Maintenance

Check the operational capability of the Ajax security system on a regular basis. Clean the hub
body from dust, spider webs and other contaminants as they appear. Use soft dry napkin
suitable for equipment maintenance.

Do not use any substances containing alcohol, acetone, gasoline and other active solvents for
cleaning the hub.

The package includes

Technical Speci cations

Classi cation

Security system control panel with Ethernet, Wi-Fi, and
dual SIM card support

Support of detectors with photo veri cation of alarms

Available

Number of connected devices

Up to 200

Number of connected ReX

Up to 5

Number of security groups

Up to 25

Number of users

Up to 200

Video surveillance

Up to 100 cameras or DVRs

Number of rooms

Up to 50

Number of scenarios

Up to 64

(Reactions by arming and disarming are not included in
the overall limit of the hub’s scenarios)

Central Monitoring Station communication protocols

Contact ID, SIA (DC-09)

Power supply

110-240 V with pre-installed battery 
6 V with alternativ

 power supply 

Energy consumption from the 110-240 V grid — 10 W

Built-in back-up battery

Li-Ion 3 А·h 
Ensures up to 15 hours of operation when using SIM card
only

Energy consumption from the grid

Up to 10 W

Tamper proof

Available, tamper

Operating frequency band

868.0–868.6 MHz or 868.7–869.2 MHz, depending on the
sales region

RF output power

10.4 mW (max 25 mW)

Radio signal range

Up to 2000 m

Communication channels

2 SIM cards

Wi-Fi (802.11 b/g/n)

Ethernet

Operating temperature range

From –10°C to +40°C

Operating humidity

Up to 75%

Size

163 × 163 × 36 mm

Weight

367 g

Outside the premises (outdoors).

Nearby or inside any metal objects or mirrors causing attenuation and screening of the
signal.

In places with high radio interference level.

Close to radio interference sources: less than 1 meter from the router and power cables.

Inside any premises with the temperature and humidity beyond the range of permissible
limits.

How to replace hub battery

1. Hub 2 Plus

2. SmartBracket mounting panel

3. Power cable

4. Ethernet cable

5. Installation kit

6. Starter pack — not available in all countries

7. Quick Start Guide

CMS software supporting visual alarms
veri cation

6V PSU

2G (GSM900/DCS1800 (B3/B8))

3G (WCDMA 850/900/2100 (B1/B5/B8))

LTE (FDD B1/B3/B5/B7/B8/B20/B28)

Содержание Hub 2 Plus

Страница 1: ...ection information is exchanged with the hub via an encrypted channel Connect all communication channels to ensure a more reliable connection with Ajax Cloud and to secure against interruptions in the...

Страница 2: ...pressing of the or by schedule A scenario can be created remotely in the Ajax app LED indication The Ajax logo on the hub front lights up red white or green depending on the status of the power supply...

Страница 3: ...d connected to Ajax Cloud If the Ethernet connection is not established automatically disable proxy and MAC address ltration and activate DHCP in the router settings The hub will automatically receive...

Страница 4: ...percentage Lid Status of the tamper that responds to hub dismantling External power External power supply connection status Connection Connection status between the hub and Ajax Cloud Cellular Data Th...

Страница 5: ...avatar or name go to Room settings by pressing Connection of detectors and devices The hub doesn t support and integration modules When adding a hub to your account using the step by step guidance yo...

Страница 6: ...to add new users to the hub Ethernet settings for wired Internet connection Ethernet allows you to enable and disable Ethernet on the hub DHCP Static selection of the type of the hub IP address to re...

Страница 7: ...ngs in the hub Incoming the amount of data received by the hub Displayed in KB or MB Outgoing the amount of data sent by the hub Displayed in KB or MB USSD code enter the code that is used to check th...

Страница 8: ...n the range of 12 to 300 s 36 s by default Number of undelivered packets to determine connection failure a counter of undelivered packets 8 packets by default Service is a group of hub service setting...

Страница 9: ...button is pressed When the function is active the hub activates the connected sirens if the panic button was pressed in the Ajax app You can disable the sirens reaction when pressing the panic button...

Страница 10: ...rm has been registered previously For arming the system should be restored by an authorized user or PRO user The types of alarms that require system restore are de ned when con guring the function The...

Страница 11: ...is available only for the SIA protocol Object number the number of an object in the monitoring station hub IP address and Port are settings of the primary IP address and port of the security company...

Страница 12: ...ferring devices and settings from another hub Keep in mind that you are in the settings of the hub on which you want to import data Learn more about data import Unpair hub removes your account from th...

Страница 13: ...e security system Implement all potential measures to improve the signal quality At the very least relocate the hub as even repositioning by 20 cm can signi cantly improve the signal reception If low...

Страница 14: ...rgy consumption from the 110 240 V grid 10 W Built in back up battery Li Ion 3 h Ensures up to 15 hours of operation when using SIM card only Energy consumption from the grid Up to 10 W Tamper proof A...

Страница 15: ...s after the purchase and does not apply to the bundled rechargeable battery If the device does not function properly we recommend that you rst contact the support service as technical issues can be re...

Отзывы: