35
<FM Adjustment>
For adjusting FM, do wiring and connection as in the following.
Standard Signal Generator
i
Rch
Lch
SET
TP
GND
Connect to the respective measuring device
9. Tracking Adjustment (FM)
Requirement
Measuring device: Millivoltmeter
Test Point: Lch, Rch, GND
Adjustment Point: L901, L902, L904, L905
(1) Adjust the S.S.G setting to 108.0 MHz, 75 kHz variation and reduce the output level all the way.
(2) Adjust L901, L902, L904, L905 until the value of millivoltmeter reaches the maximum.
(3) Adjust the S.S.G setting to 98.0 MHz, 75 kHz variation, and 66 dBuV for the output level.
(4) Check that the test point voltage is below 13 dBuV.
10. Auto Stop Check (FM)
Requirement
(1) Adjust the S.S.G setting to 98.0 MHz, 75 kHz variation, and 40 dBuV for the output level.
(2) Activate the tuner search function, and check that there is reception of 98.0 MHz.
CH2
CH1
GND
Lch
Rch
GND
AC MILLIVOLTMETER
All manuals and user guides at all-guides.com
Содержание XR-EM70
Страница 12: ...12 SCHEMATIC DIAGRAM 1 MAIN 1 2 PHONE OPTICAL HEAD All manuals and user guides at all guides com...
Страница 13: ...13 SCHEMATIC DIAGRAM 2 MAIN 2 2 AMP SECTION All manuals and user guides at all guides com...
Страница 18: ...18 SCHEMATIC DIAGRAM 4 CD CD DRIVE CD LOAD All manuals and user guides at all guides com...
Страница 20: ...20 SCHEMATIC DIAGRAM 5 TUNER All manuals and user guides at all guides com...
Страница 22: ...22 SCHEMATIC DIAGRAM 6 PT All manuals and user guides at all guides com...
Страница 24: ...24 IC BLOCK DIAGRAM All manuals and user guides at all guides com...
Страница 25: ...25 All manuals and user guides at all guides com...