Alarm Controls Corporation KP-400 Скачать руководство пользователя страница 9

The Keypad beeper can be silenced if required.  the beeper will not sound when the keys are

pressed.  
For silent operation press the            keys then press       key then press the       key. 

The keypad is now in the silent mode. 

To restore to audible keypad operation press the             keys then press the       key then

press the        key.  

The keypad is now in the audible mode.

If the door is left open longer than the pre-set time the Keypad will generate a door propped

Open Alarm until the door is closed.  
To program the Door Propped Open Alarm press the       key then enter the door open time

1 to 999 seconds then press the       key. 

The Door Propped Open Alarm is now enabled.

To disable the Door Propped Open Alarm press the        key then press the       key then press

the      key. 

The Door Propped Open Alarm is now disabled.

The Keypad will generate a a door forced open alarm instantly if the door is forced open with-

out a valid User Code or egress input.  The alarm will last for 60 seconds. 

To program the Door Forced Open Alarm press the             keys then press the       key then

press the       key.  

The Door Forced Open Alarm is now enabled.

To disable the Door Forced Open Alarm press the             keys the press the       key then

press the        key.  

The Door Forced Open Alarm is now disabled.

Output 2 in Momentary Mode

Press the            keys then enter the relay “on” time.  This time can be from 1 to 999 sec.

then press the       key.  The Yellow Led will flash twice and you will hear two beeps.  

The

Momentary Mode for Output 2 has been entered. 

You must be in the Program Mode.

Output 2 in Latching Mode

Press the             keys.  Follow the directions above to enter Output 2 Latching Mode.

You must be in the Program Mode. 

5 0

5 1

PAGE 6

PAGE 9

TO EXIT THE PROGRAM MODE

PROGRAMMING OPTIONS

FALSE CODE LOCKOUT

DOOR FORCED OPEN ALARM

DOOR PROPPED OPEN ALARM

KEYPAD SILENT MODE

#

To exit the Program Mode press the       key.  The Keypad returns to normal operation.

*

The Keypad can be programmed with additional features by using the following op-

tions.

You have only 10 seconds between key entries otherwise the keypad will return to the

Program Mode.  

The Keypad must be in the Program Mode to install these options. 

The Keypad can be disabled for 15 minutes after 5 successive false code entries by entering

the following: Press            keys then press the        key then press        key.  The Keypad Lock

out in now enabled.  To disable the Keypad Lockout press the            keys then press the  

keys then press the        key.  

The Keypad Lockout feature is now disabled.

7 2

8 0

8 0

8 3

8 3

0 0

7 6

5

1

0

0

0

1

9

9

#

#

#

#

#

#

#

#

BASIC WIRING OF A MAGNETIC LOCK AND ELECTRIC DOOR STRIKE

WITH DOOR LOCK INHIBIT

MODEL KP-400

WARNING

Make sure nobody is inside the premises

before the Door Lock Inhibit function is

turned on.  The Door locks when the Door

Lock Inhibit function is turned on and can

only be turned off with the Inhibit

Authorization Code.  Keep this Code in a

secure place.

WHEN WIRING A MAGNETIC LOCK USE THE N/C RELAY CONTACTS.
WHEN WIRING AN ELECTRIC DOOR STRIKE.

The 1N4004 diode must be connected to the Electric Door Strike as shown in the dia-
gram above to prevent arcing across the Keypad relay contacts.  The diode is not re-
quired when powering the Electric Door Strike on AC current.  Use the N/O Output when
operating the Electric Strike in the fail-secure mode.  Use the N/C Output when operat-
ing the Electric Strike in the fail-safe mode.
Use Output 2 for the Authorization control.  User Code 2 is used to block the operation

of the Magnetic Lock or Electric Strike when when privacy is required.   

Only User Code 2 will operate the Keypad. 
User Code 1 will not operate the Keypad. 

MAGNETIC LOCK

OR

ELECTRIC 

STRIKE

USE N/O

CONTACTS

OF REQUEST

TO EXIT STATION

MODEL TS-2

SHOWN

12 OR 24 VOLT

AC OR DC

POWER 

SUPPLY 

AC CAN ONLY BE

USED WITH AC

ELECTRIC STRIKES

Содержание KP-400

Страница 1: ...AS DIE CAST METAL KEYS WITH AUDIBLE AND VISUAL KEY PRESS TWO PROGRAMMABLE S P D T RELAY OUTPUTS DOOR PROP OPEN ALARM DOOR FORCED OPEN ALARM BUILT IN TAMPER SWITCH BUILT IN BUZZER REQUEST TO EXIT INPUT...

Страница 2: ...OCKS FOR 30 SECONDS RELAYS CAN BE SET FOR MOMENTARY OR LATCHING MODE ADJUSTABLE RELAY ON TIME FROM 1 TO 999 SECONDS KEYPAD BEEPER CAN BE SILENCED IF REQUIRED KEYPAD CAN BE PROGRAMMED FOR OUTPUT ANNUNC...

Страница 3: ...OLS CORPORATION 19 BRANDYWINE DRIVE P O BOX 280 DEER PARK NY 11729 WWW ALARMCONTROLS COM SELF CONTAINED DIGITAL VANDAL RESISTANT WEATHERPROOF ACCESS CONTROL KEYPAD MODEL KP 400 OPERATING INSTRUCTIONS...

Страница 4: ...S AC DC AUTO VOLTAGE SENSING ACTIVE CURRENT DRAW 100 MA MAX 12 V 120 MA MAX 24 V IDLE CURRENT DRAW 10 MA MAX 12 V 22 MA MAX 24 V OUTPUT 1 CONTACT RATING 5A 28 VDC OUTPUT 2 CONTACT RATING 1A 28 VDC REL...

Страница 5: ...ER CODE MULTIPLE REQUEST TO EXIT STATIONS CAN BE CONNECTED IN PARALLEL TO THESE TERMINALS LED INDICATORS RED ON WHEN OUTPUT 2 IS ACTIVE GREEN ON WHEN OUTPUT 1 IS ACTIVE YELLOW MONITORS POWER DRY CONTA...

Страница 6: ...1 TO 999 SECONDS 4 INTER LOCK CONTROL THE INTER LOCK CONTROL OUTPUT GOES TO GROUND WHEN THE DOOR IS OPEN IN ORDER TO DISABLE THE SECOND KEYPAD IN THE INTER LOCK SYSTEM O P 1 INHIB OUTPUT 1 INHIBIT TH...

Страница 7: ...2 BEEPS SUCCESSFUL CODE ENTRY 5 FLASHES 5 BEEPS FAULTY CODE ENTRY CONTINUOUS FLASHING CONTINUOUS TONE DAP JUMPER NOT REPLACED CONTINUOUS FLASHING NONE 1 FLASH IN 2 SEC INTERVAL NONE 1 LONG BEEP OUTPU...

Страница 8: ...LOWED To activate Keypad Initiation Mode enter then press the key The Yellow Led will flash twice and you will hear two beeps You are now in Keypad Initiation Mode 8 9 0 1 STEP 3 ENTERING THE USER COD...

Страница 9: ...D SILENT MODE To exit the Program Mode press the key The Keypad returns to normal operation The Keypad can be programmed with additional features by using the following op tions You have only 10 secon...

Страница 10: ...need the same number of digits To program the Keypad for Manual Mode press the keys then press the then press the key The Keypad is now in the Manual Mode PAGE 8 PAGE 7 CODE ENTRY MODES AUTO OR MANUA...

Отзывы: