104 F Humidity range 0 to 80 RH non condensing at 5 C to 31 C 0 to 50 RH non condensing at 32 C to 40 C Indoor...