The following information is applicable only where local ordinance permits use of your alarm
control panel for fire detection.
Controlling Your Fire Circuit
If your alarm specialist installed smoke detectors or heat sensing thermostats, you have 24-hour
fire protection. Your control panel will constantly monitor this zone for any alarm or trouble
condition.
Fire-Zone Alarm
An alarm on the Fire Zone will cause the bottom red light to come on and the sounder to pulse.
The fire alarm will sound, overriding any other alarm.
Fire-Zone Trouble
If there is trouble on the fire circuit, the bottom red AUX / FIRE /TROUBLE light will flash
and the sounder will pulse after a l0-second delay. To silence the sounder, press Key [9]. The
light will continue to flash to indicate the trouble. After the trouble is repaired, press Key [9]
again to turn off the light.
Resetting After An Alarm
The fire alarm may be reset by arming, and then disarming; or (if so programmed) by waiting for
it to automatically shut off. The sounder and the AUX / FIRE / TROUBLE light will stay on.
Press Key [9] to silence the sounder. The red AUX / FIRE / TROUBLE light should go off in
about 30 seconds. If smoke has not cleared from a smoke detector, or a thermostat has not
cooled, the red AUX / FIRE / TROUBLE light will remain on. Press Key [9] every 30 seconds
until the condition has cleared and the light goes off.
NOTE:
If the sounder is on due to a fire or fire-trouble condition, you will not be able to arm the
burglar alarm until you silence the sounder by holding down Key [9] until the beep sounds.