background image

OPERATES ON 12 OR 24 VOLTS AC/DC, AUTO SENSING

FULLY PROGRAMMABLE FROM THE KEYPAD

302 STAINLESS STEEL FACEPLATE WITH TAMPER-PROOF SCREWS

BLACK POWDER COATED DIE CAST ALUMINUM BACK BOX 

100 USER CODES WITH CODE LENGTHS FROM 4 TO 8 DIGITS

KEYS ARE BACKLIT FOR VISIBILITY IN DARK AREAS

DIE CAST METAL KEYS WITH AUDIBLE AND VISUAL KEY PRESS

TWO PROGRAMMABLE S.P.D.T. RELAY OUTPUTS

DOOR PROP OPEN ALARM, DOOR FORCED OPEN ALARM 

BUILT-IN TAMPER SWITCH, BUILT-IN BUZZER

REQUEST TO EXIT INPUT, DURESS OUTPUT, ANTI-TAILGATING FEATURE

RED, YELLOW AND GREEN LEDS INDICATE KEYPAD STATUS

LIFETIME LIMITED WARRANTY

MODEL KP-400

VANDAL RESISTANT & WEATHERPROOF

SELF-CONTAINED DIGITAL KEYPAD

ALARM CONTROLS CORPORATION

DEER PARK, NEW YORK

11729

DESIGNED FOR ACCESS CONTROL APPLICATIONS

Содержание KP-400

Страница 1: ...AS DIE CAST METAL KEYS WITH AUDIBLE AND VISUAL KEY PRESS TWO PROGRAMMABLE S P D T RELAY OUTPUTS DOOR PROP OPEN ALARM DOOR FORCED OPEN ALARM BUILT IN TAMPER SWITCH BUILT IN BUZZER REQUEST TO EXIT INPUT...

Страница 2: ...OCKS FOR 30 SECONDS RELAYS CAN BE SET FOR MOMENTARY OR LATCHING MODE ADJUSTABLE RELAY ON TIME FROM 1 TO 999 SECONDS KEYPAD BEEPER CAN BE SILENCED IF REQUIRED KEYPAD CAN BE PROGRAMMED FOR OUTPUT ANNUNC...

Страница 3: ...OLS CORPORATION 19 BRANDYWINE DRIVE P O BOX 280 DEER PARK NY 11729 WWW ALARMCONTROLS COM SELF CONTAINED DIGITAL VANDAL RESISTANT WEATHERPROOF ACCESS CONTROL KEYPAD MODEL KP 400 OPERATING INSTRUCTIONS...

Страница 4: ...S AC DC AUTO VOLTAGE SENSING ACTIVE CURRENT DRAW 100 MA MAX 12 V 120 MA MAX 24 V IDLE CURRENT DRAW 10 MA MAX 12 V 22 MA MAX 24 V OUTPUT 1 CONTACT RATING 5A 28 VDC OUTPUT 2 CONTACT RATING 1A 28 VDC REL...

Страница 5: ...ER CODE MULTIPLE REQUEST TO EXIT STATIONS CAN BE CONNECTED IN PARALLEL TO THESE TERMINALS LED INDICATORS RED ON WHEN OUTPUT 2 IS ACTIVE GREEN ON WHEN OUTPUT 1 IS ACTIVE YELLOW MONITORS POWER DRY CONTA...

Страница 6: ...1 TO 999 SECONDS 4 INTER LOCK CONTROL THE INTER LOCK CONTROL OUTPUT GOES TO GROUND WHEN THE DOOR IS OPEN IN ORDER TO DISABLE THE SECOND KEYPAD IN THE INTER LOCK SYSTEM O P 1 INHIB OUTPUT 1 INHIBIT TH...

Страница 7: ...2 BEEPS SUCCESSFUL CODE ENTRY 5 FLASHES 5 BEEPS FAULTY CODE ENTRY CONTINUOUS FLASHING CONTINUOUS TONE DAP JUMPER NOT REPLACED CONTINUOUS FLASHING NONE 1 FLASH IN 2 SEC INTERVAL NONE 1 LONG BEEP OUTPU...

Страница 8: ...LOWED To activate Keypad Initiation Mode enter then press the key The Yellow Led will flash twice and you will hear two beeps You are now in Keypad Initiation Mode 8 9 0 1 STEP 3 ENTERING THE USER COD...

Страница 9: ...D SILENT MODE To exit the Program Mode press the key The Keypad returns to normal operation The Keypad can be programmed with additional features by using the following op tions You have only 10 secon...

Страница 10: ...need the same number of digits To program the Keypad for Manual Mode press the keys then press the then press the key The Keypad is now in the Manual Mode PAGE 8 PAGE 7 CODE ENTRY MODES AUTO OR MANUA...