The Keypad beeper can be silenced if required. the beeper will not sound when the keys are
pressed.
For silent operation press the keys then press key then press the key.
The keypad is now in the silent mode.
To restore to audible keypad operation press the keys then press the key then
press the key.
The keypad is now in the audible mode.
If the door is left open longer than the pre-set time the Keypad will generate a door propped
Open Alarm until the door is closed.
To program the Door Propped Open Alarm press the key then enter the door open time
1 to 999 seconds then press the key.
The Door Propped Open Alarm is now enabled.
To disable the Door Propped Open Alarm press the key then press the key then press
the key.
The Door Propped Open Alarm is now disabled.
The Keypad will generate a a door forced open alarm instantly if the door is forced open with-
out a valid User Code or egress input. The alarm will last for 60 seconds.
To program the Door Forced Open Alarm press the keys then press the key then
press the key.
The Door Forced Open Alarm is now enabled.
To disable the Door Forced Open Alarm press the keys the press the key then
press the key.
The Door Forced Open Alarm is now disabled.
Output 2 in Momentary Mode
Press the keys then enter the relay “on” time. This time can be from 1 to 999 sec.
then press the key. The Yellow Led will flash twice and you will hear two beeps.
The
Momentary Mode for Output 2 has been entered.
You must be in the Program Mode.
Output 2 in Latching Mode
Press the keys. Follow the directions above to enter Output 2 Latching Mode.
You must be in the Program Mode.
5 0
5 1
PAGE 6
PAGE 9
TO EXIT THE PROGRAM MODE
PROGRAMMING OPTIONS
FALSE CODE LOCKOUT
DOOR FORCED OPEN ALARM
DOOR PROPPED OPEN ALARM
KEYPAD SILENT MODE
#
To exit the Program Mode press the key. The Keypad returns to normal operation.
*
The Keypad can be programmed with additional features by using the following op-
tions.
You have only 10 seconds between key entries otherwise the keypad will return to the
Program Mode.
The Keypad must be in the Program Mode to install these options.
The Keypad can be disabled for 15 minutes after 5 successive false code entries by entering
the following: Press keys then press the key then press key. The Keypad Lock
out in now enabled. To disable the Keypad Lockout press the keys then press the
keys then press the key.
The Keypad Lockout feature is now disabled.
7 2
8 0
8 0
8 3
8 3
0 0
7 6
5
1
0
0
0
1
9
9
#
#
#
#
#
#
#
#
BASIC WIRING OF A MAGNETIC LOCK AND ELECTRIC DOOR STRIKE
WITH DOOR LOCK INHIBIT
MODEL KP-400
WARNING
Make sure nobody is inside the premises
before the Door Lock Inhibit function is
turned on. The Door locks when the Door
Lock Inhibit function is turned on and can
only be turned off with the Inhibit
Authorization Code. Keep this Code in a
secure place.
WHEN WIRING A MAGNETIC LOCK USE THE N/C RELAY CONTACTS.
WHEN WIRING AN ELECTRIC DOOR STRIKE.
The 1N4004 diode must be connected to the Electric Door Strike as shown in the dia-
gram above to prevent arcing across the Keypad relay contacts. The diode is not re-
quired when powering the Electric Door Strike on AC current. Use the N/O Output when
operating the Electric Strike in the fail-secure mode. Use the N/C Output when operat-
ing the Electric Strike in the fail-safe mode.
Use Output 2 for the Authorization control. User Code 2 is used to block the operation
of the Magnetic Lock or Electric Strike when when privacy is required.
Only User Code 2 will operate the Keypad.
User Code 1 will not operate the Keypad.
MAGNETIC LOCK
OR
ELECTRIC
STRIKE
USE N/O
CONTACTS
OF REQUEST
TO EXIT STATION
MODEL TS-2
SHOWN
12 OR 24 VOLT
AC OR DC
POWER
SUPPLY
AC CAN ONLY BE
USED WITH AC
ELECTRIC STRIKES