Sounder -

 A local warning device at the keypad to alert that (a) entry delay has started; (b) an

attempt was made to arm with a zone in trouble; (c) a Chime Zone or Day Zone was activated;
(d) a fire alarm or fire trouble condition exists; or (e) the central station has acknowledged
arming (optional).

Trouble - 

An 

open door, window, or other problem that may prevent arming.

User Program Code -

 A code (up to 

digits) required to enter the Program Mode in order to

program or change Arm/Disarm Codes.

 

Watch Mode (option) -

 Turns all Day Zones on and off simultaneously by pressing Key [B]

twice. (Also  see 

Group Bypass Zones, 

below.)

Zones - Independent circuits that protect specific areas of the premises:

Auto-Bypass Zone: A zone that will be automatically bypassed from the protection system if it

is in trouble (faulty) when the system is armed.

Burglary Zone: Detects intrusion.

Day Zone: A zone programmed to cause visual and audible indication at the keypad when it is in

trouble while disarmed. This feature is generally used to detect a problem, such as a break in a

window foil, during the day. If a Day Zone is open, the green READY light will flash, the
sounder will pulse, and the numerical display will indicate the zone. Hold down Key  [9] to

silence the sounder and clear the display. Arm and disarm the panel to re-enable the Day Zone.

(This feature may have been programmed so that Key [9] will turn off only the sounder; the

display will continue to indicate the open zone until the zone is corrected, at which time the
display will be cleared and the Day Zone re-enabled.)

Exit/Entry Follower Zone: Provides exit and entry delay for interior devices. Entry delay only

occurs if re-entry takes place through the normal exit/entry door.

Group Bypass Zones: Circuits within the premises, usually including space-protection devices,

interior doors, etc. (but not exterior doors or win dows) that can all be bypassed simultaneously
by pressing Key [B] twice. This feature may have been programmed to include the Chime Mode
and/or Watch Mode (optional).

Never-Armed Zone: A zone that will remain disarmed, even when the rest of the system is

armed. When tripped, it will display at the keypad when Display Status (Hold-Down Function
3) is selected. If Chime is programmed, the keypad will sound while armed or disarmed. This
feature may be used as a driveway monitor, pool alert, etc.

Priority Zone: A zone that prevents arming if in trouble.

Selective-Bypass Zone: A zone that can be individually bypassed using Key [B].

24-Hour Zone: A zone that is armed and ready at all times to respond to an emergency situation.

Содержание Eagle 8000 Series

Страница 1: ... system with many available features Your alarm specialist will explain your system and show you how it works Contact him should ques tions concerning operation arise This booklet contains important information about the operation of your system Read it careful ly and keep it handy for future reference Check the Glossary for an explanation of terms that may be unfamiliar to you n c ALARM LOCK 1990...

Страница 2: ...any security systems will ever need them all Your alarm professional has chosen appropriate features for your situation Ask him about them Your system has been carefully designed and engineered to the highest industry standards To assure optimum safety and security familiarize yourself with this equipment and periodically check its condition and state of readiness TABLE OF CONTENTS GLOSSARY 3 KEYP...

Страница 3: ...ed to display when activated option Closing A report sent to the central station when the premises is closed system armed optional Communicator Reports intrusions and emergencies directly to the central station over telephone lines Control Panel The brain of the system it controls all system functions Disarm To turn the system off by entering a User Code at the keypad Exit Entry Delay A programmed...

Страница 4: ...icate the zone Hold down Key 9 to silence the sounder and clear the display Arm and disarm the panel to re enable the Day Zone This feature may have been programmed so that Key 9 will turn off only the sounder the display will continue to indicate the open zone until the zone is corrected at which time the display will be cleared and the Day Zone re enabled l Exit Entry Follower Zone Provides exit...

Страница 5: ... ZONES OPEN ALARM LOCK SYSTEMS J _ Steady system disarmed all non 24 Hour Zones OK 0 Pulses once every second trouble on any non 24 Hour Zone l Flashes fast trouble on Day Zone BYPASS Yellow Light Steady one or more zones manually bypassed shunted Dealer programmable to display Auto Bypassed Zones and bypassed Priority Zones as well AUX FIRE TROUBLE Bottom Red Light Steady Aux Fire Zone in alarm c...

Страница 6: ...s will enable a feature that sounds a chime beep at the keypad each time a programmed zone is opened This feature may have been programmed to display the zone number as well until the zone is closed The Chime Mode functions when the alarm system is disarmed off but it will always operate on a Never Armed Zone see GLOSSARY To disable the chime feature hold down Key 5 again until sounder beeps Also ...

Страница 7: ...git codes that will allow you to arm and disarm your system Any of these codes can easily be changed or removed should it become necessary in the future to deny a user access to the premises Your security system cannot be disarmed by unauthorized persons It will respond only when a code of your choosing is entered through the keypad Service Code Your alarm specialist may have programmed User 5 s c...

Страница 8: ...Leave Check the green READY light on the keypad If it is on enter your code The red ARMED light will come on and the green light will go off If your system was programmed for an automatic audible test on arming the alarm will sound briefly shortly after arming Leave immediately through the exit entry door before your exit delay time runs out If you wait too long the keypad sounder will warn that t...

Страница 9: ... 9 remember to test your system Zones selected for Priority with Bypass may be bypassed by holding down Reset Key 9 before arming Be sure to have all zones in trouble fixed quickly TURNING OFF THE ALARM DISARMING WHEN RETURNING Disarming When You Return When you enter through the exit entry door the sounder will come on for the entire entry period If upon entering the red ARMED light is flashing l...

Страница 10: ...ne or more zones Enter your code to arm remaining zones the green light will go off and the red ARMED light will come on The yellow light will go off the next time you disarm indicating that the bypassed zones are no longer bypassed The BYPASS light does not come on when zones are auto bypassed unless programmed otherwise by your alarm specialist NOTE The Chime Mode may have been programmed to be ...

Страница 11: ... armed and disarmed all within the delay period Opening and Closing Reporting Notifies the central station every time the system is disarmed and armed Up to 4 different users can each be identified Telephone Line Test To check your telephone connection with the central station hold down Key 6 After the beep sounds a pulse tone will be heard from the keypad sounder If the phone line is good the sou...

Страница 12: ... trouble is repaired press Key 9 again to turn off the light Resetting After An Alarm The fire alarm may be reset by arming and then disarming or if so programmed by waiting for it to automatically shut off The sounder and the AUX FIRE TROUBLE light will stay on Press Key 9 to silence the sounder The red AUX FIRE TROUBLE light should go off in about 30 seconds If smoke has not cleared from a smoke...

Отзывы: