PREPARE WINDOW FOR INSTALLATION
WINDOW REQUIREMENTS:
1. These instructions and installation parts are for a standard double-hung window. It can be installed with our
without the expandable panels. Make sure the opening is large enough for the unit size. Modify accordingly for
other types of windows.
9
14.5” (37cm)
23”-36” (59-92cm)
Min. Height
Min. Width
Max. Width
Inches 14.5”
23”
36”
CM
37cm 59cm 92cm
2. The unit must be installed within 122cm (4’) from a wall grounded outlet.
3. All supporting parts must be fixed to solid wood, masonry or metal.
4. Clear out the area where the unit is installed; air inlets and outlets must be free at all times. The rear of the unit
must be outdoors, not inside a building, a garage or other closed areas
WARNING: This product is a WINDOW AIR CONDITIONER. As such, a standard single hung or double
hung window is required for proper installation. Non-window installations, including using sleeves, holes
in the walls, and other installations are not recommended.
WINDOW CLEARANCE:
Important:
Proper clearance enhances the cooling efficiency of the unit and prevents heat radiation from the
condenser. If the air conditioner is blocked by the storm window, remove the storm window. If it is not possible, to
make sure the unit will drain properly, fix a piece of wood to the stool in order to allow the air conditioner to tilt
toward outside.
SIZE OF WINDOW PIECE:
WIDTH LENGTH
THICKNESS
1.5”/ 3.7cm Long enough to fit
inside window
frame
Place a piece of wood on stool to make it ½” (1.3cm) higher than the top
of the storm window frame. Ensure drain holes of storm window frame
are not blocked by caulking or paint.
1½” MIN
(38mm)