23
;
6
7
;
[ _ _ ]
:
(Event Number)
67. Add System Features
SYSTEM FEATURES
68. Delete All Relay Features added by Function 67.
;
6
8
;
0
0
0
:
•
Relay Features
(12-23. Reserved)
Use Function 67 to program
one or more
lock events and the Relay will energize when the programmed event(s) listed below oc-
curs. For example, program
;
6
7
;
3
:
and when an attempted entry fails (such as a User who enters an
incorrect or un-programmed User Code), the Relay will energize for 2 seconds.
Note:
For more information about the
Remote In-
put
, see page 10 (Wiring, Remote Input) and page 22 (Function 65).
1.
Remote Input switch closed and Function 65
Remote Input
enabled.
Because the Remote Input is enabled by factory default, the Relay will
energize when the Remote Input switch is closed.
9.
Lock Out.
Relay energizes for 2 seconds when a Lock Out occurs (i.e.
number of attempts is exceeded, see Function 60).
2.
Remote Input switch closed and Function 64
Remote Input
dis-
abled.
If the Remote Input is disabled with Function 64, the Relay will
energize when the Remote Input Switch is closed.
10.
Ambush.
Relay energizes for 2 seconds when Ambush is tripped. See
Function 66, page 22.
3.
Failed attempted entry.
Relay energizes for 2 seconds when an at-
tempted User Code entry fails.
11.
First Key Press.
Relay energizes for 2 seconds at the first key press of
any sequence.
4.
Disabled User or Group.
Relay energizes for 2 seconds when a dis-
abled User or disabled Group member enters a User Code.
5.
Follow Access Granted.
When a valid User Code is entered into the
keypad and the lock unlocks, the Relay energizes for 2 seconds. Com-
pare with Event 31.
6.
Group 1 User Code.
Relay energizes for 2 seconds when a scheduled
Group 1 User Code is entered. See Function 90, page 26.
7.
Scheduled Lock Event.
Relay energizes for 2 seconds when lock is
locked by a Schedule.
8.
Scheduled Unlock Event.
Relay energizes for 2 seconds when lock is
unlocked by a schedule
31.
Follow Access Granted--No Time Limit.**
When a valid User Code is
entered into the keypad and the lock unlocks, the Relay energizes for
the
same amount of time as the programmed Pass Time
. (The Pass
Time is the length of time the lock stays unlocked after a valid
User Code is entered. See functions 52-54). Use this feature for
remote monitoring or other activation as this feature works independ-
ently of all other relay options. Programming this feature will supersede
all other programmed relay features. Subsequent relay feature pro-
gramming will not take effect while this feature is active. Before pro-
gramming any other relay features, press
;
6
8
;
0
0
0
:
to delete this feature.
4
•
System Options
24. One Time Access for Group 3 Users***
25. Disable Sounder
26. 5 sec. Delayed Entry *
27. 15 sec. Delayed Entry *
28. 45 sec. Delayed Entry *
•
Remote Input Functions
29.
Toggle Passage Mode.
Remote Input toggles Passage Mode.
30.
Forced Unlock Follows Remote Input.
** When Remote Input switch
is closed, regardless of the current state of the lock, the lock unlocks for
the duration of the Remote Input switch closure.
32.
Remote Input Disables Unit.
**
Regardless of the current state, that
state will remain unchanged (and keypad will be disabled) for the dura-
tion of Remote Input switch closure.
34.
Forced Lock Follows Remote Input
** When Remote Input switch is
closed, regardless of the current state of the lock, the lock will lock for
the duration of the Remote Input switch closure.
* Features 26, 27 & 28 will delay User Codes 12 and higher only (except 297, 298 and 299, and any Emergency Command enabled User).
** Features 30, 31 & 32 should be used with External DC Power unless feature is used for short a duration and infrequently (sustained closure of remote input or
Relay will drain batteries, and scheduled events will not occur during sustained closure of remote input). Sustained closure of remote input may affect proper
audit trail operation.
NOTE:
Enter
;
6
7
;
0
0
0
:
to delete all Relay Features added by Function 67 (identical to Function 68).
*** Feature 24, "One Time Access for Group 3 Users", allows the creation of multiple 'one time only' User Codes. When activated, an entry by a Group 3 User allows
entry only once, then user becomes disabled.
Note:
When the User Code is entered for the first time and access is granted, the Event Log will read "Entry" fol-
lowed by "User Disabled". If the User Code is entered a second time, access will be denied, and the Event Log will read "User Denied Access".
To Enable the Feature:
Enter Program Mode and enter the key sequence
;
6
7
;
2
4
:
.
To assign the selected User Codes to
Group 3:
For example, to assign User Number 15 to Group 3, press:
;
3
5
;
1
5
;
3
:
.
†
Emergency Commands are disabled until a download from DL-Windows is performed. If a Function 67 or 68 (Clear Relay) is performed, Emergency Commands
are turned off.
Enter
;
6
8
;
0
0
0
:
to delete all Relay Features added by Function 67.
4
Programming Functions (cont'd)
Ambush Function
1.
Connect relay to a device able to properly monitor dry contacts for an
Ambush
condition.
2.
Program the Relay for
Ambush Tripped
using Program Function 67(10) above.
3.
Set the Ambush Code using Program Function 66.
4.
When the Ambush Code is entered followed by a valid User Code, the relay will close for 2 seconds.
Notes:
The Ambush Code defaults to
99
. An error will sound if you try to program a new User Code starting with the Ambush Code.
•
Enable Emergency Commands
†
38. Emergency Commands Enable (default = ON)
39. User Lockout on Emergency (default = ON)