background image

INSTALLATION AND OPERATING INSTRUCTIONS

 

Solenoid Dropbolt

  YD25K

 

Содержание YD25K

Страница 1: ...INSTALLATION AND OPERATING INSTRUCTIONS Solenoid Dropbolt YD25K...

Страница 2: ...oduct is carrying the CE Mark in accordance with the related European Directives Responsible for CE Marking is BQT Solutions SEA Pte Limited 41B Neil Road 03 01 Singapore 088824 The complete EU Declar...

Страница 3: ...INSTALLATION ASSESSMENT 5 4 1 MECHANICAL 5 4 2 ELECTRICAL 6 5 INSTALLATION 6 5 1 MORTISE INSTALLATION 6 5 1 SURFACE INSTALLATION 8 6 WIRING 10 6 1 THREE WIRE CONNECTION 10 6 2 TWO WIRE CONNECTION FAI...

Страница 4: ...ng unlocking attempts Adjustable timed re lock Current reduction circuitry Door position and bolt position monitors High physical strength 10 000N 2 PRODUCT UNBOXED The YD25K is supplied with four 10G...

Страница 5: ...the YD25K will be mortised or surface mounted to the door door frame Mortise installation ensures a discrete solution as the lock and strike plate can be embedded into the door and frame however in s...

Страница 6: ...these connections to integrate into access control or alarm systems to provide full monitoring Finally the correct gauge of wire needs to be chosen as when connecting the power wires and to the lock v...

Страница 7: ...ebris and deep enough to allow the lock pin to fully extend when locked 5 1 2 Wiring the lock Wires are run out from the back of the mortise and following the connection guide on the locks cover conne...

Страница 8: ...e The housing has two holes that accept the stepped washers from the inside and once the housing is in place the screws can be tightened with a 2 Phillips head screwdriver through the outside holes On...

Страница 9: ...ousings are supplied with self adhesive tape With the backing removed the housing can be applied directly to the glass A flat stainless steel dress plate is fitted on the opposite of the glass to give...

Страница 10: ...ected to terminals 1 and 3 Wire links not supplied are connected from terminals 2 to 11 and 1 to 9 for fail safe Additionally manual override of the lock is achieved by utilising the key cylinder elec...

Страница 11: ...1 Fail safe operation Assume the door is closed and locked Momentarily connecting 1 and 2 unlocks the door for a period of 9 seconds After the 9 seconds has elapsed if the door has not been opened the...

Страница 12: ...A dry cloth can be used to polish the stainless steel face plate and strike plate as required This lock contains components that are subject to wear based on usage doorway operation and installation...

Отзывы: