background image

Interlogix part number: 600-9400-IMAG 
Alarm.com part number: ADC-IS-100-LP

 

Alarm.com Image Sensor 

 

 Installation Guide

 

 

   

                    

 

1                                                                                                            Copyright © 2012 Alarm.com. All rights reserved. 

 

 

Rev 3.2 

 

                

             

 

  

PRODUCT SUMMARY 

The Image Sensor is a pet immune PIR (passive infrared) motion detector with a built-in 
camera. The sensor is designed to capture images during alarm or non-alarm events 
when motion is detected.  Users can also initiate image capture on-demand to  

Peek-In

 on their property. Images are stored locally and uploaded either automatically 

when motion is captured during alarm events or manually when requested by the user. 
Once uploaded, images are available for viewing on the Alarm.com Website or an 
Alarm.com Smart phone app. The sensor is battery powered, all wireless and simple to 
install and operate. Both an Alarm.com module and subscription to an Alarm.com service 
plan are required. 

 

Highlighted Features 

  Battery operated  

  Communicates wirelessly to the security control panel 

  35 feet by 40 feet detection coverage area 

  Configurable PIR sensitivity and pet immunity settings  

  Image: QVGA 320x240 pixels  

  Color Images (except in night vision) 

  Night vision image capture with infrared flash (black & white) 

  Tamper detection, walk test mode, supervision 

  

Service Plan Options 

Image capture features require either an Alarm.com Basic or Advanced

 

Interactive Service 

Plan and one of the following Image Sensor add-ons: 

 

Image Sensor Alarms

- Includes upload of images from alarm events only. 

 

Image Sensor Plus

- Includes upload of images from alarm events 

and

 non-alarm 

events. User can configure 

Daily View

 schedules to receive images automatically each 

day or 

Peek-In

 to initiate an on-demand image capture immediately, or when the next 

motion occurs. Users can also request images that are captured automatically while the 
system is 

Armed Away

 or following a 

Disarm

 from an 

Armed Away

 state. Up to 40 

captured events can be uploaded per month. Additional image uploads may be added 
in increments of 20 at an additional charge. 

HARDWARE COMPATIBILITY  

 

Security Control Panel: 

Interlogix Simon XT v1.3 or higher or XTi v 1.0 or higher

 

 

Alarm.com Module

 Simon XT Module with firmware 146 or higher (XTi requires 

module with firmware 151 or higher) 

 

Required Daughterboard: 

Image Sensor daughterboard (attached to compatible 

Alarm.com module) 

 

Available Zones:  

One zone per Image Sensor installed.  On the Simon XT only, one 

additional zone is required for the required daughterboard. Up to three Image Sensors 
may be added per system.

 (Note: The Alarm.com GSM Module V4 is required to use 

both Image Sensor and emPower

™.) 

 

HARDWARE INSTALLATION

 

1. 

Create Alarm.com Customer Account

-

 Select service plan (including Image Sensor 

add-on) and register the Alarm.com module serial number on the Dealer Website. 

 

2.  Install Image Sensor Daughterboard

-

 Locate the connector on the back of the 

daughterboard. Remove the green backing from the daughterboard mounting adhesive.  
While the module is powered down, align the daughterboard and module connector.  
Press to secure. 

(NOTE: Verify module compatibility before attaching. Once attached, 

daughterboard is difficult to remove and removing may damage hardware.)

 

 
 

 

 
 
 
 
 

3.  Install Alarm.com Module Inside Control Panel

 

4. 

FOR SIMON XT ONLY, Connect Daughterboard Alarm Wire-

  

On the XTi panel, the  

blue alarm hardwire is not required and should not be connected.  For XTi panels, skip 
to step 5.  When using the Simon XT panel, you must connect the included blue wire 
from 

the “HW” hardwire output located on the daughterboard (use “HW” not “C”) to the 

“HW2 IN” (terminal 3) slot on the Simon XT panel to enable local alarm activations. 
Once an Image Sensor has been enrolled into the panel, a hardwire zone will 
automatically be programmed as “Sensor 39: ISHW.” To ensure alarms are tripped 
properly on Image Sensors according to their enrolled group, the hardwire sensor group 
is automatically configured. Do NOT alter the sensor group of Sensor 39 ISHW. 

(Note: On the Simon XT, the panel scr

een will display “Sensor 39: ISHW Alarm” 

regardless of which Image Sensor tripped the alarm. The Alarm.com Website & 
notifications, and the central station report will indicate the specific Image Sensor that 
tripped the alarm.) 

 
 

5.  Route Daughterboard Antenna

- It is important to be sure that daughterboard antenna 

is pulled away from the Alarm.com module.  Follow the panel-specific antenna routing 
guidelines to optimize sensor range.   

Simon XT-

 

  The antenna should be pulled down off the Alarm.com module and routed 

in a “J” shape to the left towards the corner of the panel (when looking at the panel from 
behind.  

 

      

                              

 

Simon XTi-

 

Bend the antenna at a 90

°

 angle ¼ of an inch from the edge of the 

daughterboard.  The daughterboard antenna should rest inside the panel

’s plastic 

casing parallel to the panel. 

 

 

 

6.  Register Module and Test

-

 

Power the panel and initiate a comm-test to ensure the 

Alarm.com module is properly installed and communicating with the Alarm.com NOC. 

 

7.  Enroll Sensor in Panel

-

  

Simon XT-

 

To enroll the sensor on a Simon XT, follow these steps at the control panel:

 

a. 

Begin with the batteries removed from the sensor.

 

b. 

On the panel, scroll until the screen displays “System Programming,” and press OK.

 

c. 

Enter the installer code (default 4-3-2-1), and press OK.

 

d. 

S

croll up to “Interactive Services,” press OK.

 

e. 

Scroll down to “Image Sensor Setup,” press OK.

 

f. 

Scroll to “Image Sensor Learn Mode,” press OK. The screen should display “Power     
up or reset I.S. now.

 

g. 

Insert the batteries into the sensor.  Wait (approximately 20 seconds) for the control 
panel screen to display: 

“I.S. [x] Added as Sensor [y].” The LED on the sensor will 

turn solid for ~5 seconds once the sensor has enrolled. 

h. 

Perform another panel comm-test to be sure that Alarm.com receives the updated 
device equipment list.  This will speed up the sensor initialization process.  
 

The sensor is now learned into the panel. Sensors are enrolled in group 17 by default. 
To change the sensor group, use the 

Sensors

 menu in System Programming. Image 

Sensors may be enrolled in groups 15, 17, 20, or 25. (No chime issued for group 25.) 
On the Simon XT ,a mix of sensor groups 15/17 and 20 are not supported. If Image 
Sensors are in group 15 or 17, they cannot also be in group 20, and vice versa. After 
enrollment, be sure to keep the sensor and panel powered so the sensor can complete 
an initialization process with the Alarm.com Network Operations Center. This process 
will take several minutes. Images cannot be captured until initialization is complete.   

 

Daughterboard 
Antenna 

Module 

DB 

Bottom of Simon XTi Panel 

 

Silver shield with 
Alarm.com logo 

White label 
with info 

Insert blue alarm hardware into 
HW and push to secure 

Top of Image Sensor 
Daughterboard 

Bottom of Simon XT Panel 

Blue Alarm Hardwire 
from Daughterboard 

Connect to “HW 2IN” 

(Terminal 3) 

Отзывы: