background image

ALARM CONTROLS CORPOR ATION

“QUALITY SECURITY EQUIPMENT SINCE 1971”

19 BRANDYWINE DRIVE, P.O. BOX 280, DEER PARK, NEW YORK 11729

1 800 645-5538  631 586-4220  FAX 631 586-6500

EMAIL: [email protected]   WWW.ALARMCONTROLS.COM

MODEL KP-400 DIGITAL KEYPAD 

FOR ACCESS CONTROL APPLICATIONS

SPECIFICATIONS 

OPERATING VOLTAGE: 12 OR 24 VOLTS AC/DC, AUTO SENSING
ACTIVE CURRENT DRAW : 100 MA. @ 12 VOLTS, 120 MA. @ 24 VOLTS
IDLE CURRENT: 10 MA. MAX. @ 12 VOLTS, 22 MA. MAX. @ 24 VOLTS
OUTPUT 1 CONTACT RATING: S.P.D.T.,  5A. @ 28 VDC/120 VAC
OUTPUT 2 CONTACT RATING: S.P.D.T., 1A @ 28 VDC/120 VAC
TAMPER SWITCH CONTACTS: N/C DRY CONTACTS, 50 MA. MAX.
OPERATING TEMPERATURE: -4F TO 158F,  ( -20C TO +70C )
AMBIENT HUMIDITY: 5 TO 95% RELATIVE HUMIDITY
ENVIROMENT: CONFORMS TO IP66 CODE, DUSTPROOF AND WATERPROOF FROM POWERFUL WATER SPRAY
EGRESS INPUT: NORMALLY-OPEN CONTACTS
100 USER CODES, OPERATES OUTPUT 1, CODE LENGTH FROM 4 TO 8 DIGITS 
10 USER CODES, OPERATES OUTPUT 2, CODE LENGTH FROM 4 TO 8 DIGITS  
KEYPAD LOCKOUT FEATURE, AFTER 10 FALSE CODE ENTRYS KEYPAD LOCKS FOR 30 SECONDS
RELAYS CAN BE SET FOR MOMENTARY OR LATCHING MODE
ADJUSTABLE RELAY ON TIME FROM 1 TO 999 SECONDS
KEYPAD BEEPER CAN BE SILENCED IF REQUIRED
KEYPAD CAN BE PROGRAMMED FOR OUTPUT ANNUNCIATION
DIE CAST METAL BACKLIT KEYS FOR VISIBILITY IN DARK AREAS
SURFACE MOUNT DIE CAST METAL BLACK POWDER COATED BACK BOX 

TYPICAL WIRING DIAGRAM

KEYPAD FEATURES

12/24V

AC/DC

12/24V

POWER

SUPPLY

OUTPUT 2

EG

IN

OUTPUT 1

N/C

N/O

C

N/C

N/O

C

+

MAGNETIC

LOCK

ELECTRIC

STRIKE

N/C TAMPER SWITCH

CAN PROVIDE A REMOTE ALARM

SIGNAL.

DOOR SENSOR INPUT

CONNECTED TO A N/C MAGNETIC

CONTACT MOUNTED ON THE DOOR WILL PROVIDE THE

FOLLOWING FUNCTIONS: 
DOOR AUTO RELOCK TO PREVENT “TAILGATING”

DOOR FORCED OPEN ALARM

DOOR PROPED OPEN ALARM

DOOR INTERLOCK, (MANTRAP), REQUIRES 2 KEYPADS

KEY ACTIVE OUTPUT

SWITCHES TO GROUND FOR 10

SECONDS WHEN A KEY IS PRESSED.  CAN BE USED     

FOR A REMOTE LED, BUZZER OR RELAY.

DURESS OUTPUT

SWITCHES TO GROUND WHEN A 

DURESS CODE IS ENTERED.  CAN BE USED FOR 

REMOTE SIGNALING.

OUTPUT 1 INHIBIT 

PREVENTS OUTPUT 1 AND EGRESS

BUTTON FROM OPERATING

INTERLOCK CONTROL OUTPUT 

THIS OUTPUT IS USED

TO TO CONTROL A SECOND KEYPAD IN A INTERLOCK

SYSTEM TO PREVENT BOTH DOORS FROM OPENING AT

THE SAME TIME.

Содержание KP-400

Страница 1: ...AS DIE CAST METAL KEYS WITH AUDIBLE AND VISUAL KEY PRESS TWO PROGRAMMABLE S P D T RELAY OUTPUTS DOOR PROP OPEN ALARM DOOR FORCED OPEN ALARM BUILT IN TAMPER SWITCH BUILT IN BUZZER REQUEST TO EXIT INPUT...

Страница 2: ...OCKS FOR 30 SECONDS RELAYS CAN BE SET FOR MOMENTARY OR LATCHING MODE ADJUSTABLE RELAY ON TIME FROM 1 TO 999 SECONDS KEYPAD BEEPER CAN BE SILENCED IF REQUIRED KEYPAD CAN BE PROGRAMMED FOR OUTPUT ANNUNC...

Страница 3: ...OLS CORPORATION 19 BRANDYWINE DRIVE P O BOX 280 DEER PARK NY 11729 WWW ALARMCONTROLS COM SELF CONTAINED DIGITAL VANDAL RESISTANT WEATHERPROOF ACCESS CONTROL KEYPAD MODEL KP 400 OPERATING INSTRUCTIONS...

Страница 4: ...S AC DC AUTO VOLTAGE SENSING ACTIVE CURRENT DRAW 100 MA MAX 12 V 120 MA MAX 24 V IDLE CURRENT DRAW 10 MA MAX 12 V 22 MA MAX 24 V OUTPUT 1 CONTACT RATING 5A 28 VDC OUTPUT 2 CONTACT RATING 1A 28 VDC REL...

Страница 5: ...ER CODE MULTIPLE REQUEST TO EXIT STATIONS CAN BE CONNECTED IN PARALLEL TO THESE TERMINALS LED INDICATORS RED ON WHEN OUTPUT 2 IS ACTIVE GREEN ON WHEN OUTPUT 1 IS ACTIVE YELLOW MONITORS POWER DRY CONTA...

Страница 6: ...1 TO 999 SECONDS 4 INTER LOCK CONTROL THE INTER LOCK CONTROL OUTPUT GOES TO GROUND WHEN THE DOOR IS OPEN IN ORDER TO DISABLE THE SECOND KEYPAD IN THE INTER LOCK SYSTEM O P 1 INHIB OUTPUT 1 INHIBIT TH...

Страница 7: ...2 BEEPS SUCCESSFUL CODE ENTRY 5 FLASHES 5 BEEPS FAULTY CODE ENTRY CONTINUOUS FLASHING CONTINUOUS TONE DAP JUMPER NOT REPLACED CONTINUOUS FLASHING NONE 1 FLASH IN 2 SEC INTERVAL NONE 1 LONG BEEP OUTPU...

Страница 8: ...LOWED To activate Keypad Initiation Mode enter then press the key The Yellow Led will flash twice and you will hear two beeps You are now in Keypad Initiation Mode 8 9 0 1 STEP 3 ENTERING THE USER COD...

Страница 9: ...D SILENT MODE To exit the Program Mode press the key The Keypad returns to normal operation The Keypad can be programmed with additional features by using the following op tions You have only 10 secon...

Страница 10: ...need the same number of digits To program the Keypad for Manual Mode press the keys then press the then press the key The Keypad is now in the Manual Mode PAGE 8 PAGE 7 CODE ENTRY MODES AUTO OR MANUA...