NetworX CDMA Module

 

|

 

Installation Guide 

 

Radio Status LEDs                                                                  

There are five small radio status LEDs, located on the bottom of the module 
(see 

Figure 1

). T

able 4

 below describes the LED functions. 

 
Table 4: LED Functions 

LED 

Function 

L1 

Error LED. Flashes 1 to 8 times in an 8-second interval to indicate 
specific error. See 

Table 5

 for errors and common fixes. 

L2 

Panel Communication and Z-Wave status messages. Flashes every 
time the module communicates with the panel and flashes in 
patterns to indicate Z-Wave status. 

L3 

CDMA Communication. Flashes every time the CDMA signal level is 
checked and when packets are exchanged with Alarm.com. 

L4 

CDMA Signal Level. Flashes 0 to 5 times to indicate signal strength, or 
toggles on/off slowly when communicating with Alarm.com servers. 

L5 

Z-Wave Error LED. See 

Table 6 

for error descriptions. 

 
LED Details 

LED L1 (red) 

L1 flashes when there is an error. The number of flashes indicates the error 
number. If there are two or more errors at the same time, the errors will 
flash one after the other. The LED will stay off for at least four seconds 
between errors. 

Table 5: Errors flashed on L1 (red)

 

Number of 
flashes 

Error and solution 

Module cannot communicate with the panel.  Perform a power 
cycle on the panel. If the error persists lift the module out of 
the panel and re-insert it. If the error is still observed try a 
different module. Finally, if that does not fix the problem try a 
different panel. 

2 then 4 

The module provisioning process could not be completed. 

2 then 5 

The module provisioning process could not be completed 
because the module is currently roaming on the carrier’s 
network. 

The module is trying to register on the CDMA network. If it 
persists for more than a few minutes, the module is having 
problems registering with the CDMA network. Check L4 for 
signal level. If signal level is lower than 2 “bars”, change the 
panel’s location or use a remote antenna option. If the signal is 
good, the module may be roaming on a CDMA network that 
does not partner with our CDMA providers. 

The module is registered on the CDMA network but cannot 
connect with Alarm.com. Contact Alarm.com Technical 
Support. 

Radio portion of the module is not working correctly. If this 
persists for more than a few minutes the module may need to 
be replaced.  This error is extremely rare so verify that the 
module is flashing 5 times.   

This is an error only if it persists for more than a minute. 
Otherwise, it’s just an indication that the module is fixing an 
unusual condition regarding communication with the CDMA 
network. 

There are bit sets in Location 21 that prevent Alarm.com from 
getting the sensor list from the panel. In Location  21, segment 
1, if bits 5 and 6 are set the module can not retrieve the sensor 
list. Note that bit 7 will prevent location 21 from being 
displayed at the keypad. Bits 5, 6 and 7 can only be set via the 
Downloader program.  

This could also mean that the module is not compatible with 
the current panel type. 

If it persists, the account may have been set up incorrectly.  
Contact Alarm.com Technical Support. You will be asked to 
check the serial number of the module. 

LED L2 (yellow) 

L2 flashes with every communication between the module and the panel. 
Normal pattern calls for a series of quick flashes every two seconds in Idle  
Mode or four seconds in PowerSave Mode. It also occasionally flashes in 
patterns to indicate Z-Wave status. See 

Table 6

 for a description of various 

possibilities. 

Table 6: Z-wave LED status indicators 

LED 2 

LED 5 

Device status or error 

Description 

4-blink 

 

Add Mode (lasts 120 
seconds or until a device 
is added) 

In this mode you can add a 
device to the local Z-Wave 
network. Devices cannot be 
added to a network if they 
are already a part of a 
network 

2-blink 

 

Delete Mode (lasts 120 
seconds or until a device 
is deleted) 

In this mode you can delete a 
device from a Z-Wave 
network. A device can only 
be in one network at a time, 
and must receive a “delete” 
command before it can be 
learned into a new network 

Solid 

 

Successful add 
node/remove 
node/replication (lasts 
60 seconds) 

After receiving this signal 
leave all devices by the 
CDMA module for 1 minute. 
Locks must be left next to the 
module for 4 minutes 

Solid 
with 
one 
blink 

 

Add node attempt failed 
because node already in 
network (lasts 60 
seconds) 

Device you attempted to add 
to a network is already in a 
network, and must be 
“deleted” before it can join a 
new network 

 

2-blink 

No other nodes are in 
the network (lasts until a 
device is added to the 
network) 

No devices have been added 
that can be controlled by the 
CDMA module yet. See 
above for instructions on 
how to add devices 

 

5-blink 

Learn mode error (lasts 
60 seconds) 

The device was not 
successfully added to the Z-
Wave network. 

 

6-blink 

No Home ID present 
(lasts until the module 
connects to Alarm.com 
and is configured) 

When the CDMA module first 
connects to Alarm.com it is 
configured with a necessary 
unique network ID 

LED L3 (yellow) 

L3 flashes with every communication between the module and its radio unit 
in Idle Mode, and with every communication with Alarm.com in Connected 
Mode. In PowerSave Mode, this LED flashes in unison with LED 2. 

 

Содержание NX-208E

Страница 1: ...ific error See Table 5 for errors and common fixes L2 Panel Communication and Z Wave status messages Flashes every time the module communicates with the panel and flashes in patterns to indicate Z Wave status L3 CDMA Communication Flashes every time the CDMA signal level is checked and when packets are exchanged with Alarm com L4 CDMA Signal Level Flashes 0 to 5 times to indicate signal strength o...

Страница 2: ... module to communicate successfully 3 Verify that radio status LED 1 is not flashing any errors see Radio Status LEDs on page 3 Also verify that LED 4 is flashing a signal level of two or higher Otherwise relocate the module If LED 1 and LED 4 are not flashing and LED 2 and LED 3 are flashing together the module is in PowerSave mode and the battery needs to be charged 4 Perform a manual phone test...

Страница 3: ...n indication that the module is fixing an unusual condition regarding communication with the CDMA network 7 There are bit sets in Location 21 that prevent Alarm com from getting the sensor list from the panel In Location 21 segment 1 if bits 5 and 6 are set the module can not retrieve the sensor list Note that bit 7 will prevent location 21 from being displayed at the keypad Bits 5 6 and 7 can onl...

Страница 4: ...Name Programming Mode Then enter 192 for the module serial number or 190 for the reports list By default the keypad shows Zone 190 or Zone 192 To tell the CDMA module to show its information in place of these zone names add a space in front of the zone names by pressing the Stay button followed by star button and pound button to validate the entry When you are done with all 3 zones press Exit to l...

Страница 5: ...ferred login name for the customer Alarm com Module Serial Number At the end of the account creation process you will be able to print a Welcome Letter for the customer that has their login information and temporary password for the Alarm com website FCC Compliance Changes or modifications not expressly approved by Alarm com can void the user s authority to operate the equipment This equipment has...

Отзывы: