Version 2.0
Manual #6410T0021
12
Albany High Speed Doors
Installation & Operation
MOUNTING THE DEFROST SYSTEM (continued…)
The blower assembly is heavy. Use proper lifting devices and tech-
niques to securely and safely lift the assembly. Failure to properly
secure the head assembly could result in death or serious injury.
ASSEMBLING IR HEAT LAMPS
If the door was ordered with IR Lamps for the optional UltraDefrost system, the following steps must be taken at
this point in the installation process:
1. Remove the end cover plates from the lamp fixture
2. Carefully unpack the IR lamp bulbs and red sleeves one at a time.
3. Slide a red sleeve over each bulb and install into each fixture.
4. Connect the wire on the ends of the lamp to the screw terminal
located at each end of the fixture. Leave a 1/4” loop between
the wire on the end of the lamp and the screw terminal.
5. Cut off any excess wire leading away from each screw terminal
once the lamp bulb is wired in place.
Never touch the glass surface of the lamp bulb or the red sleeve with
bare fingers or handle them with a dirty or oily rag. Any debris or oil on
the surface of the lamp will lead to a “hot spot” which could cause the
lamp to immediately fail.
If the 1/4” loops are not made,
the bulb can become damaged
as it expands upon heating.
The defrost system components must be aligned for proper
function. Follow the list of guidelines below and adjust as nec-
essary for the application if frost is present.
Direct IR Lamps at the top edge of the bottom bar
Loosen the pivot bolt at each end of the fixture
Aim the lamp fixture to the desired angle
Tighten the pivot bolts
Direct Blowers at top 1/2 to 3/4 of door opening height
Loosen the pivot bolt and adjusting bolt at each end of
the blower
Aim the blower unit to the desired angle
Tighten all bolts
ALIGNING THE DEFROST COMPONENTS
A
IM
I
R
L
A
M
PS
A
T
TOP
O
F
B
OTTO
M
B
A
R
A
IM
B
L
OWER
S
A
T
TOP
1
/2
TO
3
/4
OF
PA
NEL
Improper direction of the heat lamps towards the upper areas of the
panel in near proximity to the lamp could cause the panel to overheat
and become damaged.
Содержание RapidRoll 355
Страница 14: ...13 Manual 6410T0021 1 5 2011 ...
Страница 15: ...Version 2 0 Manual 6410T0021 14 Albany High Speed Doors Installation Operation ...
Страница 16: ...15 Manual 6410T0021 1 5 2011 ...
Страница 17: ...Version 2 0 Manual 6410T0021 16 Albany High Speed Doors Installation Operation ...
Страница 18: ...17 Manual 6410T0021 1 5 2011 ...
Страница 19: ...Version 2 0 Manual 6410T0021 18 Albany High Speed Doors Installation Operation ...