PROTECTING YOURSELF WHILE ON THE PREMISES

Arming With Zones Bypassed

 

Your alarm specialist may have programmed one or more zones for Selective Bypass, that is,
removable from the system. Since a bypassed zone cannot cause an alarm, you may wish to use
this feature to turn off the interior areas while arming, and keep your perimeter zones (windows,

doors, etc.) active.

To arm, check the green light to be sure that no zone is in trouble. Press the bypass button (Key

[B]), and then the number of the zone (1 through 8) you wish to bypass. To verify which zones

have been bypassed, hold down Key [2] until all zones have been displayed.

Bypassing Interior Zones

Your alarm specialist may have also selected all interior zones to be Group Bypass Zones.

Bypass these zones all at the same time by simply pressing Key [B] 

twice. 

The yellow BYPASS

light will come on whenever you bypass one or more zones. Enter your code to arm remaining

zones; the green light will go off and the red ARMED light will come on. The yellow light will
go off the next time you disarm, indicating that the bypassed zones are no longer bypassed. (The

BYPASS light does not come on when zones are auto-bypassed (unless programmed otherwise

by your alarm specialist.)

NOTE: The Chime Mode may have been programmed to be enabled when group bypassing

interior zones so that perimeter Chime Zones will automatically sound at the keypad when
activated. Similarly, the Watch Mode (see 

GLOSSARY) 

may be enabled by group bypassing.

Arming With Instant Protection

 

Holding down Key [4] (until beep sounds) will cancel the entry delay on the exit/entry zones  

when arming. The red ARMED light will flash

rapidly to indicate this condition. If someone

enters through an Exit/Entry Zone, an alarm will
sound immediately.

Panic Zone

To activate the Panic Zone, press Keys [*] and

[#] at the same time. The Panic Zone can be

programmed to send a silent alarm to a central

station, activate an audible alarm, or both.

10

Содержание Eagle 8000 Series

Страница 1: ... system with many available features Your alarm specialist will explain your system and show you how it works Contact him should ques tions concerning operation arise This booklet contains important information about the operation of your system Read it careful ly and keep it handy for future reference Check the Glossary for an explanation of terms that may be unfamiliar to you n c ALARM LOCK 1990...

Страница 2: ...any security systems will ever need them all Your alarm professional has chosen appropriate features for your situation Ask him about them Your system has been carefully designed and engineered to the highest industry standards To assure optimum safety and security familiarize yourself with this equipment and periodically check its condition and state of readiness TABLE OF CONTENTS GLOSSARY 3 KEYP...

Страница 3: ...ed to display when activated option Closing A report sent to the central station when the premises is closed system armed optional Communicator Reports intrusions and emergencies directly to the central station over telephone lines Control Panel The brain of the system it controls all system functions Disarm To turn the system off by entering a User Code at the keypad Exit Entry Delay A programmed...

Страница 4: ...icate the zone Hold down Key 9 to silence the sounder and clear the display Arm and disarm the panel to re enable the Day Zone This feature may have been programmed so that Key 9 will turn off only the sounder the display will continue to indicate the open zone until the zone is corrected at which time the display will be cleared and the Day Zone re enabled l Exit Entry Follower Zone Provides exit...

Страница 5: ... ZONES OPEN ALARM LOCK SYSTEMS J _ Steady system disarmed all non 24 Hour Zones OK 0 Pulses once every second trouble on any non 24 Hour Zone l Flashes fast trouble on Day Zone BYPASS Yellow Light Steady one or more zones manually bypassed shunted Dealer programmable to display Auto Bypassed Zones and bypassed Priority Zones as well AUX FIRE TROUBLE Bottom Red Light Steady Aux Fire Zone in alarm c...

Страница 6: ...s will enable a feature that sounds a chime beep at the keypad each time a programmed zone is opened This feature may have been programmed to display the zone number as well until the zone is closed The Chime Mode functions when the alarm system is disarmed off but it will always operate on a Never Armed Zone see GLOSSARY To disable the chime feature hold down Key 5 again until sounder beeps Also ...

Страница 7: ...git codes that will allow you to arm and disarm your system Any of these codes can easily be changed or removed should it become necessary in the future to deny a user access to the premises Your security system cannot be disarmed by unauthorized persons It will respond only when a code of your choosing is entered through the keypad Service Code Your alarm specialist may have programmed User 5 s c...

Страница 8: ...Leave Check the green READY light on the keypad If it is on enter your code The red ARMED light will come on and the green light will go off If your system was programmed for an automatic audible test on arming the alarm will sound briefly shortly after arming Leave immediately through the exit entry door before your exit delay time runs out If you wait too long the keypad sounder will warn that t...

Страница 9: ... 9 remember to test your system Zones selected for Priority with Bypass may be bypassed by holding down Reset Key 9 before arming Be sure to have all zones in trouble fixed quickly TURNING OFF THE ALARM DISARMING WHEN RETURNING Disarming When You Return When you enter through the exit entry door the sounder will come on for the entire entry period If upon entering the red ARMED light is flashing l...

Страница 10: ...ne or more zones Enter your code to arm remaining zones the green light will go off and the red ARMED light will come on The yellow light will go off the next time you disarm indicating that the bypassed zones are no longer bypassed The BYPASS light does not come on when zones are auto bypassed unless programmed otherwise by your alarm specialist NOTE The Chime Mode may have been programmed to be ...

Страница 11: ... armed and disarmed all within the delay period Opening and Closing Reporting Notifies the central station every time the system is disarmed and armed Up to 4 different users can each be identified Telephone Line Test To check your telephone connection with the central station hold down Key 6 After the beep sounds a pulse tone will be heard from the keypad sounder If the phone line is good the sou...

Страница 12: ... trouble is repaired press Key 9 again to turn off the light Resetting After An Alarm The fire alarm may be reset by arming and then disarming or if so programmed by waiting for it to automatically shut off The sounder and the AUX FIRE TROUBLE light will stay on Press Key 9 to silence the sounder The red AUX FIRE TROUBLE light should go off in about 30 seconds If smoke has not cleared from a smoke...

Отзывы: