53
3 Preparation for the Dive
III Uwatec
®
Aladin
®
Air Z O
2
English
III
– In extremely pure freshwater, it is possible that the Aladin
®
Air Z O
2
will not
automatically activate the dive-mode.
3.2 Preparation for a Dive with pressure transmitter
The following description of the preparation of a dive is based on the assumption that the pressure trans-
mitter is mounted correctly at the HP-outlet of the regulator (see pages 36, 37) and that it is paired with
Aladin
®
Air Z O
2
(see page 38).
If the Aladin
®
Air Z O
2
pressure transmitter is not correctly mounted or is not
correctly paired, it will not perform properly and serious injury or death may
result.
1. Mount regulator with pressure transmitter on tank.
2. Check the reserve valve of your tank, the reserve valve must be open.
If a reserve or “J“-type valve is used, the valve must be in the open (down)
position for the Aladin
®
Air Z O
2
to work correctly.
3. Switching on Aladin
®
Air Z O
2
manually:
Bridge contacts B and E
with moistened fingers. Check test display: are
all displays lit?
4. Open valve (pressure transmitter switches on automatically).
DO NOT FLY
DIVEPLAN
LOGBOOK
CNS O
2
LIMIT
O
2
% MIX
NO STOP
DECOSTOP
DESATURATION
S
L
O
W
SPEED
%
depth
dive time
deco info
max. depth
tank data
psi
bar
CAL O
2
O
2
%
ft
h
m
h