AL-MEISTER ALM3220 Instruction Manual <Rev.2>
Page 46 of 50
8. CLEANING AND LUBRICATING THE HEAT
CHAMBERS
With continuous use the heat chambers will accumulate
adhesive and dirt. It is recommended that you periodically
inspect them for adhesive build-up. Use DryLam Cleaning Kit
(part number CLKIT), which contains Xenit Cleaner and a
sponge, for removal of any adhesive build up.
Other suggested solvents are
Rubbing alcohol (isopropyl 70%, or higher)
Goof-Off®,
Acetone
Poly-Off®