5-2
PERFORMANCE DATA & PRESSURE CURVES
SM PNXDCI 1-A.1 GB
5.1.3
Heating Capacity (kW) - Run Mode)
ID COIL ENTERING AIR DB TEMPERATURE [
0
C]
OD COIL ENTERING
AIR DB/WB
TEMPERATURE [
0
C]
DATA
15
20
25
-15/-16
TC
1.55
1.32
1.10
PI
0.58
0.62
0.66
-10/-12
TC
2.04
1.82
1.60
PI
0.66
0.70
0.74
-7/-8
TC
2.41
2.19
1.97
PI
0.71
0.75
0.80
-1/-2
TC
2.60
2.38
2.15
PI
0.74
0.78
0.82
2/1
TC
2.72
2.50
2.28
PI
0.76
0.80
0.84
7/6
TC
3.62
3.40
3.18
PI
0.79
0.83
0.87
10/9
TC
3.81
3.59
3.36
PI
0.80
0.86
0.89
15/12
TC
4.00
3.78
3.55
PI
0.82
0.86
0.90
15-24
TC
85 - 105 % of nominal
(Protection Range)
PI
80 - 120 % of nominal
LEGEND
TC –
Total Heating Capacity, kW
PI – Power Input, kW
WB – Wet Bulb Temp., (
o
C)
DB – Dry Bulb Temp., (
o
C)
ID – Indoor
OD –
Outdoor
5.1.4
Capacity Correction Factors
Heating Capacity Ratio Vs. Outdoor Temperature
0.40
0.50
0.60
0.70
0.80
0.90
1.00
1.10
1.20
-15
-10
-5
0
5
10
15
Outdoor WB Temperature [ºC]
Ca
p
ac
it
y Ra
ti
o
n